Characterization of Denitrifier Community in Independent Anoxic Reactor Using Modified BAF Process (Modified BAF 공정을 이용한 독립적인 무산소조에서 탈질미생물 군집의 특성)

  • Park, Jeung-Jin;Jeung, Young-Rok;Yu, Jae-Cheul;Hur, Sung-Ho;Choi, Won-Seok;Byun, Im-Gyu;Lee, Tae-Ho;Park, Tae-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.752-756
    • /
    • 2006
  • The independent anoxic reactor was introduced in biological aerated filters as the regulation of water quality requirement, especially total nitrogen, had been strengthened. The process studied in this work was upflow $Biobead^{(R)}$ process which was used commercial invented for removal of organic materials and nitrification. For the purpose of evaluating the independent anoxic reactor, PCR-DGGE, of the molecular biological methods, was performed. Two types of nitrite reductase genes were selected. One is nirS represented cytocrome $cd_1$ nitrite reductase gene and the other is nirK represented Cu-containing nitrite reductase gene. Denitrifier community in the independent anoxic reactor was analyzed with PCR-DGGE using these two denitrifying functional genes. As the result of the PCR, only nirS gene was detected between nirS and nirK. With the result of the DGGE, specific bands became strong, as the operating days were longer, nitrate loading rate was increased. otherwise those of the initial activated sludge showed various bands. In the consequence of the sequence of DGGE bands, various denitrifiers were sequenced in the initial activated sludge, while specific denitrifiers like alcaligenes faecalis were predominant in the anoxic reactor. Consequently, introduction of the independent anoxic reactor made it possible to achieve 96% denitrification efficiency, and was proper for the modification of BAF process.

Evaluation of Kinetic Constant and Effect of Effluent Recycling in Wastewater Treatment from Fisheries Processing Plant using EMMC Process (EMMC공정을 이용한 수산물 가공공장 폐수처리에서 동력학적 인자 평가와 유출수반송의 영향)

  • Jeong, Byung-Gon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • EMMC(Entrapped Mixed Microbial Cell) process which is a kind of active cell immobilizing method was applied to treat fisheries processing wastewater biologically. Kinetic constants were calculated for organic and nitrogen removal and effect of effluent recycling on system performance was evaluated also. Yield coefficient, Y showed relatively low value compared with Y value obtained from conventional activated sludge process. It means that EMMC process can reduce amount of excess sludge significantly compared with conventional activated sludge process. Endogenous respiration coefficient $k_e$ of EMMC process also showed relatively low value compared with that of conventional activated sludge process. Yield coefficient Y, endogenous respiration coefficient $k_e$ and half saturation constant $k_s$ obtained from EMMC process in terms of nitrification were compared with reported value from literature based on suspended growth nitrification system. The value of Y obtained from this study has no difference compared with values obtained from literature review and $k_e$ of this study was low but $k_s$ of this study was high compared than values obtained from suspended growth nitrification system. To evaluate the effect of internal recycling on system performance, system was operated with internal recycling ratio of 1.5Q, 2.0Q, 2.5Q and 3.0Q. increase of internal recycling ratio effect more greatly on improvement of denitrification efficiency than that of nitrification efficiency. Accordingly, optimization of internal recycling ratio has to be based on improvement of anoxic reactor performance.

  • PDF

Characterizations of Denitrifying Polyphosphate-accumulating Bacterium Paracoccus sp. Strain YKP-9

  • Lee, Han-Woong;Park, Yong-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.12
    • /
    • pp.1958-1965
    • /
    • 2008
  • A denitrifying polyphosphate-accumulating bacterium (YKP-9) was isolated from activated sludge of a 5-stage biological nutrient removal process with step feed system. This organism was a Gram-negative, coccus-shaped, facultative aerobic chemoorganotroph. It had a respiratory type of metabolism with oxygen, nitrate, and nitrite as terminal electron acceptors. The 16S rRNA gene sequence of strain YKP-9 was most similar to the 16S rRNA gene sequence of Paracoccus sp. OL18 (AY312056) (similarity level, 97%). Denitrifying polyphosphate accumulation by strain YKP-9 was examined under anaerobic-anoxic and anaerobic-oxic batch conditions. It was able to use external carbon sources for polyhydroxyalkanoates(PHA) synthesis and to release phosphate under anaerobic condition. It accumulated polyphosphate and grew a little on energy provided by external carbon sources under anoxic condition, but did neither accumulate polyphosphate nor grow in the absence of external carbon sources under anoxic condition. Cells with intracellular PHA cannot accumulate polyphosphate in the absence of external carbon sources under anoxic condition. Under oxic condition, it grew but could not accumulate polyphosphate with external carbon sources. Based on the results from this study, strain YKP-9 is a new-type denitrifying polyphosphate-accumulating bacterium that accumulates polyphosphate only under anoxic condition, with nitrate and nitrite as the electron acceptors in the presence of external carbon sources.

Integrated Evaluation of Advanced Activated Sludge Processes Based on Mathematical Model and Fuzzy Inference (수학적 모델 및 퍼지 추론에 의한 고도 활성슬러지 공정의 통합 평가)

  • Kang, Dong-Wan;Kim, Hyo-Su;Kim, Ye-Jin;Choi, Su-Jung;Cha, Jae-Hwan;Kim, Chan-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.1
    • /
    • pp.97-104
    • /
    • 2010
  • At present, the biological nutrient removal (BNR) process for removal of nitrogen and phosphorus is being constructing to keep pace with the reinforced standard of effluent quality and the traditional activated sludge process of preexistence is being promoting to retrofit. At the most case of retrofitting, processes are subjected to be under consideration as alternative BNR process for retrofitting. However, process evaluation methods are restricted to compare only treatment efficiency. Therefore, when BNR process apply, process evaluation was needed various method for treatment efficiency as well as sludge production and aeration cost, and all. In this study, the evaluation method of alternative process was suggested for the case for retrofitting S wastewater treatment plant which has been operated the standard activated sludge process. Three BNR processes for evaluation of proper alternatative process were selected and evaluated with suggested method. The selected $A^2$/O, VIP and DNR processes were evaluated using the mathematical model which is time and cost effective as well as gathered objective evaluation criteria. The evaluation between 5 individual criteria was possible including sludge production and energy efficiency as well as treatment performance. The objective final decision method for selection of optimal process was established through the fuzzy inference.

Removal Ratio of Nitrogen & Phosphorus according to Sewage Inflow in the Biological Treatment(Biological Nutrient Removal)Process (유입하수에 따른 BNR에서의 N과 P 제거율에 관한 연구)

  • Lee, Han-Seob;Choi, Sung-Bu;Chung, Kwang-Bo;Ahn, Sung-Hwan;Kim, Kyung-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.669-678
    • /
    • 2014
  • The amount of waste water generated from the domestic sources is consistently increasing in proportion to economic growth, and the conventional activated sludge process is widely being used for general waste water treatment. But the ministry of environment becomes stringthent treatment standards of N and P (less than 20mg/L of N, 2mg/L of P) to prevent the eutrophication of lake water, and therefore highly advanced treatment technology is required not only in the existing treatment plants where the activated sludge process is being used, but also in newly constructed treatment plants for the treatment of N and P. This study is aimed at highly operating the engineering technology method was developed by domestic to eliminate N and P at the same time. Experiments were conducted in the treatment plant located in Yong In city. The bioreactor was started from the principal equipment for the elimination of N and P and the elimination of organic compounds. It consists of an internal recycle piping from the end of the aerobic tank to the anoxic tank and external recycle piping from the final settling basin to the denitrification tank. By experiment of 4 types separate inflow of waste water to the denitrification tank and the anaerobic tank, and changes in staying time at the anoxic tank and the aerobic tank, the elimination of organic compounds in each type and the relationship in the efficiency between the elimination of N and P were researched.

Performance Estimation of SBR Aerobic Digestion Combined with Ultrasonication by Numerical Experiment (수치실험을 통한 초음파 결합형 SBR 호기성 소화의 거동 예측)

  • Kim, Sunghong;Kim, Donghan;Lee, Dongwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.6
    • /
    • pp.815-826
    • /
    • 2013
  • Using a developed mathematical model and calibrated kinetic constants, numerical experiments for a aerobic digestion of wastewater sludge by SBR aerobic digestion process combined with ultrasonication (USSBR) were performed in this study. It simulated well the phenomena of the decomposition of particulate organics and the release of organic nitrogen and transformation. To achieve 40 % of particulate organics removal, USSBR process requires only 6 days of SRT and 14 W/L of ultrasonic power whereas SBR aerobic digestion process requires 12 days of SRT. Based on the model simulation results, an empirical equation was presented here. This equation will be used to predict digestion efficiency for the given variables of SRT and ultrasonic power dose. USSBR aerobic digestion process can reduce the nitrogen concentration. The optimal operation strategy for the simultaneous removal of solids and soluble nitrogen in this process is estimated to 7 days of SRT with 14 W/L of ultrasonic power dose while anoxic period was 6 hours out of 24 hours of cycle time. In this condition, 40 % of particulate organics as well as 36 % of total nitrogen will be removed and the soluble nitrogen concentration of the centrate will be lower less then 40 mg/L.

Wastewater Treatment Plant Control Strategies

  • Ballhysa, Nobel;Kim, Soyeon;Byeon, Seongjoon
    • International journal of advanced smart convergence
    • /
    • v.9 no.4
    • /
    • pp.16-25
    • /
    • 2020
  • The operation of a wastewater treatment plant (WWTP) is a complex task which requires to consider several aspects: adapting to always changing influent composition and volume, ensuring treated effluents quality complies with local regulations, ensuring dissolved oxygen levels in biological reaction tanks are sufficient to avoid anoxic conditions etc. all of it while minimizing usage of chemicals and power consumption. The traditional way of managing WWTPs consists in having employees on the field measure various parameters and make decisions based on their judgment and experience which holds various concerns such as the low frequency of data, errors in measurement and difficulty to analyze historical data to propose optimal solutions. In the case of activated sludge WWTPs, parts of the treatment process can be automated and controlled in order to satisfy various control objectives. The models developed by the International Water Association (IWA) have been extensively used worldwide in order to design and assess the performance of various control strategies. In this work, we propose to review most recent WWTP automation initiatives around the world and identify most currently used control parameters and control architectures. We then suggest a framework to select WWTP model, control parameters and control scheme in order to develop and benchmark control strategies for WWTP automation.

A study on an intermittent aeration membrane bioreactor system using ammonia sensor to decrease energy consumption and sludge concentration by tubular membrane (암모니아 센서를 이용한 간헐폭기 Membrane bioreactor공정에서의 전력비 저감과 관형막을 이용한 슬러지 농축에 관한 연구)

  • Kang, Heeseok;Lee, Euijong;Kim, Hyungsoo;Jang, Am
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.161-170
    • /
    • 2014
  • It is essential to decrease energy consumption and excess sludge to economically operate sewage treatment plant. This becomes more important along with a ban on sea dumping and exhaustion of resource. Therefore, many researchers have been study on energy consumption reduction and strategies for minimization of excess sludge production from the activated sludge process. The aeration cost account for a high proportion of maintenance cost because sufficient air is necessary to keep nitrifying bacteria activity of which the oxygen affinity is inferior to that of heterotrophic bacteria. Also, additional costs are incurred to stabilize excess sludge and decrease the volume of sludge. There were anoxic, aerobic, membrane, deairation and concentration zone in this MBR process. Continuous aeration was provided to prevent membrane fouling in membrane zone and intermittent aeration was provided in aerobic zone through ammonia sensor. So, there was the minimum oxygen to remove $NH_4-N$ below limited quantity that could be eliminated in membrane zone. As the result of this control, energy consumption of aeration system declined by between 10.4 % and 19.1 %. Besides, we could maintain high MLSS concentration in concentration zone and this induced the microorganisms to be in starved condition. Consequentially, the amount of excess sludge decrease by about 15 %.

The Bacterial Community Structure in Biofilms of the RABC Process for Swine Butchery Wastewater Treatment (돼지 도축폐수 처리를 위한 RABC 공정의 생물막 세균군집 구조)

  • Sung, Gi-Moon;Lee, Dong-Geun;Park, Seong-Joo
    • Korean Journal of Microbiology
    • /
    • v.47 no.1
    • /
    • pp.56-65
    • /
    • 2011
  • Culture-independent microscopic observations and 16S rDNA analyses were applied to describe the bacterial community inherent to the biofilm structure of the RABC (Rotating Activated Bacillus Contactors) process for swine butchery wastewater treatment. The ratios of Gram-positive bacterial counts to total bacterial counts of the RABC process were significantly increased in the last aeration tank as well as returned sludge, while those of the existing A2O (Anaerobic-Anoxic-Oxic) process maintained constant from aeration tanks to returned sludge. Totally nine phyla were recovered by 16S rDNA analysis, two of which were major groups: the Proteobacteria (64.1%) and the Actinobacteria (18.4%). The third major group was the endospore-forming Firmicutes (5.4%). The remaining six minor groups are the Bacteroidetes (3.3%), the Chlorobi (2.2%), the Nitrospirae (1.1%), the Chlorofleix (1.1%), the Acidobacteria (1.1%), and the Fusobacteria (1.1%). The ratio of endospore-forming bacteria was 19.4%, which was composed of the members of the Firmicutes phylum (5.4%) and the Intrasporangiaceae family (14.0%) of the Actinobacteria phylum. Nitrifying and denitrifying related- and phosphorus accumulating related-sequences were composed of 6.5% and 5.4% of total community, respectively, these could mean the high capacity of the RABC process to remove odor compounds and reduce eutrophication by efficient removing inorganic nutrients.

Low Temperature Effects on the Nitrification in a Nitrogen Removal Fixed Biofilm Process Packed with SAC Media

  • Jang, Se-Yong;Byun, Im-Gyu
    • Journal of Environmental Science International
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • A fixed biofilm reactor system composed of anaerobic, anoxic(1), anoxic(2), aerobic(1) and aerobic(2) reactor was packed with synthetic activated ceramic (SAC) media and adopted to reduce the inhibition effect of low temperature on nitrification activities. The changes of nitrification activity at different wastewater temperature were investigated through the evaluation of temperature coefficient, volatile attached solid (VAS), specific nitrification rate and alkalinity consumption. Operating temperature was varied from 20 to $5^{\circ}C$. In this biofilm system, the specific nitrification rates of $15^{\circ}C$, $10^{\circ}C$ and $5^{\circ}C$ were 0.972, 0.859 and 0.613 when the specific nitrification rate of $20^{\circ}C$ was assumed to 1.00. Moreover the nitrification activity was also observed at $5^{\circ}C$ which is lower temperature than the critical temperature condition for the microorganism of activated sludge system. The specific amount of volatile attached solid (VAS) on media was maintained the range of 13.6-12.5 mg VAS/g media at $20{\sim}10^{\circ}C$. As the temperature was downed to $5^{\circ}C$, VAS was rapidly decreased to 10.9 mg VAS/g media and effluent suspended solids was increased from 3.2 mg/L to 12.0 mg/L due to the detachment of microorganism from SAC media. And alkalinity consumption was lower than theoretical value with 5.23 mg as $CaCO_3$/mg ${NH_4}^+$-N removal at $20^{\circ}C$. Temperature coefficient (${\Theta}$) of nitrification rate ($20^{\circ}C{\sim}5^{\circ}C$) was 1.033. Therefore, this fixed film nitrogen removal process showed superior stability for low temperature condition than conventional suspended growth process.