• Title/Summary/Keyword: Anodic limit

Search Result 54, Processing Time 0.028 seconds

Real-time Detection of Trace Copper in Brain and Kidney of Fish for Medical Diagnosis

  • Yang, Young Kyun;Pack, Eun Chul;Lee, Seung Ha;Yoo, Hai-Soo;Choi, Dal Woong;Ly, Suw Young
    • Toxicological Research
    • /
    • v.30 no.4
    • /
    • pp.311-316
    • /
    • 2014
  • For the detection of trace copper to be used in medical diagnosis, a sensitive handmade carbon nanotube paste electrode (PE) was developed using voltammetry. Analytical optimized conditions were found at 0.05 V anodic peak current. In the same conditions, various common electrodes were compared using stripping voltammetry, and the PE was found to be more sharply sensitive than other common electrodes. At optimum conditions, the working ranges of $3{\sim}19{\mu}gL^{-1}$ were obtained. The relative standard deviation of $70.0{\mu}gL^{-1}$ was determined to be 0.117% (n = 15), and the detection limit (S/N) was found to be $0.6{\mu}gL^{-1}$ ($9.4{\times}10^{-9}M$). The results were applied in detecting copper traces in the kidney and the brain cells of fish.

Electrochemical Behavior and Square Wave Voltammetric Determination of Doxorubicin Hydrochloride

  • Hahn, Young-Hee;Lee, Ho-Young
    • Archives of Pharmacal Research
    • /
    • v.27 no.1
    • /
    • pp.31-34
    • /
    • 2004
  • The electrochemical behavior of doxorubicin hydrochloride was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). From CV and SWV studies of doxorubicin hydrochloride in the acetate buffers of various pH values, it was found that protons were involved in the reduction of the antibiotic at the $H^+/e^$- ratio at one ( $\DeltaEp/pH =-53 ∼ -61 mV at 23^{\circ}C$), proposing the electrochemical reduction of the quinone moiety in its anthraquinone aglycone. Its electrochemical behavior was pseudo-reversible in the acetate buffer of pH 3.5 by exhibiting the well-defined single cathodic and anodic waves and the ratio of $lp^a/lp^c$ at approximately one over the scan rates of 10∼100 mV/s. Fast and sensitive SWV showing a single peak of doxorubicin has been applied for its quantitative analysis using an acetate buffer of pH 3.5. A linearity was obtained when the peak currents (lp) were plotted against concentrations of doxorubicin in the range of $5.0\times10^{-7} M∼1.0\times10^{-5}$M with a detection limit of $1.0\times10^{-7}$ M.

Anodic Stripping Voltammetric Determination of Iodide Ion with a Cinchonine-Copper(Ⅱ) Complex Modified Carbon Paste Electrode (Cinchonine-Copper(Ⅱ) 착물로 변성된 탄소반죽전극을 이용한 요오드 이온의 양극벗김전압전류법 정량)

  • Kwak, Myung Keun;Park, Deog Soo;Jeong, Euh Duck;Won, Mi Sook;Shim, Yoon Bo
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.5
    • /
    • pp.341-346
    • /
    • 1996
  • Electrochemical determination of iodide was carried out by stripping voltammetry with a $(Cin)Cu(NO_3)_2$ modified-carbon paste electrode. Iodide was coordinated onto the electrode surface containing $(Cin)Cu(NO_3)_2$ via ion exchange. The oxidation peak potential of incorporated iodide was +0.72 V. The optimum analytical conditions for the determination of iodide were investigated using linear sweep voltammetry. Optimum conditions for the electrochemical determination of iodide were as follows: i) A predeposition solution was 0.1 M $KNO_3.$ ii) The deposition time was 10 min. iii) The composition of the electrode was 40% (w/w). The detection limit for iodide was $1.0{\times}10^{-6}M$ and the relative standard deviation was ${\pm}5.5%\;in\;2.0{\times}10^{-5}M$(four repetitions). The interference effect of other anions were also investigated. $Cl^-,\;Br^-,\;C_2O_4^{2-},\;and\;ClO_4^-$ ions do not interfere for the determination of iodide. When $SCN^-$ was added to the deposition solution, the oxidation peak current of iodide ion was decreased roughly 32%.

  • PDF

Fabrication of Nano-filter Device for High Efficient Separation and Concentration of Biomolecules (고효율 바이오물질 분리 및 농축을 위한 나노필터소자제작)

  • Huh, Yun Suk;Choi, Bong Gill;Hong, Won Hi
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.738-742
    • /
    • 2012
  • Here, we develop a new nanofilter device for the rapid and efficient separation of nanoparticles and biomolecules, exploiting the use of AAO mebrane with ordered nanopores in the range from 20 nm to 200 nm. Briefly, the chip comprises of a series of the upper and lower PDMS channels containing embedded inlet and outlet ports, and $50{\mu}m$ width microfluidic channel, and AAO membrane to be made the filtering zone. After assembling these components, the acrylate plastic plates were used to fix the device on the top and bottom side. When introducing the samples into the inlet ports of the upper PDMS channel, we were able to separate and concentrate the nanoparticles and target molecules at the filtering zone, and to elute the solutions containing the unwanted materials toward the lower PDMS channels normal to the direction of AAO membrane. To demonstrate the usefulness of the device we apply it to the SERS detection of nucleic acid sequences associated with Dengue virus serotype 2. We report a limit of detection for Dengue sequences of 300 nM and show excellent enhancement of Raman signals from the filter zone of the nanofilter device.

Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode

  • Xu, Guang-Ri;Xu, Guifang;Xu, Ming-Lu;Zhang, Zhengqing;Tian, Yuan;Choi, Han-Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.415-419
    • /
    • 2012
  • Electrochemical characteristics of nitrite ion were investigated at a poly(methylene blue)-modified glassy carbon electrode by cyclic voltammetry and differential pulse voltammetry. The poly(methylene blue)-modified glassy carbon electrode exhibited enhanced anodic signals for nitrite. The effects of key parameters on the detection of nitrite were evaluated at the modified electrode, such as pH, accumulation time, and scan rate. Under optimum condition, the chemically modified electrode can detect nitrite in the concentration range $2.0{\times}10^{-6}$ to $5.0{\times}10^{-4}$ M with the detection limit of $2.0{\times}10^{-6}$ M and a correlation coefficient of 0.999. The detection of nitrite using the chemically modified electrode was not affected by common ions such as $Na^+$, $K^+$, $Ca^{2+}$, $Cl^-$, $HPO_4^{2-}$ and $H_2PO_4^- $. The modified electrode showed good stability and reproducibility. The practical application of the present method was successfully applied to the determination of nitrite ion in cabbage samples.

The Fabrication of Porous Nickel Oxide Thin Film using Anodization Process for an Electrochromic Device

  • Lee, Won-Chang;Choe, Eun-Chang;Hong, Byeong-Yu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.407.1-407.1
    • /
    • 2016
  • Electrochromism is defined as a phenomenon which involves persistently repeated change of optical properties between bleached state and colored state by simultaneous injection of electrons and ions, sufficient to induce an electrochemical redox process. Due to this feature, considerable progress has been made in the synthesis of electrochromic (EC) materials, improvements of EC properties in EC devices such as light shutter, smart window and variable reflectance mirrors etc. Among the variable EC materials, solid-state inorganics in particular, metal oxide semiconducting materials such as nickel oxide (NiO) have been investigated extensively. The NiO that is an anodic EC material is of special interest because of high color contrast ratio, large dynamic range and low material cost. The high performance EC devices should present the use of standard industrial production techniques to produce films with high coloration efficiency, rapid switching speed and robust reversibility. Generally, the color contrast and the optical switching speed increase drastically if high surface area is used. The structure of porous thin film provides a specific surface area and can facilitate a very short response time of the reaction between the surface and ions. The large variety of methods has been used to prepare the porous NiO thin films such as sol-gel process, chemical bath deposition and sputtering. Few studies have been reported on NiO thin films made by using sol-gel method. However, compared with dry process, wet processes that have the questions of the durability and the vestige of bleached state color limit the thin films practical use, especially when prepared by sol-gel method. In this study, we synthesis the porous NiO thin films on the fluorine doped tin oxide (FTO) glass by using sputtering and anodizing method. Also we compared electrical and optical properties of NiO thin films prepared by sol gel. The porous structure is promised to be helpful to the properties enhancement of the EC devices.

  • PDF

Sol-gel TiO2/Carbon Paste Electrode Nanocomposites for Electrochemical-assisted Sensing of Fipronil Pesticide

  • Maulidiyah, Maulidiyah;Azis, Thamrin;Lindayani, Lindayani;Wibowo, Dwiprayogo;Salim, La Ode Agus;Aladin, Andi;Nurdin, Muhammad
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.394-401
    • /
    • 2019
  • The unique study of TiO2 sol-gel modified carbon paste electrode (CPE) nanocomposites have been developed for electrochemical sensor detecting fipronil pesticide compound. We develop the easy synthesized TiO2 via a sol-gel method and modified in CPE which applied electrochemical system as cyclic voltammetry (CV) because the concentration is proportional with current peaks. We discover the TiO2 optimal mass used of 0.1 g which is compared with 0.7 g carbon and 0.3 mL paraffin. It has high-current anodic (Ipa) of 1.13×103 μA and high-current cathodic (Ipc) -0.96×103 μA in scan rate of 0.5 V/s. The limit of detection (LOD) of fipronil has been determined of 34.0×10-5 μM in percent recovery of 0.8%. Its high-stability for lifetime TiO2-CPE nanocomposites was expressed for 13 days which mean that can be used for detecting fipronil pesticide.

Nano SPR Biosensor for Detecting Lung Cancer-Specific Biomarker (폐암 바이오마커 검출용 나노SPR 바이오센서)

  • Jang, Eun-Yoon;Yeom, Se-Hyuk;Eum, Nyeon-Sik;Han, Jung-Hyun;Kim, Hyung-Kyung;Shin, Yong-Beom;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.144-149
    • /
    • 2013
  • In this research, we developed a biosensor to detect lung cancer-specific biomarker using Anodic Aluminum Oxide (AAO) chip based on interference and nano surface plasmon resonance (nanoSPR). The nano-porous AAO chip was fabricated $2{\mu}m$ of pore-depth by two-step anodizing method for surface uniformity. NanoSPR has sensitivity to the refractive index (RI) of the surrounding medium and also provides simple and label-free detection when specific antibodies are immobilized to the Au-deposited surface of nano-porous AAO chip. To detect the lung cancer-specific biomarker, antibodies were immobilized on the surface of the chip by Self Assembled Monolayer (SAM) method. Since then lung cancer-specific biomarker was applied atop the antibodies immobilized layer. The specific reaction of the antigen-antibody contributed to the change in the refractive index that cause shift of resonance spectrum in the interference pattern. The Limit of Detection (LOD) was 1 fg/ml by using our nano-porous AAO biosensor chip.

Electrochemical Behaviors of Hydroquinone on a Carbon Paste Electrode with Ionic Liquid as Binder

  • Sun, Wei;Jiang, Qiang;Yang, Maoxia;Jiao, Kui
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.915-920
    • /
    • 2008
  • In this paper the electrochemical behaviors of hydroquinone ($H_2Q$) were investigated on a carbon paste electrode using room temperature ionic liquid N-butylpyridinium hexafluorophosphate ($BPPF_6$) as binder (ILCPE) and further applied to $H_2Q$ determination. In pH 2.5 phosphate buffer solution (PBS), the electrochemical response of H2Q was greatly improved on the IL-CPE with a pair of well-defined quasi-reversible redox peaks appeared, which was attributed to the electrocatalytic activity of IL-CPE to the $H_2Q$. The redox peak potentials were located at 0.340 V (Epa) and 0.240 V (Epc) (vs. the saturated calomel electrode, SCE), respectively. The formal potential ($E^0$') was calculated as 0.290 V and the peak-to-peak separation (${\Delta}E_p$) was 0.100 V. The electrochemical parameters of $H_2Q$ on the IL-CPE were further calculated by cyclic voltammetry. Under the selected conditions the anodic peak current was linear with $H_2Q$ concentration over the range from $5.0\;{{\times}}\;10^{-6}$ to $5.0\;{\times}\;10^{-3}\;mol\;L^{-1}$ with the detection limit as $2.5\;{\times}\;10^{-6}\;mol\;L^{-1}$ (3$\sigma$ ) by cyclic voltammetry. The proposed method was successful applied to determination of $H_2Q$ content in a synthetic wastewater sample without the interferences of commonly coexisting substances.

Voltammetric measurements of iron using an infrared photodiode electrode (적외선 광 다이오드를 사용한 철의 전압전류 정량)

  • Ly, Suw Young;June, Young Sam;Lee, Hyun Ku;Kwak, Kyu Ju;Kim, Kun Woo;Kim, Jong Hyoung;Jeong, Ho Young;Kim, Bong Kyun;Chun, Seok Joo;Chang, Jin Won
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.289-295
    • /
    • 2007
  • A simple electric circuit of an infrared photodiode electrode (IPDE) was utilized to monitor iron using square-wave (SW) anodic stripping voltammetry (SV) and cyclic voltammetry (CV). The optimum analytical conditions were determined and were compared with those of common working electrodes. The comparison showed that CV is more sensitive and convenient to use than the common voltammetry methods. At the optimized conditions, the working ranges of 0.1- to 0.8- and 0.85- to 6.0 mg/L iron was obtained. Relative standard deviation of 15 measurements of iron (0.4 mg/L) was 0.09%. The analytical detection limit was found to be $80{\pm}0.6ug/L$, which was applied to iron in waste water.