• Title/Summary/Keyword: Anodic Oxidation

Search Result 324, Processing Time 0.02 seconds

Bioactivity of precalcified nanotubular $TiO_2$ layer on Ti-6Al-7Nb alloy (나노튜브 $TiO_2$ 층 생성 후 전석회화 처리한 Ti-6Al-7Nb 합금의 생체활성도)

  • Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.16-21
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the bioactivity of precalcified nanotubular $TiO_2$ layer on Ti-6Al-7Nb alloy. Materials and methods: Anodic oxidation was carried out at a potential of 20 V and current density of 20 mA/$cm^2$ for 1 hour. The glycerol solution containing 1 wt% $NH_4F$ and 20 wt% deionized water was used as an electrolyte. Precalcification treatment was obtained by soaking in $Na_2HPO_4$ solution at $80^{\circ}C$ for 30 minutes followed by soaking in saturated $Ca(OH)_2$ solution at $100^{\circ}C$ for 30 minutes, followed by heat treatment at $500^{\circ}C$ for 2 hours. To evaluate the activity of precalcified nanotubular $TiO_2$ layer, specimens were immersed in a simulated body fluid with pH 7.4 at $36.5^{\circ}C$ for 10 days. Results: 1. Nanotubular $TiO_2$ layer showed the highly ordered dense structure by interposing small diameter nanotubes between large ones, the shape of nanotubes was enlarged as going down. 2. The mean length of nanotubes was $517.0{\pm}23.2\;nm$ innm glycerol solution containing 1 wt% $NH_4F$ and 20 wt% $H_2O$ at 20 V for 1 hour. 3. The bioactivity of Ti-6Al-7Nb alloy was improved with formation of nanotubular $TiO_2$ layer and precalcification treatment in $80^{\circ}C$ 0.5 M $Na_2HPO_4$ and saturated $100^{\circ}C$ $Ca(OH)_2$ solution. Conclusion: Bioactivity of precalcified nanotubular $TiO_2$ layer on Ti-6Al-7Nb alloy was improved.

Electrochemical Evaluation of Cadmium and Lead by Thiolated Carbon Nanotube Electrodes (티올화된 탄소나노튜브 전극을 이용한 카드뮴과 납의 전기화학적 분석)

  • Yang, Jongwon;Kim, Lae-Hyun;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.24 no.5
    • /
    • pp.551-557
    • /
    • 2013
  • In the present study, pristine carbon nanotube (p-CNT) and thiolated carbon naotube (t-CNT) electrodes were investigated to improve their detectabilities for cadmium (Cd) and lead (Pb). In addition, we evaluate which reaction mechanism is used when the electrolyte contains both Cd and Pb metals. Square wave stripping was employed for analyzing the sensitivity for the metals. A frequency of 30 Hz, a deposition potential of -1.2 V vs. Ag/AgCl and a deposition time of 300 s were used as optimal SWSV parameters. t-CNT electrodes show the better sensitivity for both Cd and Pb metals than that of p-CNT electrodes. In case of Cd, sensitivities of p-CNT and t-CNT electrodes were $3.1{\mu}A/{\mu}M$ and $4.6{\mu}A/{\mu}M$, respectively, while the sensitivities for Pb were $6.5{\mu}A/{\mu}M$ (p-CNT) and $9.9{\mu}A/{\mu}M$ (t-CNT), respectively. The better sensitivity of p-CNT electrodes is due to the enhancement in the reaction rate of metal ions that are facilitated by thiol groups attached on the surface of CNT. When sensitivity was measured for the detection of Cd and Pb metals present simultaneously in the electrolyte, Pb indicates better sensitivity than Cd irrespective of electrode types. It is ascribed to the low standard electrode potential of Pb, which then promotes the possibility of oxidation reaction of the Pb metal ions. In turn, the Pb metal ions are deposited on the electrode surface faster than that of Cd metal ions and cover the electrode surface during deposition step, and thus Pb metals that cover the large portion of the surface are more easily stripped than that of Cd metals during stripping step.

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.

Effects of conditions for anodization and cyclic precalcification treatments on surface characteristics and bioactivity (양극산화와 석회화 순환처리 조건이 타이타늄 박판의 표면특성 및 생체활성에 미치는 영향)

  • Jang, Yong-Seok;Lee, Kang-Gyu;Jeon, Woo-Yong;Han, A-Lum;Lim, Chung-Ha;Lee, Min-Ho;Bae, Tae-Sung
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.243-256
    • /
    • 2018
  • The purpose of this study was to investigate the effects of the anodization and cyclic calcification treatment on the surface characteristic and bioactivity of the titanium thin sheet in order to obtain basic data for the production of bioactive titanium membrane. A $30{\times}20{\times}0.08mm$ titanium sheets were prepared, and then they were pickled for 10 seconds in the solution which was mixed with $HNO_3:HF:H_2O$ in a ratio of 12: 7: 81. The $TiO_2$ nanotube layer was formed to increase the specific surface area of the titanium, and then the cyclic calcification treatment was performed to induce precipitation of hydroxiapatite by improvement of the bioactivity. The corrosion resistance test, wettability test and immersion test in simulated body solution were conducted to investigate the effect of these surface treatments. The nanotubes formed by the anodization treatment have a dense structure in which small diameter tubes are formed between relatively large diameter tubes, and their inside was hollow and the outer walls were coupled to each other. The hydroxyapatite precipitates were well combined on the nanotubes by the penetration into the nanotube layer by successive cyclic calcification treatment, and the precipitation of hydroxyapatite tended to increase proportionally after immersion in simulated body solution as the number of cycles increased. In conclusion, it was confirmed that induction of precipitation of hydroxyapatite by cyclic calcification treatment after forming the nanotube $TiO_2$ nanotube layer on the surface of the titanium membrane can contribute to improvement of bioactivity.