• Title/Summary/Keyword: Annual Exposure Dose

Search Result 122, Processing Time 0.022 seconds

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

A Sensitivity Study on Nuclide Release from the Near-field of the Pyroprocessed Waste Repository System: Part 1. A Probabilistic Approach (파이로처리 폐기물 처분 시스템 근계 영역 내 핵종 유출 민감도: 제 1 부 확률론적 접근)

  • Lee, Youn-Myoung;Jeong, Jongtae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.19-35
    • /
    • 2014
  • A parametric sensitivity to the annual exposure dose rate to the farming exposure group has been probabilistically carried out for three principal elements associated with the nuclide transport behavior in the near-field of the pyroprocessed waste repository system. Credit time for both metal and ceramic containers, annual nuclide release rete, and the degree of loss of bentonite buffer around the container are selected as the elements and investigated for important nuclides. All the elements are shown to be sensitive to the results. Methodology studied through this study and the results are expected to make a good feedback to the repository design. As a follow-up study, separated in Part 2, the A-KRS will be deterministically assessed and then compared among each other with the normal, the worst, and the best case scenarios associated with their extreme values these elements could have.

Factors Related to the Self Perceived Health Status of Farmers (농업인의 주관적 건강상태 관련 요인)

  • Beomseok Ko;Sangchul Roh;Jeongbae Rhie;Min-Gi Kim;Young-Sun Min
    • Journal of agricultural medicine and community health
    • /
    • v.48 no.3
    • /
    • pp.178-188
    • /
    • 2023
  • Objective: Self perceived health status dose not only reflects an individual's perception of their overall well-being but is also known to be influenced by various aspects of life. Rural areas tend to have relatively lower quality of life compared to urban areas. Therefore, this study aims to investigate factors related to Self perceived health status among farmers. Methods: In the subjective health status questionnaire, responses of "very healthy" and "healthy" are classified as 'good', whereas "average", "unhealthy" or "very unhealthy" are classified as indicative of a 'poor' subjective health status. Logistic regression analysis was conducted to calculate odds ratios(OR), aiming to investigate factors related to self perceived health status. Results: The OR for self perceived health status as poor was statistically significant for females at 2.32(95% CI 1.47-3.67), for individuals working in greenhouses at 1.43(95% CI 1.01-1.98), for current smoker at 1.50(95% CI 1.02-2.08), and for those who experienced symptoms after pesticide exposure at 1.74(95% CI 1.13-2.67). An annual income of 50 million won or more had a statistically significant OR of 0.51(95% CI 0.28-0.91), education level of high school and above had an OR of 0.45(95% CI 0.32-0.63), and engaging in physical exercise had an OR of 0.61(95% CI 0.42-0.89). Conclusions: The factors related to self perceived health status were identified as sex, smoking, cultivation type, presence of symptoms after pesticide exposure, annual income, education level, and exercise status. The significance of this study lies in providing foundational data for the development of health management programs for farmers.

Convergence analysis of safety management for radiation workers and diagnostic radiation-generator devices of animal hospital in Korea (국내 동물병원의 진단용 방사선 발생장치 및 방사선 관계종사자 안전관리에 관한 융복합적 분석)

  • Kang, Kyoung-Mook;Suh, Tae-Young;Kim, Yong-Sang;Yun, Seon-Jong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.55-61
    • /
    • 2020
  • The various types of radiation-generator devices have been used in animal hospitals, and the safety for radiation workers is becoming important in Korea. This study investigated and analyzed the radiation safety management for diagnostic radiation-generator devices and radiation workers of animal hospital. The number of radiation-generator devices and radiation workers of animal hospital increased from 2,138 to 2,972 and from 2,644 and 5,733 for six years. The number of general X-ray, CT, C-arm, portable and dental X-ray in 2019 were 2,204, 58, 67, 770, and 14. The number of veterinarian, veterinary nurse, veterinary assistant, and others in 2019 were 4,236, 1,080, 404, and 13. The average exposure dose of radiation workers in 2018 were 0.21mSv in surface dose, 0.18mSv in depth doses. This study is expected to be the basic data for the safety management of radiation-generating devices and radiation workers in animal hospital.

Radiological Risk Assessment for the Public Under the Loss of Medium and Large Sources Using Bayesian Methodology (베이지안 기법에 의거한 중대형 방사선원의 분실 시 일반인에 대한 방사선 위험도의 평가)

  • Kim, Joo-Yeon;Jang, Han-Ki;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.91-97
    • /
    • 2005
  • Bayesian methodology is appropriated for use in PRA because subjective knowledges as well as objective data are applied to assessment. In this study, radiological risk based on Bayesian methodology is assessed for the loss of source in field radiography. The exposure scenario for the lost source presented in U.S. NRC is reconstructed by considering the domestic situation and Bayes theorem is applied to updating of failure probabilities of safety functions. In case of updating of failure probabilities, it shows that 5 % Bayes credible intervals using Jeffreys prior distribution are lower than ones using vague prior distribution. It is noted that Jeffreys prior distribution is appropriated in risk assessment for systems having very low failure probabilities. And, it shows that the mean of the expected annual dose for the public based on Bayesian methodology is higher than the dose based on classical methodology because the means of the updated probabilities are higher than classical probabilities. The database for radiological risk assessment are sparse in domestic. It summarizes that Bayesian methodology can be applied as an useful alternative lot risk assessment and the study on risk assessment will be contributed to risk-informed regulation in the field of radiation safety.

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.

Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure (의료기관 지하시설의 라돈가스 측정과 내부피폭 조사)

  • Song, Jea-Ho;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.231-235
    • /
    • 2011
  • Radium is rock or soil of crust or uranium of building materials and thorium after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like mine or basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. Radium sheath of medical institution treat person's life is possible big danger to professional regarding radioactivity who has much amount exposed radioactivity and weaker immune patient. so we do this test. Using measuring instrument at test is real time radium measuring instrument, Professional Continuous Radon monitor, and measuring places are basement first floor and second floor of two hospitals and measure from 10 a.m to 3 p.m. Measurement result of Professional Continuous Radon monitor is minimum 14.8 Bq/$m^3$ to maximum 70.3 Bq/$m^3$ and show domestic baseline below 148 Bq/$m^3$, effective dose-rate is minimum 0.296 mSv to maximum 1.406 mSv that show 2.4 mSv, 10~58.3% level, exposed radiation amount from nature radiation one year.

Methodology on the Safety Goal Setting of Reactor Operation based on the Radiogenic Excess Cancer Risk in Korea (한국인의 초과 방사선 암 위험도 평가에 근거한 국내원전의 안전목표치 설정 방법론)

  • Chang, Si-Young;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.131-142
    • /
    • 1999
  • By using the Korean demographic data and the modified relative risk projection model given in the Committee on the Biological Effect of Ionizing Radiation (BEIR) report-V under the U.S. National Academy of Science, the radiogenic excess risk in Korean population has been evaluated. On the basis of this risk, a safety goal for the safe operation of domestic nuclear power plants has been further derived in terms of personal dose. The baseline risk of death due to all causes in Korea and the trivial risk level, which the society considers safe, were estimated to be $5.2{\times}10^{-3}$ and $5.2{\times}10^{-6}$, respectively. The radiogenic excess cancer risk in Korea has been estimated to be $5.2{\times}10^{-3}$ for tie case of acute exposure to 0.1 Gy and $3.7{\times}10^{-3}$ for the case of chronic lifetime exposure to 1.0 mGy/y. On the basis of these risks estimate, the resulting safety goal for one year opeation of a reactor was 0.05 mSv, which is quite identical with the ALARA guideline prescribed by the USNRC in the Appendix I, 10CFR50.

  • PDF

Radiological Risk Assessment for $^{99m}Tc$ Generator using Uncertainty Analysis (불확실성 분석을 이용한 $^{99m}Tc$ 발생기 사용의 방사선위험도 평가)

  • Jang, H.K.;Kim, J.Y.;Lee, J.K.
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.129-139
    • /
    • 2004
  • Recently, much attentions are paid to the risk associated with increased uses of medium size radiation sources in medical and industrial fields. In this study, radiation risks to the worker and to the general public due to $^{99m}Tc$ generator were assessed for both normal and accident conditions. Based on the event tree technique, exposure scenarios for various situations were derived. Uncertainty analysis based on the Monte-Carlo technique was applied to the risk assessment for workers and members of the public in the vicinity of the work place. In addition, sensitivity analysis was performed on each of the five independent input parameters to identify importance of the parameters with respect to the resulting risk. Because the frequencies of normal tasks are fat higher than those of accidents, the total risk associated with normal tasks were higher than the accident risk. The annual dose due to normal tasks were $0.6mSv\;y^{-1}$ for workers and $0.014mSv\;y^{-1}$ for public, while in accident conditions $3.96mSv\;y^{-1}\;and\;0.0016mSv\;y^{-1}$, respectively. Uncertainty range of accident risk was higher by 10 times than that of normal risk. Sensitivity analysis revealed that source strength, working distance and working time were crucial factors affecting risk. This risk analysis methodology and its results will contribute to establishment of risk-informed regulation for medium and large radioactive sources.

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF