• Title/Summary/Keyword: Anion detection

Search Result 78, Processing Time 0.024 seconds

Selective acetate detection using functional carbon nanotube fiber

  • Choi Seung-Ho;Lee, Joon-Seok;Choi, Won-Jun;Lee, Sungju;Jeong, Hyeon Su;Choi, Seon-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.357-363
    • /
    • 2021
  • We developed a chemiresistive anion sensor using highly conductive carbon nanotube fibers (CNTFs) functionalized with anion receptors. Mechanically robust CNTFs were prepared via wet-spinning utilizing the nematic liquid crystal properties of CNTs in chlorosulfonic acid (CSA). For anion detection, polymeric receptors composed of dual-hydrogen bond donors, including thiourea 1, squaramide 2, and croconamide 3, were prepared and bonded non-covalently on the surface of the CNTFs. The binding affinities of the anion receptors were studied using UV-vis titrations. The results revealed that squaramide 2 exhibited the highest binding affinity toward AcO-, followed by thiourea 1 and croconamide 3. This trend was consistent with the chemiresistive sensing responses toward AcO- using functional CNTFs. Selective anion sensing properties were observed that CNTFs functionalized with squaramide 2 exhibited a response of 1.08% toward 33.33 mM AcO-, while negligible responses (<0.1%) were observed for other anions such as Cl-, Br-, and NO3-. The improved response was attributed to the internal charge transfer of dual-hydrogen bond donors owing to the deprotonation of the receptor upon the addition of AcO-.

A Naked Eye Detection of Fluoride with Urea Receptors Which have both an Azo Group and a Nitrophenyl Group as a Signaling Group

  • Dang, Nhat Tuan;Park, Jin-Joo;Jang, Soon-Min;Kang, Jong-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1204-1208
    • /
    • 2010
  • Anion recognition via hydrogen-bonding interactions could be monitored with changes in UV-vis absorption spectra and in some cases easily monitored with naked eye. Urea receptors 1 and 2 connected with both an azo group and a nitrophenyl group as a signaling group for color change proved to be an efficient naked eye receptor for the fluoride ion. The anion recognition phenomena of the receptors 1 and 2 via hydrogen-bonding interactions were investigated through UV-vis absorption and $^1H$ NMR spectra.

Determination of Glyphosate in Whole Blood by HPLC-fluorescence Detection (HPLC 형광검출법에 의한 Glyphosate의 혈중농도 측정)

  • 이상기;김기욱;양자열;인상환;이수연
    • YAKHAK HOEJI
    • /
    • v.45 no.4
    • /
    • pp.347-351
    • /
    • 2001
  • A rapid and sensitive method for the determination of glyphosate, a phosphated amino acid herbicide, in whole blood is presented. After removal of protein, the whale blood was purified by using the anion exchange resin (Dowex 1), and derivatized with 9-fluorenylmethyl chloroformate (FMCL). Derivatized glyphosate from blood sample was injected onto a Whatman partisil 10SAX column and separated with 0.1M phosphate buffer (pH 2.5) and acetonitrile (ratio=3:1). The high performance liquid chromatography-fluorescence detection gave the detection limit of 86pg and linearity of 0.9999 in the range of 0.25 $\mu$g/ml and 25 $\mu$g/ml. The recoveries of glyphosate added to the blood samples were ranged from 75.3% to 100.4% compared to the samples prepared in water. The derivatized glyphosate was stable at various acidity and temperature. This method has been successfully applied to the blood samples of lethal intoxication with the herbicide glyphosate.

  • PDF

Analysis of Anions by Indirect Photometric Detection (I) (간접 분광 검출법에 의한 음이온의 분석(I))

  • Park, Man-Ki;Kim, Bak-Kwang;Park, Jeong-Hill;Kim, Kyoung-Ho;Lee, Mi-Yung;Jung, Jae-Eun
    • YAKHAK HOEJI
    • /
    • v.34 no.3
    • /
    • pp.215-218
    • /
    • 1990
  • An ion chromatographic method based on indirect photometric detection of UV transparent anions was developed. Separation of anion was accomplished on strong anion exchange column (Waters SAX) using UV detector at 254 nm. Among examined UV-active additives (Dns-H, Dns-glu, Dnsser, Dns-val), Dns-glu showed the highest sensitivity. Studies on the effects of the pH and ionic strength of eluent revealed that the increase of pH and ionic strength of the eluent decreased capacity factor. The best eluent for the separation of acetate, fluoride, chloride, nitrate and bromide was $1\;{\times}\;10^{-4}M$ Dns-glu in 5 mM phosphate buffer (pH 6.30). The detection limit of chloride ion was 2.1 ng in this condition.

  • PDF

Ion Exchange Recovery of Rhenium and Its Determination in Aqueous Solutions by Diffuse Reflection Spectroscopy

  • Kalyakina, O.P.;Kononova, O.N.;Kachin, S.V.;Kholmogorov, A.G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.1
    • /
    • pp.79-84
    • /
    • 2004
  • The existing technological schemes for processing rhenium-containing raw materials involve the recovery of Re from solutions, which can be effectively achieved by anion exchange method. The application of anion exchange also allows to study rhenium state in aqueous solutions and to develop analytical control methods. The present work is focused on investigation of ion exchange equilibrium in the analytical system Re(VII)-HCl-$SnCl_2$-KSCN-anion exchanger by means of sorption-desorption method as well as by electron, IR- and diffuse reflection spectroscopy. It was shown that rhenium can be quantitatively recovered from this system. It is proposed to use the sorption-spectroscopic method for Re(VII) determination in aqueous solutions. The calibration curve is linear in the concentration range of 0.5-20.0 mg/L (sample volume is 25.0 mL) and the detection limit is 0.05 mg/L. The presence of Mo(VI), Cu(II), Fe(II, III), Ni(II), Zn(II) as well as $K^+,\;Na^+$ do not hinder the solid-phase determination of rhenium. Rhenium (VII) determination by diffuse reflection spectroscopy was carried out in model solutions as well as in samples of river-derived water and in solutions obtained after the dissolution of spent catalysts.

Ion-Based Micro Vibration Sensor for Ultra-High Frequency Vibration Detection (초고주파수 진동 감지를 위한 이온 질량기반 진동센서)

  • Kim, Kwang-Ho;Seo, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.728-732
    • /
    • 2008
  • This paper presents ion-based micro vibration sensor for the ultra-high frequency vibration detection. Presented sensor uses the motion of anion and cation in an electrolyte. Electrolyte vibration sensors have the high shock survival characteristics and a simple read-out circuit because of the small mass and own charges of ions. Presented sensor measures the induced electric potential by the mechanical-electrical coupling. It consist of electrolyte chamber and detection electrode. Electrolyte chamber was fabricated by PDMS molding. Detection electrode was made of gold evaporation on pyrex glass. Size of electrolyte chamber was designed as $600{\times}600{\times}100um$. Detection electrode had 200nm-thick and 42um-gap. In the experimental study, 5.8M sodium Chloride (NaCl) solution was used as electrolyte in 36nl-chamber. Mechanical vibration was measured from 2kHz to 4MHz.

Ion Chromatography of Anions with Indirect UV-Photometric Detection by using Naphthalene Trisulfonic Acid and Naphthalene Disulfonic Acid as an Eluent (Naphthalene Trisulfonic Acid 및 Naphthalene Disulfonic Acid을 이용한 음이온 간접자외선흡광검출 이온크로마토그래피)

  • Lee, Kwang-Pill;Cheon, Hwi-Kyung;Seo, Hyun-Kyung;Kwon, Se-Mog;Park, Keung-Shik;Tanaka, Kazuhiko;Ohta, Kazutoku
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.111-115
    • /
    • 1999
  • Single column anion chromatography by indirect UV detection was applied to the determination of 7 common anions($H_2PO_4^-$, $Cl^-$, $NO_2^-$, $NO_3^-$, $I^-$, $SO_4^{2-}$, $SCN^-$). A low capacity silica-based anion-exchange column(TSK guardgel QAE-SW; ca. 0.3 meq./g; 4.6 mm i.d${\times}$150 mm) was used. In separating common anions, we compared naphthalene trisulfonic acid(NTS) and naphthalene disulfonic acid(NDS) to find more sensitive, selective and rapid separation method. And cations and anions can be separated simultaneously in 0.20 mM NTS-5% acetonitrile-water.

  • PDF