• 제목/요약/키워드: Animal Imaging

검색결과 408건 처리시간 0.024초

Nondestructive sensing technologies for food safety

  • Kim, M.S.;Chao, K.;Chan, D.E.;Jun, W.;Lee, K.;Kang, S.;Yang, C.C.;Lefcourt, A.M.
    • 한국환경농학회:학술대회논문집
    • /
    • 한국환경농학회 2009년도 정기총회 및 국제심포지엄
    • /
    • pp.119-126
    • /
    • 2009
  • In recent years, research at the Environmental Microbial and Food Safety Laboratory (EMFSL), Agricultural Research Service (ARS) has focused on the development of novel image-based sensing technologies to address agro-food safety concerns, and transformation of these novel technologies into practical instrumentation for industrial implementations. The line-scan-based hyperspectral imaging techniques have often served as a research tool to develop rapid multispectral methods based on only a few spectral bands for rapid online applications. We developed a newer line-scan hyperspectral imaging platform for high-speed inspection on high-throughput processing lines, capable of simultaneous multiple inspection algorithms for different agro-food safety problems such as poultry carcass inspection for wholesomeness and apple inspection for fecal contamination and defect detection. In addition, portable imaging devices were developed for in situ identification of contamination sites and for use by agrofood producer and processor operations for cleaning and sanitation inspection of food processing surfaces. The aim of this presentation is to illustrate recent advances in the above agro.food safety sensing technologies.

  • PDF

Far lateral lumbar disc extrusion in a dachshund dog

  • Kim, Jaehwan;Kim, Hyoju;Hwang, Jeongyeon;Eom, Kidong
    • 대한수의학회지
    • /
    • 제59권3호
    • /
    • pp.165-169
    • /
    • 2019
  • A 6-year-old Dachshund was presented with acute, non-localized pain without neurological dysfunction. Radiography revealed multiple calcifications of intervertebral discs and narrowing of disc space in the thoracolumbar region. Computed tomography and magnetic resonance imaging revealed calcified disc-like material entrapped in the left extraforaminal area and showed a displaced nerve root. Fenestration and removal of the extruded disc material were performed in a routine manner. Histopathological examination showed degenerative disc materials with severe calcification both in the nucleus pulposus and around the annulus fibrosis. Based on imaging, surgical, and histopathologic results, the dog was diagnosed with far lateral lumbar disc extrusion.

Ectopic insulinoma in a dog with insulin-induced hypoglycemia: a case report

  • Jiwon Kim;Insun Hwang;Danbee Kwon;Kanghyo Park;Hakyoung Yoon
    • Journal of Veterinary Science
    • /
    • 제24권3호
    • /
    • pp.39.1-39.6
    • /
    • 2023
  • A 7-year-old spayed female Shih Tzu dog was presented for evaluation of recurrent hypoglycemia. Serum insulin levels during hypoglycemia were 35.3 µIU/mL. Ultrasonography and computed tomography showed a mesenteric nodule between the kidney and the portal vein, but no pancreatic mass was observed. During surgery, the nodule had neither anatomical adhesions nor vascular connections to the pancreas. Pancreatic inspection and palpation revealed no abnormalities. Hypoglycemia improved after resection of the nodule. Histopathological examination confirmed the nodule to be an islet cell carcinoma. Although extremely rare, ectopic insulinoma should be considered as a possible cause of insulininduced hypoglycemia in dogs.

A Simple Confocal Microscopy-based Method for Assessing Sperm Movement

  • Kim, Sung Woo;Kim, Min Su;Kim, Chan-Lan;Hwang, In-Sul;Jeon, Ik Soo
    • 한국발생생물학회지:발생과생식
    • /
    • 제21권3호
    • /
    • pp.229-235
    • /
    • 2017
  • In the field of reproductive medicine, assessment of sperm motility is a key factor for achieving successful artificial insemination, in vitro fertilization, or intracellular sperm injection. In this study, the motility of boar sperms was estimated using real-time imaging via confocal microscopy. To confirm this confocal imaging method, flagellar beats and whiplash-like movement angles were compared between fresh and low-temperature-preserved ($17^{\circ}C$ for 24 h) porcine sperms. Low-temperature preservation reduced the number of flagellar beats from $11.0{\pm}2.3beats/s$ (fresh sperm) to $5.7{\pm}1.8beats/s$ and increased the flagellar bending angle from $19.8^{\circ}{\pm}13.8^{\circ}$ (fresh) to $30.6^{\circ}{\pm}15.6^{\circ}$. These data suggest that sperm activity can be assessed using confocal microscopy. The observed motility patterns could be used to develop a sperm evaluation index and automated confocal microscopic sperm motility analysis techniques.

소 동물 촬영을 위한 Micro-CT의 개발 (Development of a Micro-CT System for Small Animal Imaging)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 2004
  • 소 동물 촬영에 이용될 수 있는 고해상도의 x-선 cone-beam micro computed tomography (micro-CT) 시스템을 개발하였다 Micro-CT 시스템은 120${\times}$120 mm2 의 2차원 평판 x-선 감지기, micro-focus x-선 발생장치, 주사 기구부, 병렬처리 영상 재구성 시스템으로 이루어져 있다. 개발된 시스템의 성능을 평가하기 위해 대조도와 공간해상도를 측정하였다. 대조도 실험에서는 95 mGy 에서 36 CT-번호를 구별할 수 있음을 확인하였고, 공간 해상도 실험에서는 14 lp/mm 의 성능을 확인하였다. 소 동물 촬영 결과로 실험용 쥐의 대퇴부, 심장 그리고 복부 동맥 혈관을 촬영한 경상을 제시하였다. 개발된 micro-CT 시스템은 소 동물을 이용한 생명공학 분야 연구에 널리 이용될 수 있을 것으로 기대된다.

Image quality assessments of focal spot size on radiographic images in dogs

  • Park, Sujin;Hwang, Tae Sung;Lee, Hee Chun
    • 대한수의학회지
    • /
    • 제62권1호
    • /
    • pp.8.1-8.6
    • /
    • 2022
  • The aim of this prospective study was to investigate the effects of focal spot size of X-ray tube on sharpness of clinical radiographic images of dogs and cats. Radiographic images of 24 stifle joints, 15 carpi, 18 lumbar spines, 61 thoraxes, and 47 abdomens of 102 dogs and 4 cats were obtained in the present study, using 2 X-ray tubes with nominal focal spots of 2.0 mm and 0.6 mm, respectively. The sharpness of specific anatomical structures in all the images of 5 projections was assessed. The radiographic sharpness of various anatomical structures of lumbar spine and cortex of stifle with fine focal spot was increased significantly compared with broad focal spot images. In addition, the blurred motion was significantly higher in the fine focal spot images of thorax. In conclusion, our study suggests that a selective use of fine foci for imaging of lumbar spine or cortex of stifle enhanced radiographic sharpness.

분자영상의 윤리 및 규제 (Ethical and Regulatory Problems of Molecular Imaging)

  • 정재민
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.140-142
    • /
    • 2004
  • As a molecular imaging is the most up-to-date technology in Nuclear Medicine, it has complicate ethical and regulatory problems. For animal experiment, we have to follow institutional animal care committee. for clinical experiment, we have to get approval of Institutional Review Board according to Helsinki declaration. In addition, approval from Korea Food and Drug Administration (KFDA) is essential for manufacturing and commercialization. However, too much regulation would suppress development of new technology, which would result in the loss of national competitive power. In addition, most new radioactive ligands for molecular imaging are administered to human at sub-pharmacological and sub-toxicological level. In conclusion, a balanced regulation is essential for the safety of clinical application and development of new technology.

고주파 초음파의 그 응용: 혈관과 혈액을 중심으로한 동물과 인체 영상 (High Frequency Ultrasound and Its Applications to Animal and Human Imaging Focusing on Vessel and Blood)

  • 복태훈;팽동국
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.73-85
    • /
    • 2010
  • In the diagnostic ultrasound (US) transducer technology, the high frequency US(HFUS) transducer over 20 MHz is one of the current issues to be pursued for better resolution with the expense of penetration. HFUS single element transducers and the mechanical scanning systems for imaging are reviewed, and HFUS array transducers are also briefly summarized. HFUS applications such as the human applications in ophthalmology and dermatology and small animal applications for research purposes are reviewed with vascular and blood imaging in this paper.