• 제목/요약/키워드: Angular deviation

검색결과 95건 처리시간 0.028초

안모비대칭의 진단용 기준선의 유용성에 관한 연구 (A STUDY ON USEFULNESS OF THE REFERENCE LINE IN DIAGNOSIS OF THE FACIAL ASYMMETRY)

  • 류성호;장현호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제31권3호
    • /
    • pp.266-273
    • /
    • 2005
  • Purpose: To assess the relationship between soft tissue reference line and hard tissue reference line using the standardized photographs and the posteroanterior cephalometric radiographs(P-A)in facial asymmetric patients and to compare the differences of angular measurement between normal group and asymmetry group. Methods: Normal group consisted of 44 persons with normal occlusion and normal facial morphology. Asymmetry group consisted of 90 patients with facial asymmetry. Standardized facial photographs and P-A were taken in all subjects. The horizontal reference lines were bipupillary line in photographs and latero-orbitale line in P-A respectively. The vertical reference line were the line from the midpoint of horizontal reference line perpendicularly. Angular measurement of otobasion canting, lip canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in photographs. And angular measurement of mastoid canting, mandibular canting, nose deviation, chin deviation, and maxillary deviation were compared and analyzed in P-A. Results: 1. The variables of photographs and P-A were significantly related in the asymmetry group. 2. Significant differences between all variables except for PT2 and PA2 were shown in the asymmetry group and between PT1 and PA1, PT3 and PA3 in the normal group respectively. 3. Comparison measurement scores of angular difference between control group and experimental group concerning each variable showed significant difference except for PA1. Conclusions: Soft tissue components may not compensate for underlying skeletal imbalance in nose deviation and chin deviation. The horizontal reference lines in photographs were significant related with the P-A, but angular variables between the two studies show significant differences. Therefore, we do not recommend use photography in the assessment the facial asymmetry as complemented in the P-A.

항공기 투명체의 편각개념 설계 및 측정 시스템 개발 (Concept Design of Angular Deviation and Development of Measurement System for Transparency in Aircraft)

  • 문태상;우성조;권성일;류광열
    • 한국항공우주학회지
    • /
    • 제38권11호
    • /
    • pp.1123-1129
    • /
    • 2010
  • TA-50 항공기에 적용되는 투명체의 편각은 실제목표와 투명체를 통해 조종사가 인식하는 목표와 차이를 유발시켜, 부정확한 조준 및 이로 인한 무장계통의 정확도를 저하시킨다. 이러한 문제를 해결하기 위해 TA-50 항공기에서는 원드실드 투명체의 편각을 실측하여 편각 계수 형태로 항공기의 통합임무시현컴퓨터에 입력, 각도 편차를 보정하여 전방상향 시현기에서 목표물에 정확히 조준되도록 한다. 이러한 작동원리를 실전에 적용하기 위해 본 연구에서는 편각 자동측정장비를 국내 최초 독자적으로 개발하였다. 또한 편각 유도공식 산출 등 개발개념 및 운영 체계와 장비의 신뢰성 검증을 위한 정확성 및 정밀성에 대한 내용을 다룬다. 본 연구를 통해 개발한 장비의 정확성은 최종 판정기준인 1% 미만으로 매우 적합하였으며, 정밀성 또한 최종 판정기준을 모두 만족하여 매우 적합하다는 결과를 얻었다. 본 연구를 통해 개발된 편각 자동측정장비는 우수한 품질로 입증되어 캐노피 투명체의 국방규격에 등재되어 사용되고 있다.

Effect of different arch widths on the accuracy of three intraoral scanners

  • Kaewbuasa, Narin;Ongthiemsak, Chakree
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권4호
    • /
    • pp.205-215
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths. MATERIALS AND METHODS. Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed. RESULTS. Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes (P < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group. CONCLUSION. The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • 제44권4호
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

블레이드 각속도 통계 정보 기반 풍력 발전기 고장 진단 모니터링 시스템 (Statistical Blade Angular Velocity Information-based Wind Turbine Fault Diagnosis Monitoring System)

  • 김병진;강석주;박준영
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.619-625
    • /
    • 2016
  • 본 논문에서는 풍력 발전 시스템에서 발생 가능한 고장 중 블레이드에 대한 고장 진단 방법으로 자이로 센서를 이용한 각속도 측정을 통해 고장 진단용 모니터링 시스템을 제안한다. 제안하는 방법은 우선 손상이 발생하지 않은 상태의 블레이드 회전에 대한 각속도 dataset을 구성한다. 블레이드 상태 판별을 위한 dataset 구성이 되었다면, 임의의 상태에 대한 블레이드가 부착된 풍력 발전기를 일정한 힘을 가해 회전시킨 후 최종적으로 블레이드의 손상 정도에 따라 발생하는 각속도의 차이를 비교하여 블레이드의 고장 진단에 대해 판단한다. 실험 결과 정상 상태의 블레이드는 초당 1회 (초당 $360^{\circ}$) 이상의 속도로 회전을 진행하며, 손상 상태의 블레이드는 초당 1회 미만의 속도로 회전하며 표준 편차가 급격히 증가하는 것을 확인할 수 있었다.

Cone-beam CT를 이용한 안면비대칭자에서 이부편위에 따른 치성보상의 양상분석 (Correlation between menton deviation and dental compensation in facial asymmetry using cone-beam CT)

  • 박수병;박정희;정연화;조봉혜;김용일
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.300-309
    • /
    • 2009
  • 본 연구는 Cone-beam CT의 MPR이미지상에서 하악골 평면에 대한 하악 제1대구치와 견치의 편위측과 비편위측의 높이와 각도차이 그리고 FH 평면에 대한 상악 제1대구치와 견치의 편위측과 비편위측의 높이와 각도차이를 계측함으로써 안면비대칭자에서 이부편위에 따른 편위측과 비편위측의 제1대구치와 견치의 높이와 협설측 경사도를 CBCT를 이용하여 분석하고 그 관련성을 알아보는 데 있다. 연구대상은 하악골의 이부편위를 동반한 안면비대칭 환자 50명(여자 29명, 남자 21명, 평균나이 24세 4개월)으로 하였다. 대조군으로 평균나이 25세 7개월인 20명(남자 11명, 여자 9명)을 분석하였다. 결과는 이부편위에 대해 FH 평면에 대한 상악 제1대구치의 편위측과 비편위측의 길이 및 각도 차이(편위측 - 비편위측)는 대조군에 대해 통계적으로 유의한 차이가 존재하였다 (p < 0.01). 비대칭군에서 상악 제1대구치 각도는 편위측이 비편위측보다 평균 $8.62\;{\pm}\;5.95^{\circ}$ 컸다 (p < 0.01). 상악 견치의 경우에도 편위측과 비편위측의 각도차이가 평균 $4.48\;{\pm}\;5.05^{\circ}$로 통계적으로 유의한 차이가 존재하였다 (p < 0.01). 하악골 평면에 대한 하악 제1대구치의 수직 길이와 각도는 편위측과 비편위측에서 통계적으로 유의할 만한 차이가 존재하였다 (p < 0.01). 각도의 차이는 평균 $-11.92\;{\pm}\;5.79^{\circ}$로 나타났다. 이부편위에 대한 상하악 제1대구치와 견치의 수직거리 및 각도의 Pearson 상관분석 및 회귀분석 결과, FH 평면에 대한 상악 제1대구치의 편위측과 비편위측의 각도차이(${\Delta\angle}UM6$-FH plane (dev.-ndev.))는 통계적으로 유의한 양의 상관관계를 나타내었고, 하악골 평면에 대한 하악 제1대구치의 편위측과 비편위측의 각도차이(${\Delta\angle}LM6$-Mn plane (dev.-ndev.))는 통계적으로 유의한 음의 상관관계를 나타내었다. 이상의 결과에서 이부편위를 동반한 하악골 비대칭이 존재하는 경우, 이부가 편위되는 방향으로 상하악 제1대구치의 치아장축의 각도가 변화되는 것으로 나타났다.

개교교합의 두부방사선학적 연구 (A ROENTGENOCEPHALOMETRIC STUDY OF THE OPEN-BITE)

  • 서정훈
    • 대한치과의사협회지
    • /
    • 제16권12호통권115호
    • /
    • pp.923-928
    • /
    • 1978
  • The auther studied the open-bite of Hellman dental age IIIC groups of Korean childern on the roentgenocephalometry. The subjects consisted of 45 males and 45 females with normal occlusion and acceptable profile. The major conclusions may be listed as follows: 1. This study was summerized in the form of tables, mean, standard deviation, minium and maximum for 35 angular, linear and ration measurements. 2. Charts of standard deviation from the mesurements were made for the clinical application.

  • PDF

두부X선규격사진법에 의한 개교의 분석에 관하여 (STUDY OF THE ROENTGENOCEPHALOMETRIC ANALYSIS OF OPEN BITE)

  • 서정훈;유영세
    • 대한치과의사협회지
    • /
    • 제9권1호
    • /
    • pp.63-66
    • /
    • 1971
  • The authors studied the open bite of 100 Korean adults of both sexes with normal occlusion aged 20~23 using profile cephalometric roentgenogram. 1. This study was summarized in the form of tables, mean, standard deviation, minimum and maximum for 18 angular measurements. 2. For the clinical application of this research standard deviation chart for the 12 angles suitable to the study of open bite.

  • PDF

효율적인 상표 영상 검색 시스템 (System of Efficient Trademark Image Retrieval)

  • 신성윤;백정욱;이양원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.160-161
    • /
    • 2010
  • 본 논문에서는 컬러 정보와 형태 정보를 이용한 상표 영상 검색 시스템을 제안하였다. 컬러 정보는 영역을 분할하여 영역별 컬러 분포 히스토그램 특성에 근거한 컬러 정보를 이용하였고, 형태 정보는 경계면 추출, 무게 중심 추출, angular 샘플링 등의 전처리 과정과 무게 중심으로부터 경계면까지 거리의 합, 표준 편차, 장/단축 비율을 계산을 이용하였다. 특히, 무게중심을 이용한 angular 샘플링을 이용하여 특징을 추출하고 처리 시간을 줄일 수 있었다. 사용자는 컬러와 형태 정보에 의한 검색을 수행하고, 또한 가중치를 부여함으로써 두 방법을 혼합하여 사용할 수 있다.

  • PDF