• 제목/요약/키워드: Angular deviation

검색결과 95건 처리시간 0.028초

청소 로봇의 위치오차 보정 (The correction of clean robot position error)

  • 윤동우;오성남;김갑일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.533-535
    • /
    • 2006
  • Cleaning robot that is selling in present city has various cleaning algorithm. However, error of most products happens on progress direction by small obstacle that do not properly and miss cleaning thereby happens. There is robot that correct own position, but is hard to use in general home because economical strain is very big because is high price product very. In this paper measures angular velocity of robot using deviation sensor, and do to correct error using turning angular velocity and vertical angular velocity. Because detailed cleaning such as high pice style is available without addition of expensive hardware in middle and low price style cleaning product thereby, can possess price competitive power.

  • PDF

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권3호
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

횡단경사면에서 지능형 보행보조로봇의 직진성 향상 방안 연구 (The Study of Methods for Improve the Linearity of the Walking Assistant Robot to Move on Lateral Slopes)

  • 이원영;엄수홍;장문석;권오상;이응혁
    • 전자공학회논문지
    • /
    • 제50권1호
    • /
    • pp.261-268
    • /
    • 2013
  • 본 논문은 지능형 보행보조로봇이 횡단경사면주행에 있어 직진성 향상 알고리즘을 제안한다. 보행보조로봇은 횡단경사면주행시 로봇의 무게와 경사도에 의해 발생되어지는 회전모멘트의 영향을 받아 경로 이탈을 하게 된다. 이를 보정하기 위해 사용자가 입력하는 목표 회전각속도와 로봇의 회전각속도와의 비교를 통해 각 구동축에 가중치를 인가하는 알고리즘을 적용하였다. 제안한 보정 제어기를 실\제 보행보조로봇에 적용한 결과 횡단경사면 이동시 Yaw 축 이탈거리는 무보정 실험의 경우 발산하지만 Yaw 보정 알고리즘을 적용하였을 경우에는 이탈거리가 최대 20cm 이내로 안정적인 주행을 하는 것을 확인할 수 있었으며, 이탈거리 변화율 또한 300cm 이후 안정화되어 더 이상의 변화가 발생하지 않는 것을 확인할 수 있었다.

Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사 (Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement)

  • 김원;김승미;김효정;송은영;이시호;오남식
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.175-184
    • /
    • 2011
  • Computer-guided system은 술 전에 임플란트 위치를 계획하고 이와 일치하도록 구강 내에 임플란트를 식립할 수 있게 하는 방법이다. 하지만 이렇게 임플란트를 식립한다 할지라도 실제 매식된 임플란트의 위치는 원래 계획하였던 위치와 차이가 있을 수 있다. 이 연구의 목적은 실제 임상에서 computer guided system을 이용하여 임플란트를 식립한 환자들의 경우 계획한 위치와 실제 식립된 임플란트 사이에 발생하는 변위량의 범위를 알아보고 그 임상적 적합성을 평가하는 것이다. 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden)을 이용하여 Br${\aa}$nemark MK III Groovy RP (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden)임플란트 식립을 시행 받은 다섯 명의 환자를 선정하였다. 수술용 형판에 지대주 유사체를 연결한 후 술 전 측정 모형을 제작하였고 최종 보철물 제작 시 최종 인상을 채득하여 술 후 측정 모형을 제작하였다. 두 측정 모형의 CT 방사선 사진을 촬영 후 3차원적으로 재현하였고 재현된 모델 상에서 식립된 임플란트 위치를 지정하였다. 각 임플란트는 임플란트 경부와 첨단의 중심점을 연결하여 임플란트 축을 설정하였으며 두 축 간의 각도가 측정되었다. 임플란트 간 거리는 각 임플란트의 경부에서, 설정된 임플란트 축이 지나가는 중심점 간의 거리를 측정하였다. 총 5명 환자의 58개 부위의 임플란트 간 술 전과 술 후 임플란트 거리와 각도 변위량이 기록되었으며 평균 및 최대 변위값을 산출하였다. 술 전과 술 후 임플란트 위치 간 거리의 변위량은 평균 0.41 mm였고 최대 1.7 mm의 범위 하에 있었다. 술 전과 술 후 임플란트 간 위치의 각도의 변위량은 평균 $1.99^{\circ}$를 나타냈으며 최대 각도 변위량은 $6.7^{\circ}$를 나타내었다. 술 전 계획된 임플란트와 술 후 식립된 임플란트 간의 길이와 각도에 따른 평균 변위량은 computer-guided implant system을 실제 임상에 적용하는 데 있어 큰 문제가 존재하지 않고 '수동적 적합(passive fit)'을 얻기에 무리가 없을 허용 가능할 만한 값을 나타냈다.

컬러와 형태에 기반을 둔 상표 영상 검색 시스템 (The Brand Image Retrieval System Based on Color and Shape)

  • 신성윤;표성배
    • 한국컴퓨터정보학회논문지
    • /
    • 제11권3호
    • /
    • pp.167-172
    • /
    • 2006
  • 영상 검색 시스템이란 영상이 갖는 다양한 특징을 바탕으로 똑같거나 유사한 영상을 검색하여 제공하는 시스템이다. 본 논문에서는 영상의 컬러와 형태를 기반으로 한 상표 영상 검색 시스템을 제시한다. 영상을 영역별로 분할하고 영역별 컬러 분포 히스토그램을 추출하여 컬러 정보로 이용한다. 경계면 추출, 무게 중심 추출, angular 샘플링 등의 전처리 과정과 무게 중심으로부터 경계면 까지 거리의 합, 표준 편차, 장/단축 비율을 계산하여 형태정보로 이용한다. 이렇게 추출된 컬러와 형태 정보를 이용하여 유사성 측정을 통한 검색을 수행한다.

  • PDF

3D 메쉬 모델의 쉐이딩 시 시각적 왜곡을 방지하는 법선 벡터 압축에 관한 연구 (The Compression of Normal Vectors to Prevent Visulal Distortion in Shading 3D Mesh Models)

  • 문현식;정채봉;김재정
    • 한국CDE학회논문집
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2008
  • Data compression becomes increasingly an important issue for reducing data storage spaces as well as transmis-sion time in network environments. In 3D geometric models, the normal vectors of faces or meshes take a major portion of the data so that the compression of the vectors, which involves the trade off between the distortion of the images and compression ratios, plays a key role in reducing the size of the models. So, raising the compression ratio when the normal vector is compressed and minimizing the visual distortion of shape model's shading after compression are important. According to the recent papers, normal vector compression is useful to heighten com-pression ratio and to improve memory efficiency. But, the study about distortion of shading when the normal vector is compressed is rare relatively. In this paper, new normal vector compression method which is clustering normal vectors and assigning Representative Normal Vector (RNV) to each cluster and using the angular deviation from actual normal vector is proposed. And, using this new method, Visually Undistinguishable Lossy Compression (VULC) algorithm which distortion of shape model's shading by angular deviation of normal vector cannot be identified visually has been developed. And, being applied to the complicated shape models, this algorithm gave a good effectiveness.

상하악 악교정수술 후 입술 기울기변화 (CHANGE OF LIP CANTING AFTER BIMAXILLARY ORTHOGNATHIC SURGERY)

  • 이준휘;홍종락;김영호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권6호
    • /
    • pp.643-647
    • /
    • 2007
  • Purpose: The purpose of study was to investigate the correlationship between lip canting change and occlusal canting change after bimaxillary orthognathic surgery, and the ratio of lip canting change and occlusal canting change after the surgery. Patients and methods: The subjects for this study was obtained from a group of 25 patients who took bimaxillary orthognathic surgery for occlusal canting correction at the Department of the Oral and Maxillofacial Surgery, Samsung Medical Center in Seoul, Korea between January 2000 and December 2005 and a patient's chart had to contain a resting frontal facial photograph in natural head position and a corresponding PA cephalogram in occlusion on the same day before the surgery and post-op 6 months later. The lip canting change was assessed with the angle each labial commissure and the bipupilary reference line. And, the occlusal caning change in the frontal plane was assessed with the angle between the each maxillary first molar occulasal surface and the bi-frontozygomatic suture reference line. Results: In angular measurement, average occlusal canting change was $3.09^{\circ}$ and standard deviation was $1.05^{\circ}$, average lip canting change was $1.56^{\circ}$ and standard deviation was $1.05^{\circ}$. In linear measurement, average occlusal canting change was 2.41mm and standard deviation was 2.75mm, average lip canting change was 1.18mm and standard deviation was 0.43mm. Lip canting correction ration to occlusal canting correction was 51.5(${\pm}8.4$)% in angular measurement and 48.8(${\pm}9.1$)% in linear measurement. Under Pearson's correlation analysis, Pearson's correlation coefficient was 0.869 in angular measurement and 0.887 in linear measurement(p-value < 0.01). High correlationship was shown between occlusal canting change and lip canting change. Conclusion: First, Bimaxillary orthognathic surgery can correct lip canting as well as occlusal canting. Second, The average amount of lip canting correction is $51.5{\pm}8.4%,\;48.8{\pm}9.1%$ of occlusal canting correction in the study.

3-D CT를 이용한 악교정술 전후의 하악과 설골의 위치에 관한 연구 (THE POSITIONAL RELATIONSHIP BETWEEN THE MANDIBLE AND THE HYOID BONE IN MANDIBULAR PROTRUSION AFTER ORTHOGNATHIC SURGERY EVALUATED WITH 3-D CT)

  • 이상한;남정훈;정창욱;권대근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권3호
    • /
    • pp.173-181
    • /
    • 2003
  • Purpose : This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. Materials and methods : Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT & cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me & H, long axis angle of left & right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me & H. The angular & lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA & FH-NB, and coordinates(x,y) of B, Pog, Me & H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. Results : The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me'& H' were revealed the strong positive correlation. Conclusion : The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.

제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드 (Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides)

  • 권창렬;최병호;정승미;주상돈
    • 대한치과보철학회지
    • /
    • 제50권4호
    • /
    • pp.271-278
    • /
    • 2012
  • 연구 목적: 최근 정확하면서도 외상이 적은 임플란트 식립을 위해 임플란트 수술용 가이드가 많이 쓰이고 있다. 그 중 대표적인 방식이 stereolithography 방식과 positioning device로 제작한 방식이다. 본 연구는 이 두 가지 방식의 정확성을 비교하기 위하여 4 가지 형태의 치아상실 모델에서 실험 후 정확성에 관하여 분석하였다. 연구 재료 및 방법: 4가지 형태 치아 결손 모델 각각에 대하여 stereolithography 방법과 positioning device를 이용한 방법으로 수술 가이드를 제작하였다. 제작된 수술 가이드를 제작에 사용되었던 치아모델에 장착하여 수술 가이드의 내면과 모델의 치아표면 사이 공간크기를 측정하여 가이드의 적합도를 평가하였다. 또한 이 수술 가이드를 이용하여 총 40개 모델에서 임플란트 시술을 진행하고, 시술 후 모델을 다시 cone-beam computed tomography촬영 하여 수술 전후 영상을 중첩시켜 계획 상의 임플란트와 실제 시술한 임플란트의 위치를 비교하였다. 통계학적인 검증을 위하여 PASW Statistics$^{(R)}$ 18.0을 이용하여서 Mann-Whitney U 검정을 사용하였다. 결과: 수술 가이드 내면과 모델 사이 공간크기가 stereolithography는 $1.4{\pm}0.3mm$이고, positioning device는 $0.4{\pm}0.3mm$로 통계학적으로 유의한 차이를 보였다(P<.05). Stereolithography는 오차가 근원심 측에서 $3.9{\pm}1.6^{\circ}$, 협설 측에서 $2.7{\pm}1.5^{\circ}$, 깊이에서 $1.9{\pm}0.9mm$였다. 반면 positioning device는 오차가 근원심 측에서 $0.7{\pm}0.3^{\circ}$였고, 협설측에서 $0.3{\pm}0.2^{\circ}$, 깊이에서 $0.4{\pm}0.2mm$였다. 두 수술 가이드 제작방법은 모든 방향에서의 오차에서 통계학적으로 유의한 차이를 보였다(P<.05). 결론: 본 연구의 결과는stereolithography방법보다 positioning device를 이용하여 수술 가이드를 제작할 때 C.T.와 임플란트 치료 계획 프로그램을 이용하여 미리 계획한 임플란트 식립 위치와 방향으로 더 정확하게 식립 할 수 있음을 보여 주었다.

중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구 (The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error)

  • 조봉혜
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF