• 제목/요약/키워드: Angular Variations

검색결과 92건 처리시간 0.025초

집중 질량을 가진 회전하는 외팔 평판의 진동 해석 (Vibration Analysis of Rotating Cantilever Plates with a Concentrated Mass)

  • 양정식;유홍희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.181-186
    • /
    • 1998
  • A modelling method for the vibration analysis of rotating cantilever plates with a concentrated mass is presented. The equations of motion for the rotating plates with a concentrated mass located in an arbitrary position are derived. For the modelling of the concentrated mass, a mass density Dirac delta function is used. The effects of concentrated mass and its location, angular speed, and hub radius of the rotating plate on the natural frequencies are studied. Particularly, mode shape variations due to some parameter variations are investigated.

  • PDF

영구자석 동기전동기의 퍼지 속도제어기 및 퍼지 각가속도 관측기 설계 (Design of a Fuzzy Speed Controller and a Fuzzy Angular Acceleration Observer for a Permanent Magnet Synchronous Motor)

  • 정진우;최영식
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.103-112
    • /
    • 2011
  • This paper proposes a new fuzzy speed controller for the precise speed control of a permanent magnet synchronous motor(PMSM). The proposed control system needs the information of the angular acceleration instead of the load torque, so the third-order fuzzy acceleration observer estimates it. Moreover, the LMI conditions are derived for the existence of the fuzzy acceleration observer and fuzzy speed controller, and the gain matrices of the observer and controller are obtained. It is analytically proven that the proposed observer-based fuzzy speed regulator is exponentially stable. To evaluate the performance of the proposed control algorithm, experimental results as well as simulation results are provided under the conditions of motor parameter and load torque variations. Finally, it is clearly confirmed that the proposed control method can accurately control the speed of a PMSM.

Unsteady Subsonic Aerodynamic Characteristics of Wing in Fold Motion

  • Jung, Yoo-Yeon;Kim, Ji-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제12권1호
    • /
    • pp.63-68
    • /
    • 2011
  • Aerodynamic characteristics of a wing during fold motion were investigated in order to understand how variations or changes in such characteristics increase aircraft performance. Numerical simulations were conducted, and the results were obtained using the unsteady vortex lattice method to estimate the lift, drag and the moment coefficient in subsonic flow during fold motion. Parameters such as the fold angle and the fold angular velocity were summarized in detail. Generally, the lift and pitching moment coefficients decreased as the angle increased. In contrast, the coefficients increased as the angular velocity increased.

Heat Generation of Angular Contact Ball Bearings

  • Rhim, Yoon-Chul;Na, Hee-Hyeong
    • Tribology and Lubricants
    • /
    • 제11권5호
    • /
    • pp.122-127
    • /
    • 1995
  • The heat generations of angular contact ball bearings are studied experimentally with numerical simulations. The temperature variations of inner and outer races and the temperature increase distributions are measured by using thermocouples for the spindle rotational speeds, preloads, viscosity of oils, and lubrication methods. The measured values from experiments are used to estimate the heat generation rates. The heat generation is focused mainly on the dominant sources which are robbings due to spin and gyro-moments of bearing balls, applied load and viscous friction. Oil-jet and oil-air lubrication methods are adopted using oils with different viscosities.

Development and physiological assessments of multimedia avian esophageal catheter system

  • Nakada, Kaoru;Hata, Jun-ichi
    • Journal of Multimedia Information System
    • /
    • 제5권2호
    • /
    • pp.121-130
    • /
    • 2018
  • We developed multimedia esophageal catheters for use with birds to measure and record ECG and angular velocity while anesthesized, at rest, and in flight. These catheters enable estimates of blood pressure based on readings given by an angular velocity sensor and by RR intervals of ECG affected by EMG. In our experiments, the catheters had the following characteristics: 1. Esophageal catheters offer a topological advantage with 8-dB SNR improvement due to elimination of electromyography (EMG). 2. We observed a very strong correlation between blood pressure and the angular velocity of esophageal catheter axial rotation. 3. The impulse conduction pathway (Purkinje fibers) of the cardiac ventricle has a direction opposite to that of the mammalian pathway. 4. Sympathetic nerves predominate in flight, and RR interval variations are strongly suppressed. The electrophysiological data obtained by this study provided especially the state of the avian autonomic nervous system activity, so we can suspect individual's health condition. If the change of the RR interval was small, we can perform an isolation or screening from the group that prevent the pandemics of avian influenza. This catheter shall be useful to analysis an avian autonomic system, to perform a screening, and to make a positive policy against the massive infected avian influenza.

Shape Description and Retrieval Using Included-Angular Ternary Pattern

  • Xu, Guoqing;Xiao, Ke;Li, Chen
    • Journal of Information Processing Systems
    • /
    • 제15권4호
    • /
    • pp.737-747
    • /
    • 2019
  • Shape description is an important and fundamental issue in content-based image retrieval (CBIR), and a number of shape description methods have been reported in the literature. For shape description, both global information and local contour variations play important roles. In this paper a new included-angular ternary pattern (IATP) based shape descriptor is proposed for shape image retrieval. For each point on the shape contour, IATP is derived from its neighbor points, and IATP has good properties for shape description. IATP is intrinsically invariant to rotation, translation and scaling. To enhance the description capability, multiscale IATP histogram is presented to describe both local and global information of shape. Then multiscale IATP histogram is combined with included-angular histogram for efficient shape retrieval. In the matching stage, cosine distance is used to measure shape features' similarity. Image retrieval experiments are conducted on the standard MPEG-7 shape database and Swedish leaf database. And the shape image retrieval performance of the proposed method is compared with other shape descriptors using the standard evaluation method. The experimental results of shape retrieval indicate that the proposed method reaches higher precision at the same recall value compared with other description method.

집중 질량을 가진 회전하는 외팔 평판의 진동 해석 (Vibration Analysis of Rotating Cantilever Plates with a Concentrated Mass)

  • 양정식;유홍희
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1130-1136
    • /
    • 1998
  • A modelling method for the vibration analysis of rotating cantilever plates with a concentrated mass is presented. The equations of motion for the rotating plates with a concentrated mass located in an arbitrary position are derived and transformed into a dimensionless form. For the mathematical modelling of the concentrated mass. a mass density Dirac delta function is used. The effects of concentrated mass and its location. angular speed. plate aspect ratio. and hub radius of the rotating plate on the natural frequencies are studied. Particularly. mode shape variations due to some parameter variations are investigated.

  • PDF

회전 외팔보의 면외방향 굽힘진동 해석 (Flapwise Bending Vibration of Rotating Cantilever Beams)

  • 유홍희
    • 대한기계학회논문집
    • /
    • 제19권2호
    • /
    • pp.348-353
    • /
    • 1995
  • When cantilever beams rotate, their bending stiffnesses change due to the stretching caused by centrifugal inertia forces. Such phenomena result in variations of natural frequencies and mode shapes associated with constant speed rotational motions of the beams. These variations are important in many practical applications such as helicopter blades, turbomachines, and space structures. This paper presents the formulation of a set of linear equations governing the flapwise bending vibration of rotating cantilever beams. These equations can be used to provide accurate predictions of the variations of natural frequencies and mode shapes due to rotation.

Anatomical study of divergences in facial artery endings

  • Yasser Ayish Alharbi
    • Anatomy and Cell Biology
    • /
    • 제56권2호
    • /
    • pp.211-218
    • /
    • 2023
  • Despite several studies focusing on the facial arteries variable courses, the findings have significantly differed. The divergent findings have made it increasingly challenging to establish consistent correlations. Thus, as a vital artery, the facial artery is prone to numerous variations, which makes the identification of the variations vital to clinical practice, particularly for the orofacial and rhinoplastic surgery, and the increasingly selective chemotherapy procedures. The present research uses angiography images for analysis in studying the bilateral facial artery variations noted in patients undergoing carotid angiography for the evaluation of congenital anomalies, cerebral vascular malformations, and intra-arterial procedures. Conventional angiography was used, as it is a vital assessment tool that helps in the assessment of variations in the facial arteries and is suitable in evaluating smaller vascular anatomy, due to the perfect spatial resolution and portrayal of vascular anatomy. Thus, rather than normal ending of the facial artery as an angular artery, the study disclosed that in certain instances, the artery termination took the form of a superior labial artery with a small lateral nasal artery branch located closer to the midline compared to the normal cases. Also, the study has disclosed a conspicuous pre-masseteric branch with small branches originating from the infraorbital artery and providing potential compensation for the facial artery's shortness. Regardless of the infrequency of such variations, it is vital that they are considered during the performance of any facial surgical procedure.

Three-Dimensional Evaluation of Skeletal Stability following Surgery-First Orthognathic Approach: Validation of a Simple and Effective Method

  • Nabil M. Mansour;Mohamed E. Abdelshaheed;Ahmed H. El-Sabbagh;Ahmed M. Bahaa El-Din;Young Chul Kim;Jong-Woo Choi
    • Archives of Plastic Surgery
    • /
    • 제50권3호
    • /
    • pp.254-263
    • /
    • 2023
  • Background The three-dimensional (3D) evaluation of skeletal stability after orthognathic surgery is a time-consuming and complex procedure. The complexity increases further when evaluating the surgery-first orthognathic approach (SFOA). Herein, we propose and validate a simple time-saving method of 3D analysis using a single software, demonstrating high accuracy and repeatability. Methods This retrospective cohort study included 12 patients with skeletal class 3 malocclusion who underwent bimaxillary surgery without any presurgical orthodontics. Computed tomography (CT)/cone-beam CT images of each patient were obtained at three different time points (preoperation [T0], immediately postoperation [T1], and 1 year after surgery [T2]) and reconstructed into 3D images. After automatic surface-based alignment of the three models based on the anterior cranial base, five easily located anatomical landmarks were defined to each model. A set of angular and linear measurements were automatically calculated and used to define the amount of movement (T1-T0) and the amount of relapse (T2-T1). To evaluate the reproducibility, two independent observers processed all the cases, One of them repeated the steps after 2 weeks to assess intraobserver variability. Intraclass correlation coefficients (ICCs) were calculated at a 95% confidence interval. Time required for evaluating each case was recorded. Results Both the intra- and interobserver variability showed high ICC values (more than 0.95) with low measurement variations (mean linear variations: 0.18 mm; mean angular variations: 0.25 degree). Time needed for the evaluation process ranged from 3 to 5 minutes. Conclusion This approach is time-saving, semiautomatic, and easy to learn and can be used to effectively evaluate stability after SFOA.