• Title/Summary/Keyword: Angle-angle Diagram

Search Result 111, Processing Time 0.023 seconds

Mixed-state Hall angle Hg-based superconducting thin films

  • Kim, Wan-Seon;Lee, Sung-Ik;Kang, Won-Nam
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.41-44
    • /
    • 2000
  • The mixed-state Hall angle has been measured in Hg-based superconducting thin films as functions of magnetic fields (H) up to 18 T. The temperature dependence of the Hall angle shows a peak (T$^{\ast}$) at low temperature, which is consistent with a crossover point from the thermally activated flux flow (TAFF) to a critical region (CR). At low fields below 10 T, T$^{\ast}$ shifts to low temperature with increasing fields. Interestingly, however, we found that T$^{\ast}$ is independent of fields above 10 T, suggesting unusual vortex state. A physical implication of H - T$^{\ast}$ line will be discussed.

  • PDF

Mixed-state Hall Angle in Hg-based Superconducting Thin Films

  • Kang, Won-Nam;Kim, Wan-Seon;Lee, Sung-Ik
    • Progress in Superconductivity
    • /
    • v.2 no.1
    • /
    • pp.39-42
    • /
    • 2000
  • The mixed-state Hall angle has been measured in Hg-based superconducting thin films as functions of magnetic fields (H) up to 18 T. The temperature dependence of the Hall angle shows a peak (T*) at low temperature, which is consistent with a crossover point from the thermally activated flux flow (TAFF) to a critical region (CR). At low fields below 10 T, T* shifts to low temperature with increasing fields. Interestingly, however, we found that T* is independent of fields above 10 T, suggesting unusual vortex state. A physical implication of H-T* line will be discussed.

  • PDF

A Study on the Position Accuracy Improvement Applying the Rectangular Navigation in the Hyperbolic Navigation System Area. (쌍곡선항법시스템을 이용한 직각항법에 의한 측위정도 향상에 관한 연구)

  • 김우숙;김동일;정세모
    • Journal of the Korean Institute of Navigation
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 1989
  • Nowadays Hyperbolic Navigation System-LORAN, DECCA, OMEGA, OMEGA-is available on the ocean, and Spherical Navigation System, GPS (Global Positioning System) is operated partially. Hyperbolic Navigation System has the blind area near the base line extention because divergence rate of hyperbola is infinite theoretically. The Position Accuracy is differ from the cross angle of LOP although each LOP has the same error of quantity. GDOP(Geometric Dilution of Precisoin) is used to estimate the position accuracy according to the cross angle of LOP and LOP error. Hyperbola and ellipse are crossed at right angle everywhere. Hyperbola and ellipse are used to LOP in Rectangular Navigation System. The equation calculating the GDOP of rectangular Navigation System is induced and GDOP diagram is completed in this paper. A scheme that can improve the position accuracy in the blind area of Hyperboic Navigation System using the Rectangular Navigation System is proposed through the computer simulation.

  • PDF

A Research on Curved Display Comparing to Flat Display Regarding Posture, Tilt Angle, Focusing Area and Satisfaction

  • Ahn, Sung Hee;Jin, Byungki;Kwon, Sanghyun;Yun, Myung Hwan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.3
    • /
    • pp.191-202
    • /
    • 2014
  • Objective: This study is conducted on the differences between flat and curved displays with respect to location of focused points, posture and satisfaction as well as preferred tilt angles. Background: In order to avoid physical and eye fatigue caused by misplayed sitting posture, many studies have asserted that the display requires appropriate location, size and tilt angle as well as curvature. However, most studies have focused on the work environment and the results are varied in the extent. Method: Eye height data in sitting posture were collected from 30 participants. Participants selected the most comfortable viewing angle within the range from $0^{\circ}$ to $12^{\circ}$ while watching videos for both curved and flat display. Then, physical and eye fatigue and overall satisfaction were subjectively evaluated. Lateral diagram describing viewing display condition was set and used to develop linear models for expecting the preferred tilt angle. Results: Due to sitting in the natural viewing posture rather than upright, the eye height is lowered to about 4.6 centimeters, on average, for both displays showing no significant differences. In contrast, preferred angles for the two displays are significantly different and this can be interpreted that curvature vary the points focused. Two linear models as functions of sitting eye height are developed to expect preferred tilt angle for each display. Based on the result of overall satisfaction evaluation, curved display is statistically better than flat display. Conclusion: The results show that flat and curved displays are significantly different expect for the viewing posture. However, reasons for preferring curved display are not accurately factorized and the linear models are limited in the experiment condition such as size of display, distance between display and viewer and other physical environmental factors. Further studies on curved displays under more various conditions are required. Application: This study can contribute to use of the curved display in various way.

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

Performance Improvement Method of an Axial Fan Using Simulation (시뮬레이션을 이용한 축류팬 성능 개선 방법)

  • Lim, Hyo Mok;Yun, Dong Gyu;Yim, Choong Hyuk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.1
    • /
    • pp.137-143
    • /
    • 2017
  • An axial fan has competitive advantages that can make air flow more straight and longer and produce larger air volume than the other kinds of fans. In those reasons, axial fans are widely used for ventilator, 4D cinema, duct, and so on. But, as it was designed and manufactured without any mathematical analysis or computer simulations, it is difficult to develop the performance of axial fans. Actually the axial fan is designed and manufactured in industry by imitation or traditional method. Flow velocity and volume of axial fan are changed by pitch angle, frame, the number of blade, camber angle, and chord length. In this paper, the performance of axial fan was analyzed and by computer program known as CFD. Finally, we have designed a new axial fan whose velocity and volume is improved. The performance of new axial fan is also compared with the of conventional fans experimentally.

Effects of pH and the Existence of CO2 Gas on the Silica Surface Characteristics at Silica/Pb(II) Solution Interface (CO2 가스의 존재 여부와 용액의 pH가 Silica/Pb(II) 용액 계면에서 Silica 표면의 특성에 미치는 영향)

  • Lee, Sang-Eun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.5
    • /
    • pp.263-271
    • /
    • 2003
  • Effects of the existence of $CO_2$ gas and pH on the silica surface characteristics at silica/Pb(II) and sodium dodecyl sulfonate (SDS, $C_{12}H_{25}SO_3Na$) solution interface were studied. The hydrophobic characteristics of silica surface was delineated by contact angle measurement and surface force measurement using atomic force microscopy (AFM). In $CO_2$ free condition provided by purging $N_2$ gas, the contact angle of fused silica surface in $10^{-4}M$ Pb(II) and SDS solution increased greatly up to $90^{\circ}$ compared with $40^{\circ}$ in atmospheric condition. It was due to the precipitation of $PbCO_3$ in atmospheric condition. In $CO_2$ free condition the change of contact angle and adhesion force ($F_{ad}$) in AFM, affected by pH change, was similar to the distribution of $PbOH^+$ ion in speciation diagram corresponding to $10^{-4}M$ total Pb(II). Therefore, it was convinced that the $PbOH^+$ ion among Pb(II) species would be the main adsorbing type on silica surface. Both of contact angle measurement and surface force measurement using AFM showed that the Pb only treatment made the silica surface hydrophobic. However, it could not be explained theoretically by current knowledge, and required further study in atomic level to solve the problem.

Prediction of Fatigue Life in 2024-73 Aluminum Using X-ray half-value breadth

  • Kim, Soon-Ho;Cho, Seok-Swoo;Park, Jung-Hyeon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.2
    • /
    • pp.78-86
    • /
    • 2002
  • In general, X-ray diffraction method detects the changes of crystal lattice under material surface using the angle of diffraction 2$\theta$. This technique which deals with in the presented paper can be applied to a behavior on the slipped band or the micro crack cause to material degradation. The relation between half-value breadth and cycle numbers shows three stages, which consist of rapid decrease in the initial cycle, slight decrease in the middle cycle, and then rapid decrease in the final cycle. The ratio of half-value breadth has a constant value on B/B$\_$0/ - N diagram under the loading condition except early part of fatigue life. The ratio of half-value breadth B/B$\_$0/ - log N$\_$f/ with respect to number of cycle to failure N$\_$f/ has linear behavior on B/B$\_$0/ - log N$\_$f/ diagram. Therefore, the evaluation of fatigue life by the average gradient has much less mean error than the estimation of fatigue life by log B/B$\_$0/ - log N/N$\_$f/ relation.

A Study on the Measurement of Residual Stress in Rolled Steel for Automobile using X-ray Diffraction (X선 회절을 이용한 자동차 압연강의 잔류응력 측정에 관한 연구)

  • 홍순혁;이동우;조석수;주원식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.150-157
    • /
    • 2002
  • In textured material, diffraction angle $2{\theta}$ usually shows a nonlinear relation against $sin^2{\psi}$ due to elastic anisotropy of crystals. SPHD and SPCD steel is cold-rolled carbon steel for automobile. The characteristics X-ray for stress measurement is Cr $K_{\alpha}\;and\;Mo\;K_{\alpha}$ characteristic X-ray. The $2{\theta}-sin^2{\psi}$ diagram under elastic strain seems to have a linear behavior using regression line of data but has a nonlinear behavior in distribution of data by Cr $K_{\alpha}$ characteristic X-ray. As the plastic strain of specimen increases, the nonlinearity of $2{\theta}$ with respect to $sin^2{\psi}$ increases remarkably. On the other hand, the diffraction angle $2{\theta}$ by Mo $K_{\alpha}$ characteristic X-ray shows a good linearity on $2{\theta}-sin^2{\psi}$ diagram under plastic strain as well as elastic strain. Therefore, this paper presents the measurement of residual stress in cold-rolled carbon steel for automobile using penetration depth of Mo $K_{\alpha1}$ characteristic X-ray and multiplicity factor of crystal diffraction plane.

A Study on the Prediction of Fatigue Life in 2024-T3 Aluminium using X-ray Half-Value Breadth (X선 반가폭을 이용한 Al 2024-T3 합금의 피로수명예측에 관한 연구)

  • 조석수;김순호;주원식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.145-152
    • /
    • 2000
  • X-ray diffraction method detects change of crystal lattice distance under material surface using diffraction angle 2$\theta$. This technique can be applied to the behavior on slip band and micro crack due to material degradation. The relation between half-value breadth and number of cycle has three stages which constitute rapid decrease in initial number of cycles, slight decrease in middle number of cycles and rapid decrease in final number of cycles. The ratio of half-value breadth takes a constant value on B/B$_{0}$-N diagram with loading condition except early part of fatigue life. The ratio of half-value breadth B/B$_{0}$ with respect to number of cycle to failure N$_{f}$ has linear behavior on B/B$_{0}$-log N$_{f}$ diagram. Therefore, in this paper the estimation of fatigue life by average gradient method has much less estimated mean error than the estimation of fatigue life by log B/B$_{0}$-log N/N$_{f}$ relation.elation.ation.

  • PDF