• Title/Summary/Keyword: Angle standard

Search Result 931, Processing Time 0.027 seconds

Vehicle Heading Angle Determination Using Magnetometer

  • Lee, Seon-Ho;Ahn, Hyo-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1259-1261
    • /
    • 2003
  • The vehicle's heading angle determination is formulated and the proposed method based on geometry engages the magnetometer and the GPS. The resulting maximum determination accuracy of 0.3deg over the entire earth as a standard deviation is obtained for a magnetometer with measurement error of 1nT.

  • PDF

Performance Variations of Vaned Diffusers with Solidity and Exit Vane Angle (베인 디퓨저의 솔리디티와 출구 유동각에 따른 성능변화)

  • Cho, S.K.;Kang, S.H.;Cha, B.J.;Lee, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.422-427
    • /
    • 2000
  • The design of low-solidity vaned diffusers and the effect on the performance of a turbocharger compressor is discussed. The effect of vane number and turning angle was investigated while maintaining a basic design with a leading edge angle of $70^{\circ}$, leading and trailing edge radius ratios of 1.1 and 1.3. All results are compared with those obtained with the standard vaneless diffuser configuration and it was shown that all designs increased and shifted the pressure ratio to reduced flowrates. Despite the low-solidity configuration none of the vane designs provided a broad operating range, and the vane leading edge angle was not main factor that system went into the surge condition. The diffuser of higher trailing edge angle improved the flow range for the compressor to operate at lower flow region.

  • PDF

Angle-sensitive Pixels Based on Subwavelength Compound Gratings

  • Meng, Yunlong;Hu, Xuemei;Yang, Cheng;Shen, Xinyu;Cao, Xueyun;Lin, Lankun;Yan, Feng;Yue, Tao
    • Current Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.359-366
    • /
    • 2022
  • In this paper, we present a new design for angle-sensitive pixels (ASPs). The proposed ASPs take advantage of subwavelength compound gratings to capture the light angle, which enables pixel size to reach the wavelength scale of 0.7 ㎛ × 0.7 ㎛. The subwavelength compound gratings are implemented by the wires of the readout circuit inherent to the standard complementary metal-oxide-semiconductor manufacturing process, thus avoiding additional off-chip optics or post-processing. This technique allows the use of two pixels for horizontal or vertical angle detection, and can determine the light's angle in the range from -45° to +45°. The proposed sensor enables surface-profile reconstruction of microscale samples using a lensless imaging system.

Unbiased Estimators of Standard Deviation in a Truncated Arcsine Distribution

  • Woo, Jung-soo;Kim, Jung-dae;Lee, Chang-soo
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.2
    • /
    • pp.507-514
    • /
    • 1997
  • Three kinds of unbiased estimators of standard deviation in a truncated arcsine distribution based on the quasi-range, the jackknife quasi-range, and the angle jackknife range are proposed and numerically compared each other in a sense of MSE.

  • PDF

Effect of Walking Speed on Angles of Lower Extremity and Ground Reaction Force in the Obese (보행속도가 비만인의 하지관절각과 지면반발력에 미치는 영향)

  • Kim, Tae-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.4
    • /
    • pp.83-94
    • /
    • 2006
  • The purpose of this study is to elucidate how walking speed influences on change of angles of lower extremity and ground reaction force in normal and obese people. One group with normal body weight who were experimented at a standard speed of 1.5m/s and the other obese group were experimented at two different walking speeds (standard speed of 1.5m/s and self-selected speed of 1.3m/s). We calculated angles of lower extremity and ground reaction force during stance phase through video recording and platform force measuring. When the obese group walked at the standard speed, dorsi-flexion angle of ankle got bigger and plantar-flexion angle of ankle got smaller, which were not statistically significant. There was no significant difference of knee joint angles between normal and obese group at the same speed walking but significant post hoc only for the first flexion of knee joint in obese group. $F_z1$ was bigger than $F_z3$ in vertical axis for ground reaction force in both groups at the standard speed walking and the same force value at self-selected speed in obese group. $F_y3$ was always bigger than $F_y1$ in anterior-posterior axis in both groups.

Determination of Critical State Parameters in Sandy Soils from Standard Triaxial Testing (II) : Experiment and Recommendation (표준삼축시험으로부터 사질토에서의 한계상태정수 결정에 관한 연구 (II) : 실험 및 추천)

  • 조계춘
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.1
    • /
    • pp.77-92
    • /
    • 2003
  • A set of standard triaxial testing was performed to identify underlying physical processes and inherent limitations in the determination of critical state parameters in sandy soils. The experimental test results showed that the critical state friction angle for a given soil is constant regardless of drainage condition while the critical state line on the e-log p'space is significantly affected by drainage condition mainly because of insufficient strain attained in standard triaxial tests and strain localization effects in udrained tests. It appeared that the best method to determine critical state parameters in laboratory testing is to use homogeneous loose specimens under drained shear condition. In addition, a reference state parameter was suggested to design tests that will avoid dilatancy or strain localization effects in drained tests.

AN ANALYSIS OF SOFT TISSUE PROFILE (연조직 측모에 관한 분석)

  • Chang, Young-Il;Choi, Hee-Young;Shin, Soo-Jung
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.627-634
    • /
    • 1995
  • The purpose of this study to analyze characteristics of soft tissue profile in Korean young adults. The sample consisted of 50 young adults (25 males and B females) who had pleasing and normal occlusion. Soft tissue analysis (facial convexity angle, nasolabial angle, H-angle, Z-angle, E-line to upper lip, lower lip, Sn-pog' to upper lip, lower lip) was performed on lateral cephlograms. Mem and standard deviation was obtained. When compared by other studies, mean profile of this sample was relatively straighter and both the upper and lower lips was more protrusive.

  • PDF

A Study on the Analysis of Foot Shape (I) -on Classification of Foot Type- (발의 형태분석에 관한 연구(I) -발의 형 분류를 중심으로-)

  • Moon Myeng-ok;Kwon Young-suk
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.1 s.26
    • /
    • pp.45-52
    • /
    • 1988
  • To classify the foot type, direct measurements, metatarso-phalanx angle and foot print angle of the right and left foot were measured and analyzed. The results are as follows. 1. The correlation coefficients between right and left foot were high degree, and except medial malleous height, the diffences between right and left foot are not significant. 2. The correlation coefficient among direct measurements of the foot are high degree, tut the correlation coefficients between direct measurements and metatarso-phalanx angle and foot print angle are no or low degree. Therefore, to recognize the foot type, the direct measurements, metatarso-phalanx angle and foot print angle need to be measured independently. 3. According to foot width/foot $length{\times}100$ which is the slender degree of foot, three groups are distinguished: one is slender type of which foot width/foot $length{\times}100$ is less than $40.14\%$, two is standard type of which foot width/foot $length{\times}100$ is $40.14\%{\~}44.30\%$, three is broad type of which foot width/foot $length{\times}100$ is more than $44.30\%$. 4. On the photographs metatarso-phalanx angle was measured, and two groups are distinguished: one is normal type of which the metatarso-phalanx angle is more than $160^{\circ}$ and the other is the deformed type of which the metatarso-Phalanx angle is less than $159^{\circ}$. 5. By foot print angle $30^{\circ}$ which need reformation of the foot, two groups are distinguished: one is normal foot print angle of which the angle is more than $30^{\circ}$ and the other is flat foot print angle of which the angle is less than $30^{\circ}$. 6. Classifications by foot width/foot $length{\times}100$, metatarso-Phalanx angle and foot Print angle are put together, and then foot types are classified into 12 groups such as Table 11.

  • PDF

Development of the Optimized Angle Head for Internal Shape Machining Using Five-Axis Machine Tool (5축가공기를 활용한 내면 형상 가공용 최적 앵글헤드의 개발)

  • Hwang, Jong-Dae;Kim, Jae-Hyun;Cho, Young-Tae;Jung, Yoon-Gyo;Ko, Hae-Ju
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.1
    • /
    • pp.123-129
    • /
    • 2015
  • In general, recent critical studies of five-axis machine have tended to center on the question of effective machining to realize complex shape parts. However, the hydrostatic bearing and journal bearing, both of which are involved in the complex process of dividing the processing of internal precision-shape machining, must be optimized. Although the angle head is designed to machine the internal shape as it approaches the inner diameter of the work piece, research on the angle head in five-axis machining has received only minimal attention in domestic industries. In this study, an angle head which is optimized for effective internal shape machining is developed. In pursuit of this purpose, 3D and 2D designs of the angle head for five-axis machining are devised. Reliability is secured through static performance tests and machining accuracy evaluations of the angle head in keeping with the machining accuracy standard of 0.2mm for hydrostatic bearings.

Pullout Test Results of Geosynthetics using Granite Soil and Standard sand (화강토와 표준사를 이용한 토목섬유의 인발시험결과 비교)

  • Ju, Jae-Woo;Park, Jong-Beom;Kim, Jang-Heung;Song, Chun Seok;Baek, Kyung-Jong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.2
    • /
    • pp.39-45
    • /
    • 2005
  • New concept called the pullout resistance angle has been used to express the friction, cohesion and passive resistance by pullout test at geosynthetics reinforced soil. And also in order to calculate the pullout area, the distribution area method has been used, which is a method of using the curve of tensile force exerted in geogrid. The distribution area ratio showed nearly the same result in the two kind of soils, the granite soil and the standard soil. The pullout resistance angle showed the greater value than friction angle of soil in case of low confining stress of $0.2kg/cm^2$, while it showed the smaller angle than friction of soil in case of high confining stress of $0.8kg/cm^2$.

  • PDF