• Title/Summary/Keyword: Angle of tilt window

Search Result 8, Processing Time 0.026 seconds

The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation (투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.

A Comparison of Pelvic Tilt Before and After Manipulation of Sacroiliac Joint in the Patients with Low Back Pain (요통환자의 천장관절에 대한 도수교정 전과 후의 골반경사 비교)

  • Oh, Seung-Gil;Lee, Jin-Haeng
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.579-595
    • /
    • 2000
  • The purposes of this study were to compare pelvic tilt before and after manipulation of sacroiliac joint in 31 low back pain patients (11 males, 20 females) with sacroiliac joint dysfunction. The sacroiliac joint of patients was manipulated on the side of anterior pelvic tilt, using the technique described by Stoddard (1962) and Greenmann (1996). I used this technique because it usually eliminated sacroiliac joint dysfunction in one treatment session. SPSS for window computer system was used to analyze the data. Also t-test was performed for comparison of pelvic tilt angle before and after manipulation, and Pearson product-moment correlation analysis was performed for intratester reliability for measurements of pelvic tilt angle before and after manipulation. The result were as follows: 1. Intratester reliability was good for measures of pelvic tilt (r=.98). 2. The pelvic tilt after manipulation was significantly decreased (mean=$3.40^{\circ}$) compared with the pelvic tilt before manipulation (p=.001). All subjects showed asymmetrical right versus left pelvic tilt before manipulation. 40% of subjects showed decreased asymmetrical right versus left pelvic tilt after manipulation, and 60% of subjects showed symmetrical right versus left pelvic tilt after manipulation. I think that pelvic tilt asymmetry with hypomobility due to loss of joint play could be symmetrized by manipulation or mobilization, but pelvic tilt asymmetry with unilateral pelvic muscle shortening could not be symmetrized by manipulation or mobilization without relaxation and stretching of shortened muscles.

  • PDF

The Effects of Growth Temperature and Substrate Tilt Angle on GalnP/GaAs Tandem Solar Cells

  • Jun, Dong-Hwan;Kim, Chang-Zoo;Kim, Hog-Young;Shin, Hyun-Beom;Kang, Ho-Kwan;Park, Won-Kyu;Shin, Ki-Soo;Ko, Chul-Gi
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.91-97
    • /
    • 2009
  • The performance of GaInP/GaAs tandem solar cells with AlInP growth temperatures of 680$^{\circ}C$ and 700 $^{\circ}C$ on n-type GaAs (100) substrate with 2$^{\circ}$ and 6$^{\circ}$ tilt angles has been investigated. The series resistance and open circuit voltage of the fabricated tandem solar cells are affected by the substrate tilt angles and the growth temperatures of the window layer when zinc is doped in the tunnel diode. With carbon doping as a p-type doping source in the tunnel diode and the effort of current matching between top and bottom cells, GaInP/GaAs tandem solar cell has been exhibited 25.58% efficiency.

An Camera Information Detection Method for Dynamic Scene (Dynamic scene에 대한 카메라 정보 추출 기법)

  • Ko, Jung-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.275-280
    • /
    • 2013
  • In this paper, a new stereo object extraction algorithm using a block-based MSE (mean square error) algorithm and the configuration parameters of a stereo camera is proposed. That is, by applying the SSD algorithm between the initial reference image and the next stereo input image, location coordinates of a target object in the right and left images are acquired and then with these values, the pan/tilt system is controlled. And using the moving angle of this pan/tilt system and the configulation parameters of the stereo camera system, the mask window size of a target object is adaptively determined. The newly segmented target image is used as a reference image in the next stage and it is automatically updated in the course of target tracking basing on the same procedure. Meanwhile, a target object is under tracking through continuously controlling the convergence and FOV by using the sequentiall extracted location coordinates of a moving target.

Multi-Time Window Feature Extraction Technique for Anger Detection in Gait Data

  • Beom Kwon;Taegeun Oh
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.4
    • /
    • pp.41-51
    • /
    • 2023
  • In this paper, we propose a technique of multi-time window feature extraction for anger detection in gait data. In the previous gait-based emotion recognition methods, the pedestrian's stride, time taken for one stride, walking speed, and forward tilt angles of the neck and thorax are calculated. Then, minimum, mean, and maximum values are calculated for the entire interval to use them as features. However, each feature does not always change uniformly over the entire interval but sometimes changes locally. Therefore, we propose a multi-time window feature extraction technique that can extract both global and local features, from long-term to short-term. In addition, we also propose an ensemble model that consists of multiple classifiers. Each classifier is trained with features extracted from different multi-time windows. To verify the effectiveness of the proposed feature extraction technique and ensemble model, a public three-dimensional gait dataset was used. The simulation results demonstrate that the proposed ensemble model achieves the best performance compared to machine learning models trained with existing feature extraction techniques for four performance evaluation metrics.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

Magnetic Sector SIMS의 Sample Holder 위치에 따르는 RSF (Relative Sensitivity Factor) 변화 검증

  • 홍성윤;이종필;홍태은;윤명노;민경열;이순영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.192-192
    • /
    • 1999
  • SIMS(Secondary Ion Mass Spectrometry)는 다른 표면 분석장비와 비교하여^g , pp m,^g , pp b 단위의 미량분석이 가능한 장비로서, 특히 depth Profiling을 위한 dynamic SIMS는 Mass Spectrometer의 종류에 따라 Quadrupole SIMS (Q-SIMS)와, Magnetic Sector SIMS (M-SIMS)로 분류된다. 한편, Q-SIMS와 달리 M-SIMS의 경우, Transmission을 높여 주기 위해 Sample Holder에 수 keV의 bias를 걸어 주는데, 이로 인하여 분석 원소에 대한 Sensitivity가 향상되어 지는 반면, RSF의 변화와 같은 분석상의 Artifact가 발생하게 된다. 일반적으로 Q-SIMS의 경우에는 RSF의 RSD(Relative Standard Deviation)가 1%이내에서 보고되고 있지만 M-SIMS에 있어서는 이러한 Deviation이 M-SIMS보다 크게 나타난다. 이 차이는 주로 Sample Holder와 Immersion Lens 사이에 형성되는 Magnetic Field의 왜곡과 Spectrometer의 문제로부터 발생한다. 본 논문에서는 Sample Holder의 종류 및 holder so window 위치에 따라 RSF의 차이를 측정하고 그 data를 RS/1 통계 Package를 이용하여 계량적으로 검증하였으며, 그 차이의 원인과 대책을 제시하고자 한다. 실험에 사용된 Sample은 Si(100) p-type Wafer에 Boron을 이온 주입하여 제작하였다. 이온 주입 장비는 Varian E-500HP이며, 5.0E13 ions/cm2의 dose양을 80keV의 Energy로 각각 7도와 22도의 Tilt와 Twist Angle로 이온 주입을 하였다. SIMS분석에 사용된 Sample Holder는 각각 3 Hole, 9 Hole Type HOlder이며, 분석은 Cameca IMS-6f를 사용하여 B에 대한 Matrix Peak으로 28Si++를 얻었다. 실험 결과 3 Hole Type Sample Holder의 경우 RSF의 RSD는 5.84%, 9Hle Type Sample Holder의 경우는 14.3%로 나타났으나 분석 Window의 위치에 따르는 Grouping을 실시한 결과, 3 Hole Type Sample Holder의 경우 1.2%, 9Hole Type Sample Holder의 경우 9.8%로 RSF의 변화가 감소하였다. 이러한 Deviation은 Sample Holder를 Mount시킬 때 세 개의 Screw를 이용하여 Immersion Lens와의 평형을 잡아주기 때문에 발생하며, 이 Munting을 정확히 해줌으로써 RSF의 변화를 줄일 수 있으나, 실제로 완벽한 Mounting이 불가능하기 때문에 RSF를 일정하게 하기 위해서는 Sample Holder so Window의 취치를 일정하게 설정한 후 분석을 실시해야 한다고 판단된다.

  • PDF

A Comparative Analysis of Edge Detection Methods in Magnetic Data

  • Jeon, Taehwan;Rim, Hyoungrea;Park, Yeong-Sue
    • Journal of the Korean earth science society
    • /
    • v.36 no.5
    • /
    • pp.437-446
    • /
    • 2015
  • Many edge detection methods, based on horizontal and vertical derivatives, have been introduced to provide us with intuitive information about the horizontal distribution of a subsurface anomalous body. Understanding the characteristics of each edge detection method is important for selecting an optimized method. In order to compare the characteristics of the individual methods, this study applied each method to synthetic magnetic data created using homogeneous prisms with different sizes, the numbers of bodies, and spacings between them. Seven edge detection methods were comprehensively and quantitatively analyzed: the total horizontal derivative (HD), the vertical derivative (VD), the 3D analytic signal (AS), the title derivative (TD), the theta map (TM), the horizontal derivative of tilt angle (HTD), and the normalized total horizontal derivative (NHD). HD and VD showed average good performance for a single-body model, but failed to detect multiple bodies. AS traced the edge for a single-body model comparatively well, but it was unable to detect an angulated corner and multiple bodies at the same time. TD and TM performed well in delineating the edges of shallower and larger bodies, but they showed relatively poor performance for deeper and smaller bodies. In contrast, they had a significant advantage in detecting the edges of multiple bodies. HTD showed poor performance in tracing close bodies since it was sensitive to an interference effect. NHD showed great performance under an appropriate window.