• 제목/요약/키워드: Angle of the arms

검색결과 86건 처리시간 0.02초

The Effects of Posture on Neck Flexion Angle While Using a Smartphone according to Duration

  • Lee, Sang-Yong;Lee, Dae-Hee;Han, Seul-Ki
    • 대한물리의학회지
    • /
    • 제11권3호
    • /
    • pp.35-39
    • /
    • 2016
  • PURPOSE: The purpose of this study was to examine changes in the neck flexion angle according to posture while using a smartphone and the duration of smartphone usage. METHODS: The subjects in this study were 16 healthy young students in their 20s. The subjects wore a cervical range of motion instrument. They were instructed to use a smartphone while standing, sitting on a chair, and sitting on the floor. In all postures, they could use the smartphone and use their arms freely while keeping their back connected to the wall or the back of the chair. When sitting on the floor, they assumed a cross-legged position. The neck flexion angle was measured at zero, three, six, and nine minutes for each posture. RESULTS: Neck flexion is affected by the posture while using a smartphone (p<.05). Neck flexion in the standing position is larger than that in the sitting on the floor position. Neck flexion was affected by smartphone usage duration (p<.05). In general, as usage time increases, the neck flexion angle increases as well. CONCLUSION: This study suggests that using smartphone in the standing position and for a short period of time is a method to reduce the neck flexion angle.

4절링크의 전달각에 기초한 충격흡수식 안전기구 (Shock-Absorbing Safety Mechanism Based on Transmission Angle of a 4-Bar Linkage)

  • 박정준;김병상;송재복
    • 대한기계학회논문집A
    • /
    • 제29권11호
    • /
    • pp.1534-1541
    • /
    • 2005
  • Unlike industrial manipulators, the manipulators mounted on service robots are interacting with humans in various aspects. Therefore, safety has been one of the most important design issues. Many compliant robot arms have been introduced for safety. It is known that passive compliance method has faster response and higher reliability than active ones. In this paper, a new safety mechanism based on passive compliance is proposed. Passive mechanical elements, specifically transmission angle of the 4-bar linkage, springs and shock absorbing modules are incorporated into this safety mechanism. This mechanism works only when the robot arm exerts contact force much more than the human pain tolerance. Validity of this mechanism is verified by simulations and experiments. It is shown that the manipulator using this mechanism provides higher performance and safety than those using other passive compliance mechanisms or active methods.

초점길이 및 왜곡수차 측정장치 제작 (Fabrication of the focal length and distortion measurement system)

  • 조현모
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.82-86
    • /
    • 1990
  • A camera type optical bench system equipped with a lens collimator and an image analyzer is fabricated to measure the equivalent focal length and distortion of lenses. This system is automatized by the computer which controls stepping motors. A nodal slide optical bench system equipped with an off axis reflective collimator is fabricated and improved by using rotating arms and air bearing system. distortion measurement on a wide angle lens using the camera method and the nodal slide method is reported. Defocusing error in the distortion measurement with the nodal slide optical bench is analyzed and improved by iteration method to search the correct image point.

  • PDF

계통선 연결형 인버터 시스템 구성에 관한 연구 (A PWM Controlled High Frequency Link Inverter for Utility Interface Application)

  • 조기연;유동욱;김은수;배진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.466-470
    • /
    • 1991
  • In this paper, full bridge inverter with IGBT is proposed. By Controlling phase angle difference between 2 arms, PWM controlled high frequency link inverter has VVVF capability. For the simplicity, flexibility and compactness of control circuit, 16 bit single chip microcontroller 8797 BH is used and its characteristic is examined through experiment.

  • PDF

스포츠에어로빅스 팔착지 동작의 연계관절 각도와 모멘트분석 (Analysis of connecting joint anglle and moment in arm landing action in Sports Aerobics)

  • 유실
    • 한국운동역학회지
    • /
    • 제13권3호
    • /
    • pp.311-325
    • /
    • 2003
  • A relation between the movement range of arms and arising moment has been studied to find out efficient movement range to minimize impact concerning arm landing in sports aerobics. Four male athletes who won top three in national-level sports aerobics competition were chosen for the experiment. They were allowed to jump in between two force platform so that the right hand and the right leg could land onto the front and rear force platform, respectively. The sampling frequency was 200 Hz. The main conclusions based on the analysis of the angle and joint moment parameters of wrist, elbow, and shoulder are as follows: 1. The wrist moment was small when its angle was small, indicating that the dorsi-flexion of the wrist joint offered a positive influence to reduce wrist moment. 2. The elbow angle increased as wrist angle decreased and vice versa. This means that the movement range of the wrist joint affects that of the elbow joint. The darsi-flexion of the wrist is the position to absorb the impact of the elbow effectively rather than to absorb the impact of the wrist itself. The impact is absorbed by the flexion of wrist joint rather than the wrist. 3. The degree of moment transfer of the shoulder joint, having absorbed the impact from the elbow and elbow joint, became dependent on the efficiency of the fore-joints impact absorption.

복굴절이 큰 광섬유에 제작된 장주기 광섬유 격자를 이용한 광섬유 전류 센서 (Fiber-optic Ccurrent Sensor Using a Long-period Fiber Grating Inscribed on a High Birefringent Fiber)

  • 이용욱
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1823-1825
    • /
    • 2007
  • Based on Faraday effect, the variation of current flowing through the conductor can be encoded as that of azimuth angle of light polarization propagating through the fiber coil wound onto the conductor. The amount of current can be obtained by measuring the variation of the light intensity transformed from that of the azimuth angle through a polarization analyzer. In this paper we propose a fiber-optic current sensor system that employs a fiber polarization analyzer as a sensor interrogation device. The fiber polarization analyzer was prepared by inscribing a long-period fiber grating on a high birefringent fiber. At the fixed wavelength of 1522.5 nm, the fabricated fiber device has the polarization extinction ratio of more than 25 dB. The measurement of large current up to 600 Arms was accomplished based on a simple fiber interrogation device and the measurement output of the sensor system showed a good linearity.

CCD PHOTOMETRY OF THE GALAXIES ESO598-G009, NGC1515 AND NGC7456

  • CHO YOUNG JUN;PARK BYEONG-GON;YOON TAE SEOG
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.79-80
    • /
    • 1996
  • We performed CCD surface photometry in B,V,R and I filters for three southern spiral galaxies:ESO598-G009,NGC1515 and NGC7456. Isophotal map, luminosity profile, ellipticity profile and position angle profile were obtained for these galaxies using SPIRAL package. The results show that one of the galaxies, ESO598-G009 has relatively large bulge component and changes in position angle due to spiral arms. The NGC7456 has very small bulges; and the isophotal map of the NGC1515 shows that it is a typical spiral galaxy with bar.

  • PDF

수직 다관절 사과수확로봇의 매니퓰레이터 개발 (I) -설계.제작- (Development of Manipulator for Vertically Moving Multi-Joint Apple Harvesting Robot(I) -Design.Manusacturing-)

  • 장익주
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.399-408
    • /
    • 2000
  • This study is final focused on developing fruit harvesting robot can distinguish fruit type and status accurately. Multi-joint robot is able to discriminate tree shape and select mature fruit by image processing. The multi-joint robot consists of (a) rotating base, (b)turning first joint-arm, (c)rotating and turning second joint-arm, (d)rotating and turning third joint-arm, (e)rotating and turning last joint and (f)picker hand. The operational ranges of the robot are: horizontal 860~2,220mm, vertical 1,440~2,260mm, 270 degrees’rotation angle, 90 or 270 degrees’turning angle. The robot weighs 330kg. The multi-joint robot was designed in high accuracy and efficiency by getting as close as the movements of human arms and waist.

  • PDF

정리정돈용 서비스 로봇 플랫폼의 구현 연구 (A Study on Implementation of Service Robot Platform for Mess-Cleanup)

  • 김승우;김하이준
    • 제어로봇시스템학회논문지
    • /
    • 제18권5호
    • /
    • pp.487-495
    • /
    • 2012
  • In this paper, a Smart Home Service Robot, McBot II, which performs mess-cleanup function etc. in house, is designed much more optimally than other service robots. It is newly developed in much more practical system than McBot I which we had developed two years ago. One characteristic attribute of mobile platforms equipped with a set of dependent wheels is their omni- directionality and the ability to realize complex translational and rotational trajectories for agile navigation in door. An accurate coordination of steering angle and spinning rate of each wheel is necessary for a consistent motion. This paper develops trajectory controller of 3-wheels omni-directional mobile robot using fuzzy azimuth estimator. A specialized anthropomorphic robot manipulator which can be attached to the housemaid robot McBot II, is developed in this paper. This built-in type manipulator consists of both arms with 4 DOF (Degree of Freedom) each and both hands with 3 DOF each. The robotic arm is optimally designed to satisfy both the minimum mechanical size and the maximum workspace. Minimum mass and length are required for the built-in cooperated-arms system. But that makes the workspace so small. This paper proposes optimal design method to overcome the problem by using neck joint to move the arms horizontally forward/backward and waist joint to move them vertically up/down. The robotic hand, which has two fingers and a thumb, is also optimally designed in task-based concept. Finally, the good performance of the developed McBot II is confirmed through live tests of the mess-cleanup task.

두 팔 달린 두 바퀴 형태의 모바일 역진자 시스템의 신경회로망 제어 (Neural Network Control of a Two Wheeled Mobile Inverted Pendulum System with Two Arms)

  • 노진석;김현욱;정슬
    • 한국지능시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.652-658
    • /
    • 2010
  • 본 논문에서는 밸런싱 메커니즘의 두 바퀴 형태의 이동로봇(Two Wheeled Mobile Robot:TWMR)을 구현하고 제어한다. TWMR은 역진자 시스템과 이동로봇을 합친 모바일 역진자 구조로 기존의 막대 형태의 진자대신 두 팔 달린 로봇 형태를 나타낸다. 각도와 위치에 대한 동시제어에 있어 외란에 대한 강건성을 부여하기 위해 RBF 신경회로망 제어 방식을 사용한다. 신경회로망 제어 방식으로는 입력보상 방식(RCT)을 사용하여 제어기의 성능을 실험을 통해 검증한다. 또한 원격으로 제어가능하게 하도록 시스템을 구현하여 실험하였다.