• Title/Summary/Keyword: Angle of elbow joint

Search Result 89, Processing Time 0.04 seconds

The Kinematic Analysis and the Study of Muscle Activities during Backhand Drive in Squash (스쿼시 백핸드 드라이브 동작 시 운동학적 분석과 근활성도에 관한 연구)

  • Cho, Kyu-Kwon;Kim, You-Sin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.11-21
    • /
    • 2007
  • The purpose of this study was to examine the differences of kinematics and muscle activities depending on the changes of angle approaching balls during backhand drive in squash. The results are as follows. Stride time took the longest at AD2 and step lengths were the biggest at AD1 of left foot contact and right foot contact and AD2 of impact and follow-through. The center of gravity and the speed of racket head were the highest at AD3 and at AD2. Angle of shoulder joint were the biggest at AD1 of left foot contact, right foot contact and impact and AD3 of follow-through. Angle of elbow joint were the biggest at AD3 of left foot contact, right foot contact and follow-through and AD2 of impact. Angle of pelvis joint were the biggest at AD2 of left foot contact, AD1 of right foot contact and AD3 of impact and follow-through. Angle of knee joint were the biggest at AD2 of left foot contact, AD1 of right foot contact and AD3 of impact and follow-through. Angle of ankle joint were the biggest at AD1 of left foot contact and AD3 of right foot contact, impact and follow-through. According to the analysis results of triceps brachii, latissimus dorsi, brachioradialis muscle and flexor carpi ulnaris muscle activities were high at AD1 of all phases. Analysis results of vastus lateralis, vastus medialis, tibialis anterior and gastrocnemius medial muscle activities were high at AD2 of phase1 and phase3. Those of vastus lateralis, vastus medialis and tibialis anterior, gastrocnemius medial were high at AD3 of Phase 2 and AD1 of phase2.

Biomechanical Analysis with the Force of Deltoid Muscle for Pianist

  • Shin, Dong-Ok;La, Seung-Houn
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.27-31
    • /
    • 2005
  • This study presents the relationship between the height of the chair and the force of deltoid muscle for pianist. The subject simulated playing the piano on the three different heights of the chairs. Digital camera was used to determine the angle of the joint of shoulder and elbow for 2-dimensional static link segment modeling in the sagittal plane. The deltoid, biceps and triceps muscles were considered to determine the muscle load. The results, compared to the force of deltoid muscle, are that the downward position of the higher chair produces significantly large force than the other two lower chairs. It can be caused by hunched shoulder with decreasing deltoid angle. In case of the upward position caused by the lower chair, even though the smallest force of deltoid presented, it was increased the force of elbow.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

A Kinematic Analysis of the National Elite Cross-Country Skiers' Double Poling Technique (국가대표 크로스컨트리 스키 선수들의 Double Poling 기술의 운동학적 분석)

  • Choi, Seul-Bi;Ryu, Jae-Kyun
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.259-268
    • /
    • 2011
  • This study aimed to examine the kinematic characteristics of the national elite cross-country skiers' double poling technique and to provide the quantitative data for better performance. Four male elite cross-country roller skiers skied maximum velocity with Double Pole technique. The cycle characteristics with angles of elbow, hip, and knee joint were analyzed. The results showed that CM velocity of the body was increased with the third cycle, the cycle time and length were also increased. The poling time and recovery time rate showed with 32.79%, 67.44% respectively. The joint angles with elbow, hip and knee were $106^{\circ}$, $133.14^{\circ}$ $156.87^{\circ}$ at pole in event, $158.94^{\circ}$, $65.7^{\circ}$, $140.19^{\circ}$ at pole out event. Elite skiers should decrease double poling time rate and increase recovery time rate in order to improve the double poling performance. The cycle length and velocity of the double poling should be increased for the better performance. The elbow angle should be minimized at pole in event with maximum extension until pole out event. The hip and knee angles should be increased for the recovery phase.

Comparison on Grip Strength according to Shoulder Joint Angle with Elbow Extension (주관절신전 상태에서 견관절 각도에 따른 파악력 비교)

  • Seo, Gyu-Weon;Baek, Seung-Hwa;Shin, Hong-Cheul
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.1
    • /
    • pp.915-921
    • /
    • 1999
  • The purpose of this study was to determine the effect of testing posture and shoulder position on grip strength. The subjects were one hundred volunteers of Shinsung College (50 males and 50 females), ages from 20 to 27 years(mean age of 22.1 years). This study was carried out from september 7 to setember 10, 1998. The data were analyzed by mean and deviation, unpaired t-test, paired t-test, one way ANOVA and correlation. These results were obtained as follows; 1. Comparison on grip strength by left and right hand, there was a significant difference in standing and sitting position (p<0.05). 2. Comparison on grip strength between male and female, there was a significant difference in standing and sitting position (p<0.05). 3. One-way ANOVA on grip strength according to shoulder joint angle, there was a no significant difference in standing and sitting position (p>0.05). 4. Correlation on grip strength by sitting verus standing, there was a very significantly difference (p<0.01).

  • PDF

Elbow Arthrodesis with bone Autograft for the Management of Gunshot Fracture in a Dog (총상 골절 개에서 자가골 이식과 주관절 고정술)

  • Lee Jong Il;Alam Md. Rafiqul;Kim Nam soo
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.60-64
    • /
    • 2005
  • A 6year-old intact male hound cross dog, weighing 23 kg, was presented to the Teaching Animal Hospital, Chonbuk National University with the history of gunshot wound at the left elbow joint. Survey radiographs of the affected elbow revealed the presence of a metallic bullet caudal to the olecranon processes and comminuted fracture of the proximal radius and ulna. The first treatment strategy included removal of the bullet and fixation of the radius and ulna using separate bone plates, bone screw, K-wire and surgical wire, was failed. The second treatment strategy included olecranon osteotomy and rigid immobilization of the elbow joint with a bone plate applied to the caudal aspect of the humerus and ulna along with autogenous bone grafts collected from the 13th rib. The optimal angle of the joint following arthrodesis of this case appeared to be 130°. This resulted in improving the case but after 60 weeks the plate was bent and there was exudation from the wound. The third treatment strategy was the same with the second except for that the bone autografts were collected from the proximal metaphyses of the ipsilateral humerus. This resulted in a successful arthrodesis 6 weeks after the surgery. Elbow arthrodesis with bone autograft resulted in acceptable function, but abnormal gait remained in the dog due to mechanical interference with the movement of the joint.

Prosthetic arm control using muscle signal (생체 근육 신호를 이용한 보철용 팔의 제어)

  • Yoo J.M.;Kim Y.T.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1944-1947
    • /
    • 2005
  • In this paper, the control of a prosthetic arm using the flex sensor signal is described. The flex sensors are attached to the biceps and triceps brchii muscle. The signals are passed a differential amplifier and noise filter. And then the signals are converted to digital data by PCI 6036E ADC. From the data, position and velocity of arm joint are obtained. Also motion of the forearm - flexion and extension, the pronation and supination are abstracted from the data by proposed algorithm. A two D.O.F arm with RC servo-motor is designed for experiment. The arm length is 200 mm, weight is 4.5 N. The rotation angle of elbow joint is $120^{\circ}$. Also the rotation angle of the wrist is $180^{\circ}$. Through the experiment, we verified the possibility of the prosthetic arm control using the flex sensor signal. We will try to improve the control accuracy of the prosthetic arm continuously.

  • PDF

Fabrication of Poly(Vinylidene Fluoride) Nanocomposite Fibers Containing Zinc Oxide Nanoparticles and Silver Nanowires and their Application in Textile Sensors for Motion Detection and Monitoring (산화아연(Zinc oxide) 나노입자와 은나노 와이어(Silver nanowire)를 함유한 Poly(vinylidene fluoride) 복합나노섬유 제조 및 동작 센서로의 적용 가능성 탐색)

  • Hyukjoo Yang;Seungsin Lee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.47 no.3
    • /
    • pp.577-592
    • /
    • 2023
  • In this study, nanofiber-based textile sensors were developed for motion detection and monitoring. Poly(vinylidene fluoride) (PVDF) nanofibers containing zinc oxide (ZnO) nanoparticles and silver nanowires (AgNW) were fabricated using electrospinning. PVDF was chosen as a piezoelectric polymer, zinc oxide as a piezoelectric ceramic, and AgNW as a metal to improve electric conductivity. The PVDF/ZnO/AgNW nanocomposite fibers were used to develop a textile sensor, which was then incorporated into an elbow band to develop a wearable smart band. Changes in the output voltage and peak-to-peak voltage (Vp-p) generated by the joint's flexion and extension were investigated using a dummy elbow. The β-phase crystallinity of pure PVDF nanofibers was 58% when analyzed using Fourier transform infrared spectroscopy; however, the β-phase crystallinity increased to 70% in PVDF nanofibers containing ZnO and to 78% in PVDF nanocomposite fibers containing both ZnO and AgNW. The textile sensor's output voltage values varied with joint-bending angle; upon increasing the joint angle from 45° to 90° to 150°, the Vp-p value increased from 0.321 Vp-p to 0.542 Vp-p to 0.660 Vp-p respectively. This suggests that the textile sensor can be used to detect and monitor body movements.

Clinical outcomes of bending versus non-bending of the plate hook in acromioclavicular joint dislocation

  • Joo, Min Su;Kwon, Hoi Young;Kim, Jeong Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.202-208
    • /
    • 2021
  • Background: We aimed to assess the effect of plate hook bending in treatment of acromioclavicular (AC) dislocation by analyzing clinical and radiological results according to the angle of the plate hook (APH). Methods: This was a retrospective, observational, case-control study including 76 patients with acute AC joint dislocation that were divided into two groups according to treatment with bent or unbent plate hook. The visual analog scale (VAS), the American Shoulder and Elbow Surgeons (ASES) shoulder score, and range of motion (ROM) were evaluated as clinical outcomes. Comparative coracoclavicular distance (CCD) was measured to evaluate radiological outcomes. Results: While the VAS and ASES of the bending group at 4 months after surgery were significantly higher (p=0.021 and p=0.019), the VAS and ASES of the bending group at other periods and ROM of the bending group showed no significant difference. The initial CCD decreased from 183.2%±25.4% to 114.3%±18.9% at the final follow-up in the bending group and decreased from 188.2%±34.4% to 119.1%±16.7% in the non-bending group, with no statistical difference (p=0.613). The changes between the initial and post-metal removal CCD were 60.2%±11.2% and 57.3%±10.4%, respectively, with no statistical difference (p=0.241). The non-bending group showed greater subacromial osteolysis (odds ratio, 3.87). Pearson's coefficients for the correlation between APH and VAS at 4 months after surgery and for that between APH and ASES at 4 months after surgery were 0.74 and -0.63 (p=0.027 and p=0.032), respectively. Conclusions: The APH was associated with improved postoperative pain and clinical outcomes before implant removal and with reduced complications; therefore, plate hook bending is more useful clinically during plate implantation.

The Kinematic Analysis of the Last Stride landing and Release Phase in the Women Javelin (여자 창던지기 도움닫기 최종 1보 착지와 릴리즈 국면의 운동학적 분석)

  • Hong, Soon-Mo;Lee, Young-Sun;Kim, Tea-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.1
    • /
    • pp.51-63
    • /
    • 2004
  • The purpose of this study was to investigate a three dimensional kinematic variables about the last stride and the release phase of the throwing technique for female javelin throwers. For the motion analysis, Six female javelin throwers were used as subjects. Three-dimensional coordinates were collected using the Kwon3D Motion Analysis Package Version 2.1 Program. Two S-VHS Video Cameras were used to record the locations and orientations of control object and the performances of the subjects at a frequency of 6.0 HZ. After the kinematic variables such as the time, the distance, the velocity, and the angle were analyzed about the last stride and release phase, the followings were achieved; 1. For the effectively javelin throwing, the subjects appeared to do long the approach time in the phasel of landing phase, and short the delivery time in release phase 2. In the release event, the other subjects except for subject A appeared to throwing in the lower condition than the height of themselves. This result showed to slow the projecion velocity. 3. For increase the projection vcelocity of the upper extremity joint in the release event, it appeared to do extend rather the shoulder angle than increase the extension of elbow joint. 4. The body of COG angle showed to gradually increase nearly at the vertical axis in the release event. But the front lean angle of trunk showed a small angle compare to increase of the body of COG angle. Therefore for the effectively momentum transmission of the whole body in the javelin, the front and back lean angle of trunk appeared to do fastly transfer the angle displacement in the arch posture or the crescent condition during the deliverly motion of the release phase.