• 제목/요약/키워드: Angle at

검색결과 9,023건 처리시간 0.029초

폴리이미드 표면에서의 네마틱 액정의 틸트 제어를 이용한 High Tilted OCB(HTOCB) 모드 (A Hight Tilted OCB(HTOCB) Mode using Control of Tilt Angle for Hematic Liquid Crystal on Polyimide Surface)

  • 황정연;정연학;서대식
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.635-640
    • /
    • 2005
  • In this paper, we have improved a novel high tilted optically compensated bend (OCB) (HTOCB) mode by using high tilt angle that was generated by the unique baking condition on the homeotropic alignment layer. The high tilt angle of liquid crystal (LC) was generated by new alignment process that tilt angle changed homeotropic state to homeogenous state using Hot-plate equipment; we obtained about $40\~50^{\circ}$ tilt angle with negative and positive dielectric anisotropy on the homeotropic polyimide (PI), and then LC tilt angle decreased as increasing baking temperature and time. At last, we obtained about $10^{\circ}$ with positive type NLC $({\Delta}n>0)$. Also, the LC tilt angle of positive type NLC $({\Delta}n>0)$ decreased as increasing rubbing strength at the same baking temperature and time. The novel LC operating mode (HTOCB) that used the high tilt angle by the new alignment method was improved. The response time of the novel HTOCB cell was faster than that of conventional OCB cell. We suggest that the developed the novel HTOCB cell using control of tilt angle on the homeotropic surface is a promising technique for the achievement of a fast response time and a high contrast ratio.

튜브 벤딩시 스프링백 보정각 추세선 도출에 관한 연구 (A Study on the Derivation of Springback Compensation Angle Trend Line in Tube Bending)

  • 이덕영;오성국;최보성
    • 소성∙가공
    • /
    • 제29권4호
    • /
    • pp.188-193
    • /
    • 2020
  • Piping work of large ships or offshore plants is often done in a narrow and confined space, requiring precise bending and safety. In order to realize an accurate bending angle, it is very important to predict and correct a deformation that may be caused by elasticity in the bending process, that is, an angular deviation due to springback. Therefore, by using CAE analysis to develop a correction angle model for springback based on multiple tube bending angles and using trend line data derived from this correction angle model, at bending the tube as the diameter of the base former and the tube outer diameter change, the springback compensation angle at any angle can be obtained. In this study, the bending mechanism was analyzed to increase the bending precision, and a correction angle model was developed and a trend line was derived in consideration of springback occurring in the bending process. In order to derive a more accurate and reliable trend line, a tube tensile test was performed, and the reliability of the corrected angle trend line was verified by comparing the bending angle measurement and analysis results with a 3D scanner.

3차원 축류형 터빈에서 입사각의 영향에 관한 실험적 연구 (An Experimental Study of Incidence Angel Effect on 3-D Axial Type Turbine)

  • 김동식;조수용
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1292-1301
    • /
    • 2002
  • An experimental study of turbine performance is conducted with various incidence angles on a rotating turbine rotor. 5 different incidence angles are applied from -17$^{\circ}$to 13$^{\circ}$with 7.5$^{\circ}$gaps. In order to precisely set up the incidence angles at the rotor inlet, 5 turbine discs are manufactured with the different fir tree section. Total-to-total efficiencies are obtained on the several off-design points with considering the exit total pressure, which is meas fred at 12 locations between the hub and casing using a pressure rake. The degree of reaction is 0.373 at the mean radius, and Reynolds number based on the rotor chord is 0.86$\times$10$^{5}$ at the turbine inlet on the design point experiment. The experiment on a single-stage turbine is conducted at the low-pressure and low-speed state, but it is sufficient to consider the blade loading effect due to the rotating apparatus even though the total pressure loss at the exit is increased proportionally to the turbine output power. The experimental results recommend 6$^{\circ}$as an optimum incidence angle on the turbine blade design. The total-to-total efficiency is steeply decreased when the incidence angle is over $\pm$9$^{\circ}$ from the optimum incidence angle. In the range of less than -10$^{\circ}$incidence angle, 7.5$^{\circ}$ reduction of incidence angle generates 15% decrease of total-to-total efficiency. This result is obtained on the same rotor blade by changing only the rotational speed to minimize the effect of profile and secondary flow loss in the passage. Experimental results show that the change rate of total-to-total efficiency according to the incidence angle change is unchanged although the turbine operates at the off-design condition.

자세변화가 자율신경계에 미치는 영향 (The Influence of Position Change on Autonomic Nervous System Function)

  • 김인배;김은경;강종호
    • 대한물리의학회지
    • /
    • 제9권1호
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

Using the Crab Nebula as Polarization Angle Calibrator for the Korean VLBI Network

  • Minchul Kam;Sascha Trippe;Do-Young Byun;Jongho Park;Sincheol Kang;Naeun Shin;Sang-Sung Lee;Taehyun Jung
    • 천문학회지
    • /
    • 제56권1호
    • /
    • pp.1-9
    • /
    • 2023
  • The Crab nebula is widely used as a polarization angle calibrator for single-dish radio observations because of its brightness, high degree of linear polarization, and well-known polarization angle over a wide frequency range. However, the Crab nebula cannot be directly used as a polarization angle calibrator for single-dish observations with the Korean VLBI Network (KVN), because the beam size of the telescopes is smaller than the size of the nebula. To determine the polarization angle of the Crab nebula as seen by KVN, we use 3C 286, a compact polarized extragalactic radio source whose polarization angle is well-known, as a reference target. We observed both the Crab nebula and 3C 286 with the KVN from 2017 to 2021 and find that the polarization angles at the total intensity peak of the Crab nebula (equatorial coordinates (J2000) R.A. = 05h34m32.3804s and Dec = 22°00'44.0982'') are 154.2° ± 0.3°, 151.0° ± 0.2°, 150.0° ± 1.0°, and 151.3° ± 1.1° at 22, 43, 86, and 94 GHz, respectively. We also find that the polarization angles at the pulsar position (RA = 05h34m31.971s and Dec = 22°00'52.06'') are 154.4° ±0.4°, 150.7° ±0.4°, and 149.0° ± 1.0° for the KVN at 22, 43, and 86 GHz. At 129 GHz, we suggest to use the values 149.0° ± 1.6° at the total intensity peak and 150.2° ± 2.0° at the pulsar position obtained with the Institute for Radio Astronomy in the Millimeter Range (IRAM) 30-meter Telescope. Based on our study, both positions within the Crab nebula can be used as polarization angle calibrators for the KVN single-dish observations.

스쿼시 백핸드 드라이브 동작시 상지 분절의 운동학적 변인 분석 (The Kinematic Analysis of the Upper Extremity during Backhand Stroke in Squash)

  • 안용환;류지선;류호영;소재무;임영태
    • 한국운동역학회지
    • /
    • 제17권2호
    • /
    • pp.145-156
    • /
    • 2007
  • The purposes of this study were to investigate kinematic parameters of racket head and upper extremities during squash back hand stroke and to provide quantitative data to the players. Five Korean elite male players were used as subjects in this study. To find out the swing motion of the players, the land-markers were attached to the segments of upper limb and 3-D motion analysis was performed. Orientation angles were also computed for angular movement of each segment. The results were as follows. 1) the average time of the back hand swing (downswing + follow-through) was 0.39s (0.24 s + 0.15 s). 2) for each event, the average racket velocity at impact was 11.17m/s and the velocity at the end of swing was 8.03m/s, which was the fastest swing speed after impact. Also, for each phase, 5.10m/s was found in down swing but 7.68m/s was found in follow-through. Racket swing speed was fastest after the impact but the swing speed was reduced in the follow-through phase. 3) in records of average of joints angle, shoulder angle was defined as the relative angle to the body. 1.04rad was found at end of back swing, 1.75rad at impact and it changes to 2.35 rad at the end of swing. Elbow angle was defined as the relative angle of forearm to upper arm. 1.73rad was found at top of backswing, 2.79rad at impact, and the angle was changed to 2.55rad at end of swing. Wrist angle was defined as the relative angle of hand to forearm. 2.48rad was found at top of backswing, 2.86rad at impact, and the angle changes to 1.96rad at end of swing. As a result, if the ball is to fly in the fastest speed, the body has to move in the order of trunk, shoulder, elbow and wrist (from proximal segment to distal segment). Thus, the flexibility of the wrist can be very important factor to increase ball speed as the last action of strong impact. In conclusion, the movement in order of the shoulder, elbow and the wrist decided the racket head speed and the standard deviations were increased as the motion was transferred from proximal to the distal segment due to the personal difference of swing arc. In particular, the use of wrist (snap) may change the output dramatically. Therefore, it was concluded that the flexible wrist movement in squash was very important factor to determine the direction and spin of the ball.

FES보행중의 피드백제어를 위한 관절 각도계측 시스템 개발 (Development of Joint Angle Measurement System for the Feedback Control in FES Locomotion)

  • 문기욱;김철승;김지원;이재호;권유리;강동원;강곤;김요한;엄광문
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.203-209
    • /
    • 2009
  • The purpose of this study is to develop a minimally constraint joint angle measurement system for the feedback control of FES (functional electrical stimulation) locomotion. Feedback control is desirable for the efficient FES locomotion, however, the simple on-off control schemes are mainly used in clinic because the currently available angle measurement systems are heavily constraint or cosmetically poor. We designed a new angle measurement system consisting of a magnet and magnetic sensors located below and above the ankle joint, respectively, in the rear side of ipsilateral leg. Two magnetic sensors are arranged so that the sensing axes are perpendicular each other. Multiple positions of sensors attachment on the shank part of the ankle joint model and also human ankle joint were selected and the accuracy of the measured angle at each position was investigated. The reference ankle joint angle was measured by potentiometer and motion capture system. The ankle joint angle was determined from the fitting curve of the reference angle and magnetic flux density relationship. The errors of the measured angle were calculated at each sensor position for the ankle range of motion (ROM) $-20{\sim}15$ degrees (dorsiflexion as positive) which covers the ankle ROM of both stroke patients and normal subjects during locomotion. The error was the smallest with the sensor at the position 1 which was the nearest position to the ankle joint. In case of human experiment, the RMS (root mean square) errors were $0.51{\pm}1.78(0.31{\sim}0.64)$ degrees and the maximum errors were $1.19{\pm}0.46(0.68{\sim}1.58)$ degrees. The proposed system is less constraint and cosmetically better than the existing angle measurement system because the wires are not needed.

Assessment of lower incisor alveolar bone width using cone-beam computed tomography images in skeletal Class III adults of different vertical patterns

  • Lee, Sanghee;Hwang, Soonshin;Jang, Woowon;Choi, Yoon Jeong;Chung, Chooryung J;Kim, Kyung-Ho
    • 대한치과교정학회지
    • /
    • 제48권6호
    • /
    • pp.349-356
    • /
    • 2018
  • Objective: This study was performed to investigate the alveolar bone of lower incisors in skeletal Class III adults of different vertical facial patterns and to compare it with that of Class I adults using cone-beam computed tomography (CBCT) images. Methods: CBCT images of 90 skeletal Class III and 29 Class I patients were evaluated. Class III subjects were divided by mandibular plane angle: high (SN-MP > $38.0^{\circ}$), normal ($30.0^{\circ}$ < SN-MP < $37.0^{\circ}$), and low (SN-MP < $28.0^{\circ}$) groups. Buccolingual alveolar bone thickness was measured using CBCT images of mandibular incisors at alveolar crest and 3, 6, and 9 mm apical levels. Linear mixed model, Bonferroni post-hoc test, and Pearson correlation analysis were used for statistical significance. Results: Buccolingual alveolar bone in Class III high, normal and low angle subjects was not significantly different at alveolar crest and 3 mm apical level while lingual bone was thicker at 6 and 9 mm apical levels than on buccal side. Class III high angle group had thinner alveolar bone at all levels except at buccal alveolar crest and 9 mm apical level on lingual side compared to the Class I group. Class III high angle group showed thinner alveolar bone than the Class III normal or low angle groups in most regions. Mandibular plane angle showed negative correlations with mandibular anterior alveolar bone thickness. Conclusions: Skeletal Class III subjects with high mandibular plane angles showed thinner mandibular alveolar bone in most areas compared to normal or low angle subjects. Mandibular plane angle was negatively correlated with buccolingual alveolar bone thickness.

A-line Skirt의 Marking 효율에 관한 연구 (A Study on the Marking Efficiency of A-line Skirt)

  • 어미경
    • 한국의상디자인학회지
    • /
    • 제8권1호
    • /
    • pp.69-79
    • /
    • 2006
  • The purpose of this study is to find the proper width of fabric which can bring high efficiency on productivity. We focus on the marking method by comparing and analyzing the marking efficiency of A-line skirt. This study employs 4 criteria to mark the A-line skirt, which are cutting method, angle, width, and direction, respectively. There can be 2 different cutting methods(fold pattern and add seam pattern at the front and back center line), and 2 different angles(warp angle and bias angle). Also, width of the fabric can be classified into 2 groups(110cm, 150cm), and marking direction can be grouped into 2(one direction marker and one direction per each size marker). These 4 criteria make 16($2^*2^*2^*2$) cases for this study. Main findings are follows. First, the skirt with folded at the center line had higher efficiency rate than the skirt with add seam at the center line. Second, the skirt with the 150cm width has higher efficiency rate than that of 110cm. Third, fixing the warp angle has higher efficiency rate than that of fixing the bias angle at the front and back center line. Finally, one direction per each size marker has much higher efficiency than the one direction marker.

  • PDF

단결정 Ni기 초내열합금 액상확산접합부 단결정화에 미치는 접합방위차의 영향 (Effect of Bonding Misfit on Single Crystallization of Transient Liquid Phase Bonded Joints of Ni Base Single Crystal Superalloy)

  • 김대업
    • Journal of Welding and Joining
    • /
    • 제20권5호
    • /
    • pp.93-98
    • /
    • 2002
  • The effect of bonding misfit on single crystallization of transient liquid phase (TLP) bonded joints of single crystal superalloy CMSX-2 was investigated using MBF-80 insert metal. The bonding misfit was defined by (100) twist angle (rotating angle) at bonded interface. TLP bonding of specimens was carried out at 1523K for 1.8ks in vacuum. The post-bond heat treatment consisted of the solution and sequential two step aging treatment was conducted in the Ar atmosphere. The crystallographic orientation analysis across the TLP bonded joints was conducted three dimensionally using the electron back scattering pattern (EBSP) method. EBSP analyses f3r the bonded and post bonded heat treated specimens were conducted. All bonded joints had misorientation centering around the bonded interface for as-bonded and post-bond heat treated specimens with rotating angle. The average misorientation angle between both solid phases in bonded interlayer was almost identical to the rotating angle at bonded interface. HRTEM observation revealed that the atom arrangement of both solid phases in bonded interlayer was quite different across the bonded interface. It followed that grain boundary was formed in bonded interface. It was confirmed that epitaxial growth of the solid phase occurred from the base metal substrates during TLP bonding and single crystallization could not be achieved in joints with rotating angle.