• Title/Summary/Keyword: Angle at

Search Result 9,023, Processing Time 0.037 seconds

Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine

  • Kim, Jun-Hak;Choi, Gyeong-Mi;Chang, In-Bok;Ahn, Sung-Ki;Song, Joon-Ho;Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.181-188
    • /
    • 2009
  • Objective : To evaluate the anatomical parameters that must be considered when performing thoracic transpedicular or extrapedicular screw fixation. Methods : We selected 958 vertebrae (1,916 pedicles) from 98 patients for analysis. Eight parameters were measured from CT scans : the transverse outer pedicular diameter, transverse inner pedicular diameter, length, angle, chord length of the pedicles and the transverse width, angle, and chord length of the pedicle-rib units. Results : The age of the patients ranged from 21 to 82 years (mean: 48.2 years) and there were 57 men and 41 women. The narrowest transverse outer pedicular diameter was at T5 (4.4 mm). The narrowest pedicle length was at T1 (15.9 mm). For pedicle angle, T1 was 31.6 degrees, which was the most convergent angle, and it showed the tendency of the lower the level, the lesser the convergent angle. The chord length showed a horizontal pattern with similar values at all levels. For the PRU width, T5 showed a similar pattern to the pedicle width at 13.4 mm. For the PRU angle, T1 was the largest angle at 46.2 degrees and the tendency was the lower the level. the narrower the angle. For chord length, T1 was the shortest at 46.9 mm and T8 was the longest at 60.1 mm. Conclusion : When transpedicular screw fixations carried out at the mid-thoracic level, special care must be taken because there is a high chance of danger of medial wall violation. In these circumstances, extrapedicular screw fixation may be considered as an alternative treatment.

전단동축형 분사기들의 미립화 특성에 대한 연구 (Study on Atomization Characteristics of Shear Coaxial Injectors)

  • 안종현;이근석;안규복
    • 한국분무공학회지
    • /
    • 제26권1호
    • /
    • pp.9-17
    • /
    • 2021
  • Six shear coaxial injectors with different recess length and taper angle were manufactured. Cold-flow tests on the injectors were performed at room temperature and pressure using water and air as simulants. By changing the water mass flow rate and air mass flow rate, spray images were taken under single-injection and bi-injection. Breakup length and spray angle were analyzed from instantaneous and averaged spray images using image processing techniques. For all the injectors, the breakup length generally decreased as the momentum flux ratio increased at the same gas mass flow rate. The injectors with 7.5° taper angle usually had the longest breakup length and the smallest spray angle. When the taper angle was 15° or more, it hardly affected breakup length and spray angle. The recess length did not influence breakup length but its effect on spray angle depended on the taper angle.

달리기 시 운동화 중저의 경도가 신발굴곡각도의 크기에 미치는 영향 (The Influence of Midsole Hardness of Running Shoes on Shoes Flex Angle during Running)

  • 목승한;곽창수;권오복
    • 한국운동역학회지
    • /
    • 제14권2호
    • /
    • pp.85-103
    • /
    • 2004
  • This study was conducted to determine what effects would the midsole hardness of running shoes have on shoe flex angle and maximum propulsive force. Furthermore, the relationship between the shoes flex angle and maximum propulsive force was elucidated in order to provide basic data for developing running shoes to improve sports performances and prevent injuries. The subjects employed in the study were 10 college students majoring in physical education who did not have lower limbs injuries for the last one year and whose running pattern was rearfoot strike pattern of normal foot. The shoes used in this study had 3different hardness, shore A 40(soft), 50(medium) and 60(hard). The subjects were asked to run at a speed of $4{\pm}0.08m/sec$, and their movements were videotaped with 2 S-VHS video-cameras and measured with a force platform. And the following results were obtained after analyzing and comparing the variables. 1. Although the minimum angle of shoes flex angle was estimated to appear at SFA4, it appeared at SFA2 except in those shoes with the hardness of 40. 2. The minimum angle of shoes flex angle was $145.1^{\circ}$ with barefoot. Among the shoes with different hardness, it was the smallest when the hardness was 50 at $149.9^{\circ}$. The time to the minimum angle was 70.7% of the total ground contact time. 3. Maximum propulsive force according to midsole hardness was the largest when the hardness was 50 at $1913.9{\pm}184.3N$. There was a low correlation between maximum propulsive force and shoes flex angle.

20대 정상성인의 대퇴사두근각(Q angle)에 영향을 미치는 요인 (Factors Related to Q Angle in Healthy Adults)

  • 권혁철
    • 한국전문물리치료학회지
    • /
    • 제6권1호
    • /
    • pp.1-14
    • /
    • 1999
  • The quadriceps angle (Q angle) has been used to reflect the quadriceps muscle's force on the patella in the frontal plane. Previous investigations of the Q angle and it's relationship to knee disorders have yield equivocal results. The purpose of this study was to analyze the factors related to the Q angle and it's relation to other variables such as leg length, body weight, CTA (calcaneus to tibia angle), TOA (toe out angle), and pelvic width in normal subjects. The participants were 60 students (30 men and 30 women) who had no orthopedic and neurological impairments, aged from 20 to 29 years of age, with an average age of 22.1 years. Prior to participation, each subject was informed of the procedures of the experiment from a researcher and assistant researchers. The equipment used in this study were modified standard goniometer, ruler, marking pen, and Martin apparatus for pelvic width. In order to determine the statistical significance of the experiment, regression analysis, independent t-test, and Pearson correlation were used at the 0.05 level. The results were as follows: 1) It was found that the Q angle of women is greater than that of men's from both knees. 2) There was no significant difference between right and left quadriceps angle. 3) The Q angle decreased as the body weight (leg length) shifted from low to high. 4) It seems that factors related to the Q angle were body weight, CTA, and pelvic width, but there was no significant difference at the 0.05 level.

  • PDF

Study of Chromium thin films deposited by DC magnetron sputtering under glancing angle deposition at low working pressure

  • Bae, Kwang-Jin;Ju, Jae-Hoon;Cho, Young-Rae
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.181.2-181.2
    • /
    • 2015
  • Sputtering is one of the most popular physical deposition methods due to their versatility and reproducibility. Synthesis of Cr thin films by DC magnetron sputtering using glancing angle deposition (GLAD) has been reported. Chromium thin films have been prepared at two different working pressure($2.0{\times}10-2$, 30, $3.3{\times}10-3torr$) on Si-wafer substrate using magnetron sputtering with glancing angle deposition (GLAD) technique. The thickness of Cr thin films on the substrate was adjusted about 1 mm. The electrical property was measured by four-point probe method. For the measurement of density in the films, an X-ray reflectivity (XRR) was carried out. The sheet resistance and column angle increased with the increase of glancing angle. However, nanohardness and density of Cr thin films decreased as the glancing angle increased. The measured density for the Cr thin films decreased from 6.1 to 3.8 g/cc as the glancing angle increased from $0^{\circ}$ to $90^{\circ}$ degree. The low density of Cr thin films is resulted from the isolated columnar structure of samples. The evolution of the isolated columnar structure was enhanced at the conditions of low sputter pressure and high glancing angle. This GLAD technique can be potentially applied to the synthesis of thin films requiring porous and uniform coating such as thin film catalysts or gas sensors.

  • PDF

Kinematic Comparative Analysis of Short Turns between Skilled and Unskilled Alpine Skiers

  • Jo, Hyun Dai
    • 한국운동역학회지
    • /
    • 제29권4호
    • /
    • pp.219-226
    • /
    • 2019
  • Objective: The purpose of this study is to provide a better understanding of short turn mechanism by describing short turns after kinematic analysis and provide skiers and winter sports instructors with data through which they are able to analyze right postures for turns in skiing in a systematic, rational and scientific manner. Method: For this, a mean difference of kinematic variables (ski-hip angle, ski-shoulder twist angle, pole checking angle, the center of gravity (CG) displacement, trunk forward lean angle) was verified against a total of 12 skiers (skilled and unskilled, 6 persons each), regarding motions from the up-start to down-end points for short turns. Results: There was no difference in a ski-hip twist angle. The ski-shoulder twist angle was large at the up-start point while a pole-checking angle was high at the down-end point in skilled skiers. Concerning the horizontal displacement of CG, skilled skiers were positioned on the right side at the upstart point. No significant difference was observed in the trunk forward lean angle. Conclusion: According to the ski-shoulder twist angle and CG horizontal displacement results, the upper body should be kept leant toward the pole. In addition, big turns should be made via edging and angulation. During pole checking, the hand holding the pole should be thrown and released toward a vector direction of the forearm.

Does the Access Angle Change the Risk of Approach-Related Complications in Minimally Invasive Lateral Lumbar Interbody Fusion? An MRI Study

  • Huang, Chunneng;Xu, Zhengkuan;Li, Fangcai;Chen, Qixin
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권6호
    • /
    • pp.707-715
    • /
    • 2018
  • Objective : To investigate the potential risk of approach-related complications at different access angles in minimally invasive lateral lumbar interbody fusion. Methods : Eighty-six axial magnetic resonance images were obtained to analyze the risk of approach-related complications. The access corridor were simulated at different access angles and the potential risk of neurovascular structure injury was evaluated when the access corridor touching or overlapping the corresponding structures at each angle. Furthermore, the safe corridor length was measured when the corridor width was 18 and 22 mm. Results : When access angle was $0^{\circ}$, the potential risk of ipsilateral nerve roots injury was 54.7% at L4-L5. When access angle was $45^{\circ}$, the potential risk of abdominal aorta, contralateral nerve roots or central canal injury at L4-L5 was 79.1%, 74.4%, and 30.2%, respectively. The length of the 18 mm-wide access corridor was largest at $0^{\circ}$ and it could reach 44.5 mm at L3-L4 and 46.4 mm at L4-L5. While the length of the 22 mm-wide access corridor was 42.3 mm at L3-L4 and 44.1 mm at L4-L5 at $0^{\circ}$. Conclusion : Changes in the access angle would not only affect the ipsilateral neurovascular structures, but also might adversely influence the contralateral neural elements. It should be also noted to surgeons that alteration of the access angle changed the corridor length.

고영각 NACA 0021 익형 주위의 비정상 유동장에 대한 수치해석적 연구 (A Numerical Study on Unsteady Flowfield around a NACA 0021 Airfoil at High Angles of Attack)

  • 김상덕
    • 한국항공운항학회지
    • /
    • 제28권2호
    • /
    • pp.12-17
    • /
    • 2020
  • Even though the benefit of flight at high angle-of-attack is to be able to reduce the speed of flight and maneuvers in complex flight environment, the flight at high angle-of-attack, however, is easy to be in stall which is characterized by sever unsteady flow separation over an airfoil. Current unsteady numerical analysis using DES was conducted to predict the aerodynamic characteristics of a NACA 0021 airfoil at high angle-of-attack conditions. And this provides the comparison with the steady numerical one with the typical turbulence models. The unsteady calculation by DES is appropriate in terms of predicting the aerodynamic performance of NACA 0021 airfoil at high angle-of-attack conditions.

Abrasion Behaviors of NR/BR Compounds Using Laboratory Abrasion Tester

  • Son, Chae Eun;Yang, Seong Ryong;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • 제56권1호
    • /
    • pp.12-19
    • /
    • 2021
  • The abrasion behaviors of NR/BR blend vulcanizates were investigated using NR/BR = 100/0, 80/20, and 60/40 compounds. The abrasion test was performed using a laboratory abrasion tester (LAT) at slip angles of 1° and 7°. The size distributions of the wear particles and the abrasion rates were examined according to the rubber compositions and slip angles. The most abundant wear particles at the slip angle of 1° were sizes above 1,000 ㎛, irrespective of the rubber composition. The most abundant wear particles at 7° slip angle had sizes in the range of 212-500 ㎛, except for the NR = 100 sample. The wear particle size distribution shifted to a smaller size as the slip angle and BR content increased. The abrasion rate at 7° was much larger than that at 1° slip angle. Furthermore, the abrasion rate was notably increased by adding BR to NR.

Influence of Slip Angle on Abrasion Behavior of NR/BR Vulcanizates

  • Eunji Chae;Sung-Seen Choi
    • Elastomers and Composites
    • /
    • 제58권1호
    • /
    • pp.17-25
    • /
    • 2023
  • Abrasion tests of model tire tread compounds (NR and NR/BR blend compounds) were performed at different slip angles (1° and 7°) using a laboratory abrasion tester. The abrasion behavior was investigated by analyzing the worn surface and wear particles. The abrasion spacing formed on the specimen worn at the large slip angle of 7° was significantly narrower than that at the small slip angle of 1°, while the abrasion depth for the specimen worn at 7° was lower than that at 1°. The abrasion spacing and depth tended to be narrower and lower, respectively, as the BR content increased. The abrasion patterns were clearly visible on the outside of the specimen for the slip angle of 1° but not for 7°. The wear particles had a rough surface and there were numerous micro-bumps. It was found that the crosslink density affected the abrasion patterns and morphologies of the wear particles.