• Title/Summary/Keyword: Angle Measurement

Search Result 2,158, Processing Time 0.034 seconds

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta (위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정)

  • Kim, Moon Sun;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.142-148
    • /
    • 2016
  • To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.

A Study on Teaching Measurement in Grade 4 (측정영역의 지도에 관한 소고 - 4학년을 중심으로 -)

  • 이경화
    • Education of Primary School Mathematics
    • /
    • v.3 no.1
    • /
    • pp.55-62
    • /
    • 1999
  • Through our elementary school mathematics, measurement is a critical topic since measurement helps connect ideas within areas of mathematics and between mathematics and other disciplines. In grade 4, students should understand angle, time, perimeter and area of figures by active involving. The paper gives ten ideas about teaching these concepts.

  • PDF

Angle of view polarization characterization of LCDs

  • Boher, P.;Bignon, T.;Leroux, T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1615-1618
    • /
    • 2007
  • Performances of LCDs are generally evaluated in terms of luminance and color versus viewing angle. In the present paper we show that this type of display can be favorably characterized in terms of polarization. We show that ELDIM EZContrast instrument can be used to measure the degree of polarization the light and the ellipticity and polarization direction of the polarized component. This measurement is made versus incidence angle between 0 and $88{\circ}$ and for all the azimuth angles. Important differences between the displays can be detected and related to their internal structures when luminance and color profiles are quite similar.

  • PDF

Adjustable Pretilt Angle of Liquid Crystal Alignment Materials

  • Lin, Song-Shiang;Lee, Chein-Dhau;Su, Ya-Ting;Lee, Yu-Der
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.80-82
    • /
    • 2007
  • We have developed a series of fluorinated dimethacrylate copolymers. Our work has covered the synthesized derivatives of alignment materials, characterized the pretilt angle and uniformity of liquid crystal alignment layer. The pretilt angle can be tailored by using the fluorinated copolymer. Excellent uniformity was achieved as shown in experimental results.

  • PDF

Evaluation of the Accuracy of Grounding Impedance Measurement of Grounding Grid (접지그리드의 접지임피던스 측정의 정확도 평가)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Jeong, Dong-Cheol;Kim, Dong-Seong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.146-153
    • /
    • 2009
  • Recently, the common grounding systems are adapted in most large structures. Since the ground resistance is insufficient to evaluate the performance of grounding systems, it is needed to measure grounding impedance. Even though the methods of measuring grounding impedance of large grounding systems are presented in IEEE standard 81.2, but they have not been described in detail. In this paper, we present the accurate method of measuring grounding impedance based on the revised fall-of-potential method and measurement errors due to earth mutual resistance and ac mutual coupling depending on locating test electrodes at remote earth were examined for the 15[m]$\times$15[m] grounding grid. As a result, the measurement error due to earth mutual resistance is decreased when the distance to auxiliary electrodes increased. To get rid of measurement errors due to mutual coupling, the potential lead should be installed at a right angle to the current lead. When the angle between the potential and the current leads is an acute angle or an obtuse angle, the mutual couple voltage is positive or negative, respectively. Generally, the measurement errors due to mutual coupling with an obtuse angle route are lower than those with an acute angle route.

Effect of Step Width and TOA on Q-Angle and CTA in Walking (보행에 있어서 보격과 발목각도가 종경골각 및 대퇴사두근각에 미치는 영향)

  • Hwangbo Gak;Lee Jin-Hee;Chung Hyung-Kuk;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.8 no.1
    • /
    • pp.33-47
    • /
    • 1996
  • This study was performed to examine the correlation between calcaneus to tibia angle and Q-angle, and the effects of step width and toe out angle on the calcaneus to tibia angle and Q-angle. The age of participated subjects was from 19 to 29 years(Mean=22.95, SD=2.23) who have no significant orthopedic and neurological dysfunction. The marking tapes for measurement of Q-angle and calcaneus to tibia angle were placed on seven location of each subject. Video data were collected while the subject walked on a walking grid. The result as follows : 1. There were significant differences in the step width, toe out angle, and Q-angle but not calcaneus to tibia angle between male and female. 2. There were significant differences in toe calcaneus to tibia angle and Q-angle n step width increased, respectively. 3. There were significant differences between tee out angle and calcaneus to tibia angle but not toe out angle and q-angle. 4. There was statistically significant correlation between calcaneus to tibia angle and Q-angle.

  • PDF

Defects Length Measurement using an Estimation Algorithm of the Camera Orientation and an Inclination Angle of a Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup;Kang, E-Sok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1452-1457
    • /
    • 2004
  • In this paper, a method of measuring the length of defects on the wall and restructuring the defect image is proposed based on the estimation algorithm of a camera orientation which uses the declination angle of a laser slit beam. The estimation algorithm of the horizontally inclined angle of CCD camera adopts a 3-dimensional coordinate transformation of the image plane where both the laser beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect can be reconstructed to an image normal to the wall. From the result of a series of experiments, the measuring accuracy of the defect is measured within 0.5% error bound of real defect size under 30 degree of the horizontally inclined angle. The proposed algorithm provides the method of reconstructing the image taken at any arbitrary horizontally inclined angle to the image normal to the wall and thus, it enables the accurate measurement of the defect lengths only by using a single camera and a laser slit beam.

  • PDF

Correlation of the 3D-Surface Topography and Cobb's Angle in Scoliotic Patient's (측만증 환자에서 3차원 체표면 영상분석과 Cobb 각의 상관관계)

  • Choi, Eun-Jung;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.61-70
    • /
    • 2005
  • The purpose of study correlation between 3D-surface topography and Cobb angle in scoliotic patients. It would be recognizing possibility of clinical application with 3D-surface topography with scoliosis assessment and correlation analysis of obtained Cobb angle through measured results of surface topography and took X-ray of subjects with scoliosis, which used to 3D-surface topography of laser scan method. A scoliosis subjects 16(males 4, females 12) agreed for study's purport volunteer our study that diagnose the scoliosis through 3D-surface topography and X-ray. The results were as follow: It was shown that the relation of Cobb angle of scoliosis and itemized 3D-surface topography measurement in horizontal view(p<0.01). top difference of cervicothoracic and lumbar in anterior-posterior view(p<0.05), the top difference of thoracic, thoracolumbar(p<0.01). These results suggest that an itemized 3D-surface topography measurement was highly correlated with Cobb angle. It would be a useful diagnosis method and assessment of physical therapy plan.

  • PDF

The Directivity Measurement of Angle Probe by Photoelastic Visualization Method (광탄성가시화법에 의한 사각탐촉자의 지향성 평가에 관한 연구)

  • Nam, Y.H.;Date, K.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.83-89
    • /
    • 1994
  • It is important for an ultrasonic testing to know the sound pressure field and the directivity of ultrasonic waves propagating in a solid. The directivity of ultrasonic wave is closely related to the sensitivity, the scanning pitch, the arrangement of angle probe, and the defect kind in ultrasonic testing. This paper describes on the directivity measurement of ultrasonic wave using ultrasonic wave visualization method. The directivity of the shear wave emitted from the angle probes were constant during propagation. The difference of directivity was existed between 2MHz and 4MHz angle probes. The centers of directivity were located backward from the incident poing and inside of the angle probe and were not changed during the wave propagation.

  • PDF

Effects of Strake Incidence-Angle on the Vortex Flow of a Double-Delta Wing (스트레이크 붙임각이 이중 삼각날개의 와류에 미치는 영향)

  • 손명환;정형석;장조원
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.10
    • /
    • pp.7-15
    • /
    • 2006
  • The effects of strake incidence-angle on the vortex characteristics and the wing-surface pressure distribution for a double-delta wing with strake were investigated experimentally. The strake incidence-angle of negative sign(strake is pitched down from the main-wing upper-surface) increased the suction pressure of the wing-upper surface, which was the same effect of increase of angle of attack. This change of the suction pressure was caused by the closer movement of the vortex cores to the wing upper surface rather than the increase of the vortex strength.