• Title/Summary/Keyword: Angiostenosis

Search Result 3, Processing Time 0.022 seconds

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

Stent modeling and simulation of truss structure using SMA (형상기억합금 트러스 구조물을 이용한 스텐트의 설계 및 해석)

  • Yang, Seong-Pil;Kim, Sang-Haun;Cho, Mang-Hyo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.518-522
    • /
    • 2008
  • Recently, many patients related to heart disease have surgical operation by expanding a blood vessel to treat the angiostenosis. So far most angioplasties have been performed using balloon-dilative stent made of stainless steel. Some researchers are studying the stent made of shape memory alloy (SMA) to operate the angioplasty more easily. and there are several papers which introduce the angioplasty using SMA. However, most of the analysis models for stents are constructed using solid elements. So much computing time is required to solve the analysis model. In this study, we suggest the SMA stent model using 1D truss element which is much faster than stent model using 3D solid element. To represent non-linear behavior of SMA, we apply 1D SMA constitutive equation of Lagoudas'. Pseudo-elastic behavior of stent structures is presented as a numerical example.

  • PDF

The Research to Correct Overestimation in TOF-MRA for Severity of Cerebrovascular Stenosis (3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구)

  • Han, Yong Su;Kim, Ho Chul;Lee, Dong Young;Lee, Su Cheol;Ha, Seung Han;Kim, Min Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.180-188
    • /
    • 2014
  • It is very important accurate diagnosis and quick treatment in cerebrovascular disease, i.e. stenosis or occlusion that could be caused by risk factors such as poor dietary habits, insufficient exercise, and obesity. Time-of-flight magnetic resonance angiography (TOF-MRA), it is well known as diagnostic method without using contrast agent for cerebrovascular disease, is the most representative and reliable technique. Nevertheless, it still has measurement errors (also known as overestimation) for length of stenosis and area of occlusion in celebral infarction that is built by accumulation and rupture of plaques generated by hemodynamic turbulence. The purpose of this study is to show clinical trial feasibility for 3D-SPACE T2, which is improved by using signal attenuation effects of fluid velocity, in diagnosis of cerebrovascular disease. To model angiostenosis, strictures of different proportions (40%, 50%, 60%, and 70%) and virtual blood stream (normal saline) of different velocities (0.19 ml/sec, 1.5 ml/sec, 2.1 ml/sec, and 2.6 ml/sec) by using dialysis were made. Cross-examinations were performed for 3D-SPACE T2 and TOF-MRA (16 times each). The accuracy of measurement for length of stenosis was compared in all experimental conditions. 3D-SPACE 2T has superiority in terms of accuracy for measurements of the length of stenosis, compared with TOF-MRA. Also, it is robust in fast blood stream and large stenosis than TOF-MRA. 3D-SPACE 2T will be promising technique to increase diagnosis accuracy in narrow complex lesions as like two cerebral small vessels with stenosis, created by hemodynamic turbulence.