• Title/Summary/Keyword: Anechoic Chamber

Search Result 248, Processing Time 0.028 seconds

On-Glass Vehicle Antennas Using a Multi-Loop Structure (다중 루프 형태의 차량용 글래스 안테나)

  • Ahn, Seung-Beom;Kay, Young-Chul;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.230-239
    • /
    • 2009
  • In this paper, we propose a novel on-glass antenna for FM radio reception in a recreation vehicle(RV). We use a multi-loop structure that takes advantage of a broad matching bandwidth and a high vertical radiation gain by efficiently utilizing a given space of a quarter glass in spite of the simple planar structure. Transparency of the antenna is also improved by adjusting the stripline widths based on the induced current distributions. The proposed antenna is printed on a quarter glass of a commercial vehicle and antenna performances such as the return loss and the gain are measured in a semi-anechoic chamber. The result shows the average gain of -9.67 dBi along the bore-sight direction($\theta=90^{\circ}$, $\phi=270^{\circ}$) in the FM radio band(80$\sim$l10 MHz), which is higher than a commercial monopole typed on-glass antenna($G_{ave}$=-12.49 dBi) and micro-antenna($G_{ave}$=-19.24 dBi) mounted on the roof of the RV.

A Real-Time RPWM Inverter for Reduction of Switching Frequency Band Noise in the Induction Motor (유도전동기의 스위칭 주파수대 소음 저감을 위한 실시간 RPWM 인버터)

  • 나석환;최창률;양승학;김광헌;임영철;박종건
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.64-73
    • /
    • 1997
  • RPWM(Random Pulse Width Modulation) techniques have been attracting an interest as an excellent reduction method of acoustic noise on the inverter drive system. Using randomly changed switching fre-quency of the inverter, the power spectrum of the electromagnetic acoustic noise can be spread out into the wide-band area. The wide band noise is much more comfortable and less annoying than the narrow-band one. This paper describes an implementationof the triangular carrier frequency modultde RPWM inverter drive system The poweer soedtrum of the noise emittde from the induction motro was measured in the anechoic chamber. The analysis of the sources for the acoustic noise and the effects of the noise reduction are confirmed by the ceasured dpectra of the noise. Real-time RPWM along with the speed control was achieved by high speed DSP(Digital Signal Processor ) TmS320C31, By changing the center frequency and the bandwidth of the carrier, theis real-time RPWM scheme can be used as an efficient switching frequency band acoustic noise reduction method for the inverter system with variant load conditions.

  • PDF

The Radiation Compensation Method for Two Dimensional Direction Finding of GPS Signal and Experiment Method (광대역 GPS신호의 2차원 방향탐지를 위한 방사보정 기법 및 시험 방안)

  • Ju, Hyung-Jun;Park, Seul-Gi;Kim, Dong-Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.155-162
    • /
    • 2020
  • In this paper, we present a radiation compensation method and experiment method for two-dimensional direction finding by elevation and azimuth angles of broadband GPS signal, and then produce experimental results. Previous studies have performed direction finding by only using the azimuth angle of the detected signal. So, the compensation table utilizes compensation data by azimuth angles only. However, the presented method in this study has compensation data by azimuth and elevation angles for two-dimensional direction finding. Because of direction finding systems and applications are diversified, recently. So, we present a two-dimensional radiation compensation method. For evaluation of the presented compensation method, we calculate the ideal phase differences on the antenna for two-dimensional direction finding and simulate phase differences using a FEKO EM simulator. Subsequently, we analyze experimental data by radiation compensation experiments using the presented compensation method in an anechoic chamber.

Identification of Airborne-noise Source and Analysis for Noise Source Contribution of a GDI Engine Using Sound Intensity Method (음향 인텐시티법을 이용한 GDI 엔진 소음원 규명 및 소음 기여도 분석에 관한 연구)

  • Kim, Byung-Hyun;Lee, Sang-Kwon;Yoon, Joon-Seok;Shin, Ki-Chul;Lee, Sang-Jik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.985-993
    • /
    • 2012
  • In this paper, a new method is proposed to estimate the sound pressure generated from gasoline direct injection (GDI) engine. There are many noise sources as much as components in GDI engine. Among these components, fuel pump, fuel injector, fuel rail, pressure pump and intake/exhaust manifolds are major components generated from top of the engine. In order to estimate the contribution of these components to engine noise, the total sound pressure at the front of the engine is estimated by using airborne source quantification (ASQ) method. Airborne source quantification method requires the acoustic source volume velocity of each component. The volume velocity has been calculated by using the inverse method. The inverse method requires many tests and has ill-condition problem. This paper suggested a method to obtain volume velocity directly based on the direct measurement of sound intensity and particle velocity. The method is validated by using two known monopole sources installed at the anechoic chamber. Finally the proposed method is applied to the identification and contribution of noise sources caused by the GDI components of the test engine.

A Design of RFID Tag Antenna with High Sensitivity for Car Side Mirror (사이드 미러용 고감도 RFID 태그 안테나의 설계)

  • Han, Seung-Mok;Kim, Min-Seong;Min, Kyeong-Sik
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.793-798
    • /
    • 2008
  • This paper presents a design of RFID(Radio Frequency Identification} tag antenna which has high sensitivity for car side mirror. A proposed tag antenna ($154\;mm{\times}66\;mm{\times}1;mm$) resonants at 900 MHz and has a wide bandwidth of 690 MHz($490\;MHz{\sim}1180\;MHz$). The measured gain and readable range of tag antenna are 5.8 dBd and 10 m, respectively. Radiation pattern and readable range of proposed tag antenna located on inside of a side mirror including a car body are measured at anechoic chamber. It has been confirmed that the readable range in the vicinity of $90^{\circ}$ has been expanded about 1.5 m by comparison with one of proposed tag antenna without of car body. Good performance of the proposed tag antenna was observed and proved by comparison of measured results of commercial tag antenna.

Reduction of contraction and expansion noise of refrigerator using thermal deformation analysis (열변형 해석을 이용한 냉장고 수축팽창 소음저감)

  • Park, Seong-Kyu;Kim, Won-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.344-351
    • /
    • 2019
  • In this work, the mechanism of contraction and expansion noise generation is investigated, and effective methods are proposed to reduce the occurrence frequency of noise during operation of the refrigerator. First, the frequency spectrum analysis was made by using the sound pressure signal measured in an anechoic chamber to investigate the characteristic of noise and the frequency of occurrence. Second, a thermal deformation analysis was conducted to predict the location of noise source. It is found from the analysis that the biggest thermal deformation occurs in the middle of the left inner case in the freezer room. Following the investigation made, a noise reduction method is proposed. The method is proposed to reduce the contraction and expansion noise by reducing the thermal deformation through increasing ABS (Acrylonitrile Butadiene Styrene) thickness in the center of refrigerator.

Shielding Effectiveness Analysis of the Digital Module Storage Cabinet for Nuclear Power Plants According to the Internal Structure and the Angle of EM wave Incidence (내부구조와 전파 입사각에 따른 원전용 디지털 모듈 보관 캐비닛의 차폐효과 분석)

  • Youn, Sang-Woon;Jang, Do-Young;Choo, Ho-Sung;Kim, Young-Mi;Lee, Jun-Yong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • In this paper, the cabinet shielding effectiveness (SE) including digital modules for nuclear power plants is analyzed depending on the internal structure and electromagnetic (EM) wave incidence angle. To analyze the SE, the cabinet and modules are modeled using the FEKO EM simulation tool. The SE is then obtained by comparing the electric field with and without the cabinet. In addition, the cabinet SE is observed by changing various conditions such as the spacing of each digital module, incidence angle, and the polarization of the EM wave at the 2.4 G[Hz frequency. To verify the results, the dipole antenna for SE measurements is fabricated, and the SE is measured in a semi-anechoic chamber. The result demonstrates that the SE by the cabinet structure can be expected to be higher when the polarization of the incident EM wave is horizontal to the ground and the distance between the digital modules is wide.

Design and Verification of Far-field measurement system for W-band Millimeter-wave Antenna (밀리미터파(W대역) 안테나 측정을 위한 원-전계 측정 시스템 설계 및 검증)

  • Baek, Jong-Gyun;Hwang, In-June;Cho, Chi-Hyun;Joo, Joung-Myoung;Joo, Ji-Han;Park, Jong-Kuk;Kim, Jaesik;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.2
    • /
    • pp.43-50
    • /
    • 2022
  • In this paper, we designed and verified a Far-field measurement system for measuring the performance of an antenna operating in millimeter wave(W-band). For the antenna test, a measurement system should be selected according to the type of antenna, measurement items, measurement environment and period, etc. In the case of near-field measurement, it takes a lot of time because the number of measurement items increases when the antenna has multiple channels or various beams. Such an antenna can reduce the measurement time through Far-field measurement, and only necessary measurement items can be measured. Therefore, this study secured precise alignment of the far-field measurement system using a high-power laser and improved the measurement accuracy by applying a double amplifier system. The designed system was built in the anechoic chamber and verified by comparison with the verified Near-field measurement system.

Development of Comprehensive performance test equipment to confirm the performance of small radar systems (소형 추적 레이다 시스템 성능확인을 위한 종합성능시험 장비 개발)

  • Hong-Rak Kim;Youn-Jin Kim;Seong-Ho Park;Man Hee LEE;Da-Been LEE
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.139-147
    • /
    • 2023
  • The compact tracking radar system is a pulsed radar tracking system that searches, detects, and tracks targets in real time against aircraft targets with a small RCS(Radar Cross Section) maneuvering at high speed. This paper describes the development of comprehensive performance test equipment to verify the performance of the radar system in a anechoic chamber environment. Describes the design and manufacture of comprehensive performance test equipment to meet requirements, including the generation of simulated target signals to simulate aircraft target signals to verify performance in the laboratory environment of radar systems. It also describes a GUI(Graphic User Interface) program to check performance through a test in conjunction with the tracking radar system. Verify the comprehensive performance test equipment implemented through the performance test.

The Application of Fiber-Reinforced Composites to Electromagnetic Wave Shielding Enclosures (섬유강화 복합재료의 전자파 차폐 기구물에 대한 적용에 관한 연구)

  • Park Ki-Yeon;Lee Sang-Eui;Lee Won-Jun;Kim Chun-Gon;Han Jae-Hung
    • Composites Research
    • /
    • v.19 no.3
    • /
    • pp.1-6
    • /
    • 2006
  • As the structures of the high performance electronic equipments and devices recently become more complex, the electromagnetic interference (EMI) and compatibility (EMC) have been very essential for commercial and military purposes. Thus, sensitive electrical devices and densely packed systems need to be protected from electromagnetic wave. In this research, glass fabric/epoxy composites containing conductive multi-walled carbon nanotube (MWNT) and carbon fiber/epoxy composites as electrical shielding materials were fabricated and electrical properties of the composites were measured. The concerning frequency band is from 300 MHz to 1 GHz. The performances of composite shielding enclosures were predicted using electromagnetic wave 3-D simulation tool, CST Microwave Studio. The shielding enclosure made of carbon fiber/epoxy composites were fabricated and the shielding effectiveness (SE) was measured in the anechoic chamber.