• Title/Summary/Keyword: Anchor force

Search Result 212, Processing Time 0.027 seconds

Prediction of load transfer depth for cost-effective design of ground anchors using FBG sensors embedded tendon and numerical analysis

  • Do, Tan Manh;Kim, Young-Sang
    • Geomechanics and Engineering
    • /
    • v.10 no.6
    • /
    • pp.737-755
    • /
    • 2016
  • The load transfer depth of a ground anchor is the minimum length required to transfer the initial prestressing to the grout column through the bonded part. A thorough understanding of the mechanism of load transfer as well as accurate prediction of the load transfer depth are essential for designing an anchorage that has an adequate factor of safety and satisfies implicit economic criteria. In the current research, experimental and numerical studies were conducted to investigate the load transfer mechanism of ground anchors based on a series of laboratory and field load tests. Optical FBG sensors embedded in the central king cable of a seven-wire strand were successfully employed to monitor the changes in tensile force and its distribution along the tendons. Moreover, results from laboratory and in-situ pullout tests were compared with those from equivalent case studies simulated using the finite difference method in the FLAC 3D program. All the results obtained from the two proposed methods were remarkably consistent with respect to the load increments. They were similar not only in trend but also in magnitude and showed more consistency at higher pullout loading stages, especially the final loading stage. Furthermore, the estimated load transfer depth demonstrated a pronounced dependency on the surrounding ground condition, being shorter in hard ground conditions and longer in weaker ones. Finally, considering the safety factor and cost-effective design, the required bonded length of a ground anchor was formulated in terms of the load transfer depth.

A study on improvement of the lower canvas bar for reducing loss of stow net on anchor (안강망 어구의 유실 감소를 위한 하부 종대의 성능 개선 연구)

  • LEE, Gun-Ho;CHO, Sam-Kwang;KIM, In-Ok;CHA, Bong-Jin;JUNG, Seong-Jae;KOO, Myeong-Seong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.4
    • /
    • pp.271-278
    • /
    • 2018
  • In this study, the conventional cylinder-shaped lower bar on the canvas was modified and its performance was tested to improve the opening force of the stow net on anchor. The improved new lower bar used in the test is consisted of 13 flat bars with a length of 1.8 m, a width of 0.075 m and a thickness of 4 mm, and a pipe with a length of 2.0 m and a diameter of 50 mm. A stow net with the improved lower bar and a stow net with an existing lower bar were installed underwater and their trajectories for 21 hours were examined. To confirm their trajectories, GPS loggers were attached to the buoys on the left and right canvases and the buoy of the hauling rope. As a result of the test, the rotation of the gear with the improved bar was smoother than that with the existing bar. As a result of comparing the changes in the interval of the buoys attached to the canvas after the low and high tide, the buoy spacing of the gear with the improved bar is wider than that of the conventional gear; moreover, the larger the interval, the smoother the rotation of the fishing gear was. Therefore, it is considered that using the improved lower bar can enhance the performance of the stow net.

Minimum Wind Speed of Dragging Anchor for Ships in Jinhae Bay Typhoon Refuge (진해만 태풍 피항 선박의 주묘 한계 풍속에 관한 연구)

  • Kang, Byung-Sun;Jung, Chang-Hyun;Park, Young-Soo;Kong, Gil-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.4
    • /
    • pp.474-482
    • /
    • 2021
  • An average of two to three typhoons that occur in the Philippines or Taiwan pass through Korea each year owing to the influence of the geographical location and western winds. Because Jinhae Bay is known as Korea's representative typhoon refuge, it is filled with ships during typhoons and later becomes saturated with ships anchored to the surrounding routes. If a strong wind drags an anchored ship, a collision accident may occur because of the short distance between the ships. Therefore, a systematic anchoring safety management of Jinhae Bay is required. In this study, the minimum wind speeds of a dragging anchor based on the water depths of Jinhae Bay anchorages were investigated. When 7-9 shackles were given, the minimum wind speeds were 48-63, 46-61, and 39-54 knots at depths of 20, 35, and 50 m, respectively. As the water depth increased, the length of the cable laid on the sea bed became shorter than 5 m owing to the external force, and the minimum wind speed showed a significant difference of 4-8 knots. In addition, ships with high holding power anchors (AC-14 type) had higher minimum wind speeds than ships with conventional anchors (ASS type). Finally, it was confirmed that at a depth of 50 m, dragging easily occurred even when a high holding power anchor was applied.

The Deformation Behavior of Anchored Retention Walls installed in Cut Slope (절개사면에 설치된 앵커지지 합벽식 옹벽의 변형거동)

  • Yun, Jung-Mann;Song, Young-Suk
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.475-482
    • /
    • 2009
  • The behavior of earth retention wall installed in cut slope is different from the behavior of retention wall applied in urban excavation. In order to establish the design method of anchored retention walls in cut slope, the behavior of anchored retention wall can be investigated and checked in detail. In this study, the behavior of anchored retention wall was investigated by instrumentation installed in cut slope for an apartment construction stabilized by a row of piles. The horizontal displacement of anchored retention wall was larger than the displacement of slope soil behind the wall at the early stage of excavation. As the excavation depth became deeper, the horizontal displacement of slope soil was larger than the displacement of anchored retention wall. It means that the horizontal displacement of anchored retention wall due to excavation is restrained by soldier pile stiffness and jacking force of anchor. Jacking force of anchor was mainly influenced in the horizontal displacement of anchored retention wall. The displacements of anchored retention wall and slope soil were affected mainly by an rainfall infiltrated from the ground surface. Meanwhile, the horizontal displacement of anchored retention wall with slope backside was about 2-6 times larger than the displacement of anchored retention wall with horizontal backside of excavation.

The Deformation Behavior of Anchored Retention Walls in Cut Slope (절개사면에 설치된 앵커지지 흙막이벽의 변형거동)

  • Song Young-Suk;Lee Jae-Ho;Kim Tae-Hyung
    • The Journal of Engineering Geology
    • /
    • v.15 no.2 s.42
    • /
    • pp.155-168
    • /
    • 2005
  • The behavior of earth retention wall installed in a cut slope is different from the behavior of retention wall applied in an urban excavation. In order to establish the design method of anchored retention wall in the cut slope, the behavior of anchored retention wall needs to be investigated and checked in detail. In this study, the behavior of anchored retention wall was investigated by the instrumentation installed in the cut slope, where was stabilized by a row of piles in an apartment construction site. The horizontal displacement of anchored retention wall was larger than the displacement of slope soil behind the wall at the early stage of excavation. As the excavation depth became deeper, the horizontal displacement of slope soil was larger than the displacement of anchored retention wall. It means that the horizontal displacement of anchored retention wall due to excavation is restrained by soldier pile stiffness and jacking force of anchor at the early stage of excavation. lacking force of anchor was mainly influenced on the horizontal displacement of anchored retention wall. The displacements of anchored retention wall and slope soil were affected mainly by rainfall infiltrated from the ground surface. Meanwhile, the horizontal displacement of anchored retention wall with a sloped backside was about $2\~6$ times larger than the displacement of anchored retention wall with a horizontal backside of excavation.

A Scheme for Load Distribution and Macro Mobility in Hierarchical Mobile IPv6 (HMIPv6에서 부하분산 및 매크로 이동성 지원 방안)

  • Seo, Jae-Kwon;Lee, Kyung-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.4
    • /
    • pp.49-58
    • /
    • 2007
  • Hierarchical Mobile IPv6 (HMIPv6) has been proposed by Internet Engineering Task Force (IETF) to compensate for such problems as handover latency and signaling overhead in employing Mobile IPv6 (MIPv6). HMIPv6 supports micro-mobility within a domain and introduces a new entity, namely mobility anchor point (MAP) as a local home agent. However, HMIPv6 causes load concentration at a particular MAP and longer handover latency when inter-domain handover occurs. In order to solve such problems, this paper establishes a virtual domain (VD) of a higher layer MAP and proposes a MAP changing algorithm in which the routing path changes between mobile node (MN) and correspondent node(CN) according to the mobile position and the direction of the MN before inter-domain handover occurs. The proposed algorithm not only enables complete handover binding-update of the on-link care of address (LCoA) only when inter-domain handover occurs, but concentrated load of a particular MAP is distributed as well. This is because the MNs registered with higher layer MAP and lower layer MAP coexist in the VD. We simulate the performance of the proposed algorithm and compare with HMIPv6.

A Performance Enhancement Scheme of Hierarchical Mobility Management in IPv6 Networks (IPv6 네트워크에서 계층적 이동성 관리의 성능향상 방안)

  • Seo, Jae-Kwon;Lee, Kyug-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.10
    • /
    • pp.119-126
    • /
    • 2007
  • Recently, the mobility of users and mobile communication technologies have developed rapidly. The users in this state also want to connect their devices and to receive services anywhere, anytime. Hierarchical Mobile IPv6 (HMIPv6) has been proposed by the Internet Engineering Task Force (IETF) to compensate for such problems as handover latency and signaling overhead when employing Mobile IPv6 (MIPv6). HMIPv6 supports micro-mobility within a domain and introduces a new entity, namely Mobility Anchor Point (MAP) as a local home agent. However, HMIPv6 has been found to cause longer handover latency when the inter-domain handover occurs. This is because a Mobile Node (MN) has to generate two addresses and register them to Home Agent (HA) a MAP, respectively. In order to solve such problems, we propose a scheme that an MN generates one address and registers it to HA for supporting fast handover during the inter-domain handover process. In the proposed scheme, the load of MAP and MAP domain is reduced because the number of MNs which are managed by MAP is decreased and the MAP does not perform proxy Neighbor Discovery Protocol (NDP) to intercept packets destined to MNs. We evaluate the performance of proposed scheme in comparison to HMIPv6 through the simulation and numerical analysis.

Development of Stability Evaluation Algorithm for C.I.P. Retaining Walls During Excavation (가시설 벽체(C.I.P.)의 굴착중 안정성 평가 알고리즘 개발)

  • Lee, Dong-Gun;Yu, Jeong-Yeon;Choi, Ji-Yeol;Song, Ki-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.9
    • /
    • pp.13-24
    • /
    • 2023
  • To investigate the stability of temporary retaining walls during excavation, it is essential to develop reverse analysis technologies capable of precisely evaluating the properties of the ground and a learning model that can assess stability by analyzing real-time data. In this study, we targeted excavation sites where the C.I.P method was applied. We developed a Deep Neural Network (DNN) model capable of evaluating the stability of the retaining wall, and estimated the physical properties of the ground being excavated using a Differential Evolution Algorithm. We performed reverse analysis on a model composed of a two-layer ground for the applicability analysis of the Differential Evolution Algorithm. The results from this analysis allowed us to predict the properties of the ground, such as the elastic modulus, cohesion, and internal friction angle, with an accuracy of 97%. We analyzed 30,000 cases to construct the training data for the DNN model. We proposed stability evaluation grades for each assessment factor, including anchor axial force, uneven subsidence, wall displacement, and structural stability of the wall, and trained the data based on these factors. The application analysis of the trained DNN model showed that the model could predict the stability of the retaining wall with an average accuracy of over 94%, considering factors such as the axial force of the anchor, uneven subsidence, displacement of the wall, and structural stability of the wall.

The Study on Chip Surface Treatment for Embedded PCB (칩내장형 PCB 공정을 위한 칩 표면처리 공정에 관한 연구)

  • Jeon, Byung-Sub;Park, Se-Hoon;Kim, Young-Ho;Kim, Jun-Cheol;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.3
    • /
    • pp.77-82
    • /
    • 2012
  • In this paper, the research of IC embedded PCB process is carried out. For embedding chips into PCB, solder-balls on chips were etched out and ABF(Ajinomoto Build-ip Film), prepreg and Cu foil was laminated on that to fabricate 6 layer build-up board. The chip of which solder ball was removed was successfully interconnected with PCB by laser drilling and Cu plating. However, de-lamination phenomenon occurred between chip surface and ABF during reflow and thermal shock. To solve this problem, de-smear and plasma treatment was applied to PI(polyimide) passivation layer on chip surface to improve the surface roughness. The properties of chip surface(PI) was investigated in terms of AFM(Atomic Force Micrometer), SEM and XPS (X-ray Photoelectron Spectroscopy). As results, nano-size anchor was evenly formed on PI surface when plasma treatment was combined with de-smear(NaOH+KMnO4) process and it improved thermal shock reliability ($260^{\circ}C$-10sec solder floating).

An Experimental Study on Structural Capacity of Joint Between Composite PHC Wall Pile and Bottom Slab with CT Shear Connector (CT형강 전단연결재가 적용된 합성형 PHC벽체파일-하부슬래브 연결부 성능에 관한 실험적 연구)

  • Mha, Ho Seong;Won, Jeong Hun;Lee, Jong Ku
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.531-541
    • /
    • 2013
  • This paper investigated the structural capacity of the CT shear connectors, which is a kind of the perfobond rib and functions as an anchor transferring the tension force in the joint between a composite PHC wall pile and a bottom slab. The direct pull-out test was performed for various specimens. From failure modes and load-displacement curves, it was found that transverse rebars should be placed to holes in a web to restrict pull-out failure of CT shear connectors. The results of additional tests for specimens with transverse rebars and various support lengths indicated that all specimens were failed by the tension failure of PHC pile before pull-out failure of CT shear connector and concrete pull-out failure. Thus, the CT shear connector could endure the tension force between the PHC wall pile and the bottom slab.