연약지반상에 자켓팩앵커의 적용과 거동특성 (Behavior and Application of Jacket pack anchor in Soft ground)

  • 김태섭;조윤주;정창원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1065-1072
    • /
    • 2010
  • The excavation site in the new city of inchon songdo is distributed with soft reclaimed soil and marine deposit. So, the general ground anchor is not applied to this layer of soft ground as the earth retaining support system, because of settlement. And then, Jacket pack anchor which is newly developed in order to increasing the pullout resistance by certain grout bulb formation and expansion effect in soft ground is applied to this site instead of the general ground anchor. Though the maximum horizontal displacement shows about 30mm~100mm (The maximum horizontal displacement/excavation depth$\fallingdotseq$0.32~1.0%) according to excavation sequence, generally excavation work finished stably. Also, load cell after setting shows almost increasing trend with increasing horizontal displacement. It means that the settlement of Jacket pack anchor in soft ground is good. From the result of this case, we knew that Jacket pack anchor was able to use the earth retaining support system in soft ground. Using Jacket pack anchor in soft ground, The allowance of the horizontal displacement is applied more than general value considering soil factors.

  • PDF

콘크리트전주의 안정성에 미치는 근가의 영향 (Effects of Anchor Block on Stability of Concrete Electric Pole)

  • 안태봉
    • 한국지반환경공학회 논문집
    • /
    • 제13권11호
    • /
    • pp.5-10
    • /
    • 2012
  • 연약지반 내의 많은 콘크리트 전주가 외부의 힘에 의하여 파괴되어 왔다. 본 연구에서는 근가의 설치심도 및 근가의 개수를 변화시키면서 토압과 변위분석을 실시하여 근가가 콘크리트 전주의 안정성에 미치는 영향을 분석하였다. 근가의 깊이 3가지 중 1.5m 깊이에 설치하는 것이 적절한 것으로 보이며, 2.25m 깊이에 근가를 설치하면 과도한 굴착으로 인한 교란으로 변위가 크게 나타난다. 근가를 깊게 설치할수록 수동영역의 토압은 작아지고 주동토압은 커진다. 두 개의 근가를 설치하면 한 개의 근가를 설치할 때보다 전주의 상단의 변위는 43.8%, 지표에서는 55.6% 감소한다.

연약지반에서 CGP-앵커의 시공사례연구 (A Case Study on CGP Anchor of Open-Cuts in Soft Ground)

  • 천병식;양형칠;박신영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.621-628
    • /
    • 2002
  • Compaction Grouting Pack (CGP) Anchor which is composite anchor of bearing plus friction-type was chosen and executed for the open-cuts in soft ground. This paper presents an analysis of data from tests on composite-anchor by jacking force. The properties of composite-anchor was presented to be as follows , the maximum plastic displacement was 60 mm in abandoned coal fill deposit, the shear stress($\tau$) is expressed as $\tau$ = (equation omitted) kg/$\textrm{cm}^2$ in clayey silt.

  • PDF

현장실험에 의한 압축형 앵커의 인발거동특성 연구 (The Study on Pullout Resistance Characteristics of the Compression Anchor by Pullout Tests on the Field)

  • 홍석우
    • 한국해양공학회지
    • /
    • 제16권2호
    • /
    • pp.44-52
    • /
    • 2002
  • The mechanism of pullout resistance of compression anchor is analysed. This anchor is developed through the field pullout tests and the laboratory element test. The compression anchor is characterized by decrease of progressive failure, simple site work, economy and durability compared with tension anchor. The characteristics of compression anchor, compared with tension anchor. mainly are summarized as follows ; (1) The plastic displacement of anchor body is very small during pullout of anchor. (2) Total anchor length decreases by the shortening of free length; (3) The progressive failure is decreased.; (4) The safety factor for pullout resistance increases with time after construction of anchor.

Two Cases of Biodegradable Suture Anchor Displacement Diagnosed with Ultrasonography following Arthroscopic Rotator Cuff Repair

  • Oh, Joo Han;Song, Byung Wook;Rhie, Tae-Yon
    • Clinics in Shoulder and Elbow
    • /
    • 제18권4호
    • /
    • pp.254-260
    • /
    • 2015
  • With the advancement of shoulder arthroscopy, use of biodegradable suture anchors in the surgical repair of rotator cuff tears has increased. Because of the radiolucency of these anchors, radiography is not appropriate for early detection of anchor failure. Ultrasonography is an advantageous modality in visualizing biodegradable, radiolucent anchors on a real-time basis without risk of radiation exposure. We report on two cases of displacement of a biodegradable suture anchor diagnosed on ultrasonography during the postoperative follow- up, which has not been previously reported. Because this displacement could be missed in the postoperative follow up ultrasonography, we describe the ultrasonographic features of the displaced biodegradable anchors. Surgeons and radiologists should pay special attention to the possibility of displacement of the suture anchor in patients who underwent rotator cuff repairs using suture anchors.

폐탄매립층의 흙막이공사에서 CGP-앵커 시공사례연구 (Study on CGP-Anchor of Open-Cuts in Abandoned Coal Fill Deposit)

  • 천병식;양형칠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.416-423
    • /
    • 2001
  • The object of this study is to determine the application of friction and ground stress type CGP(Compaction Grouting Pack)-anchor in retaining wall construction on the soft ground by executing in the fill deposit with abandoned coal. In this study the effect of CGP-anchors as retaining wall anchor on the soft ground anchor was evaluated through measuring displacement according to tensile strength by acting tensile strength after equipping CGP-anchors. From the field tests results, CGP-anchor was determined to be considerably effective as retaining wall anchor on the soft ground by showing that the maximum displacement was 60mm and the elastic displacement was within 50mm by 53ton tensile strength.

  • PDF

기초근가와 기존근가의 하중에 따른 변위 비교분석 (A Comparative Analysis of Displacement Measurement of the Earth Surface by Load for Root Anchor Block and Rectangle Anchor Block)

  • 문성원;김점식;김도영;박용범
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.863-869
    • /
    • 2013
  • In this paper, we compared and analyzed for safety 1.2m rectangular anchor block and arch-type root anchor block. First, numerical analysis was performed three-dimensional nonlinear method by numerical model test using finite element analysis program "Visual FEA". Then, measure displacement of the surface of the earth after construct each anchor block at 14M electric pole and increase loads through field verification tests for safety evaluation.

사질토 지반에서 경사 인발 하중을 받는 석션 앵커의 회전 거동 평가 (Investigation of the Rotational Displacement of the Suction Anchor Subjected to the Inclined Pullout Load in Silty Sand)

  • 배준식;정영훈
    • 한국산학기술학회논문지
    • /
    • 제21권10호
    • /
    • pp.267-273
    • /
    • 2020
  • 석션 앵커는 비교적 간편한 설치 방식과 높은 안정성으로 인해 부유식 구조물을 고정하기 위한 기초로 사용된다. 최근, 허용 변위가 작은 부유식 구조물이 증가함에 따라, 석션 앵커의 유발 변위 평가에 대한 수요가 높아졌다. 하지만, 기존 석션 앵커의 연구는 앵커 지지력 평가에 초점을 두었으며, 앵커의 변위에 관한 연구는 중점적으로 수행되지 않았다. 특히, 경사진 하중을 받는 석션 앵커의 주된 변위인, 회전 거동을 평가한 연구는 매우 부족한 실정이다. 따라서 본 논문에서는 경사 인발 하중이 작용하는 석션 앵커의 회전 거동을 모형실험을 통해 비교 및 분석 하였다. 모형실험은 센트리퓨지 실험 장비를 사용하였으며, 실험 변수로는 하중의 경사도, 앵커의 크기 및 종횡비가 고려되었다. 하중-회전 변위 곡선을 산정하여, 실험 변수에 따른 석션 앵커의 회전량을 비교하였다. 실험 결과, 석션 앵커의 회전 거동은 하중의 경사도에 큰 영향을 받았으며, 앵커의 크기 및 종횡비에 따른 회전량의 차이는 크지 않았다.

모형실험 및 수치해석을 이용한 앵커형 네일의 적용성 검토 (Investigations of Application of Anchor Type Nail Using Experiments and Numerical Analysis)

  • 김동건;정길수;조광준;유남재;엄재경
    • 한국지반환경공학회 논문집
    • /
    • 제13권11호
    • /
    • pp.19-26
    • /
    • 2012
  • 본 논문에서는 지반 내 보강재를 삽입하여 원지반 전체의 전단강도와 활동저항력을 증가시켜주는 네일링에 프리스트레스를 가할 수 있는 PC강연선을 결합한 앵커형 네일에 대한 연구를 수행하였다. 앵커형 네일의 거동특성을 확인하기 위하여 무보강, 네일링, 앵커형 네일 각각에 대하여 실내모형실험과 수치해석을 수행하여 하중-변위, 벽체변위 등을 분석하였다. 실내모형실험결과 프리텐션을 가한 앵커형 네일의 경우 일반네일과 비교할 때 하중증가에 따른 수평변위량이 크게 감소되는 것이 확인되었으며, 특히 벽체상부의 변위 억제력이 커짐을 알 수 있었다. 이를 확인하기 위한 수치해석결과도 실내모형실험과 유사한 해석결과를 나타내었다.

연약지반에 시공된 전주의 실물인장실험을 통한 수평변위분석 (Horizontal Displacement Analysis of Electric Pole from Full Scale Pull-Out Test in Softground)

  • 안태봉
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.115-126
    • /
    • 2009
  • 연약지반상에 시공하는 수많은 전주가 태풍 등의 외부하중으로 전도파괴가 발생한다. 본 연구에서는 근가위치, 근가깊이, 근가개수, 전주근입깊이 등을 달리하며 연약지반에 실물크기의 전주에 인장실험을 실시하여 전주의 수평 변위분석을 실시하였다. 전주는 10개의 유형으로 나누어 실험한 결과 변위는 근가의 위치 및 수량, 전주기초의 근입깊이에 따라 뚜렷한 차이를 나타냈다. 초기하중 재하시 상부에서 굴절된 양상을 보이다 점증하중에 따라 전주의 중앙부로 굴절의 양상이 전이되었다. 근가위치는 G.L(-) 0.5[m]인 상태에서 전주기초 깊이 1.3[m]를 추가로 근입시 최대 수평변위는 약 1.6배의 감소를 보여 전주의 안정성이 증가하였다. 근가의 수는 근가 2개를 설치하는 것이 변위에 유리하나 큰 차이는 아니며 근가를 다수 설치하고 굴착면적이 커져 시공성이 떨어지는 단점이 있으므로 근가를 1개만 설치하여도 좋은 것으로 판단된다.