• Title/Summary/Keyword: Anatomic variation

Search Result 65, Processing Time 0.029 seconds

Asymmetry in mesial root number and morphology in mandibular second molars: a case report

  • Nayak, Gurudutt;Shetty, Shashit;Shekhar, Rhitu
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.45-50
    • /
    • 2014
  • Ambiguity in the root morphology of the mandibular second molars is quite common. The most common root canal configuration is 2 roots and 3 canals, nonetheless other possibilities may still exist. The presence of accessory roots is an interesting example of anatomic root variation. While the presence of radix entomolaris or radix paramolaris is regarded as a typical clinical finding of a three-rooted mandibular second permanent molar, the occurrence of an additional mesial root is rather uncommon and represents a possibility of deviation from the regular norms. This case report describes successful endodontic management of a three-rooted mandibular second molar presenting with an unusual accessory mesial root, which was identified with the aid of multiangled radiographs and cone-beam computed tomography imaging. This article also discusses the prevalence, etiology, morphological variations, clinical approach to diagnosis, and significance of supernumerary roots in contemporary clinical dentistry.

Common Hepatic Artery Originating from Left Gastric Artery: A Rare Variant Encountered in Gastric Cancer Surgery

  • Choi, Chang In;Jeon, Tae Yong
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.463-467
    • /
    • 2018
  • The hepatic artery can have numerous variations. However, a common hepatic artery originating from the left gastric artery and the entire hepatic blood supply furnished by the left gastric artery is an extremely rare anomaly. We encountered this anomaly in a patient with advanced gastric cancer. A surgeon should recognize this image appearance and identify the anomaly. Without knowledge of this anomaly and given the strategy for extensive lesser sac dissection generally employed during gastric cancer surgery, a surgeon could easily inadvertently divide this vessel, resulting in critical liver damage. We report a case of common hepatic artery originating from left gastric artery and review of the literatures.

Analysis of Set-up Errors during CT-scan, Simulation, and Treatment Process in Breast Cancer Patients (유방암 환자의 모의치료, CT 스캔 및 치료 과정에서 발생되는 준비 오차 분석)

  • Lee, Re-Na
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.169-175
    • /
    • 2005
  • Purpose: Although computed tomography (CT) simulators are commonly used in radiation therapy department, many Institution still use conventional CT for treatments. In this study the setup errors that occur during simulation, CT scan (diagnostic CT scanner), and treatment were evaluated for the twenty one breast cancer patients. Materials and Methods: Errors were determined by calculating the differences in isocenter location, SSD, CLD, and locations of surgical clips implanted during surgery. The anatomic structures on simulation film and DRR image were compared to determine the movement of isocenter between simulation and CT scan. The isocetner point determined from the radio-opaque wires placed on patient's surface during CT scan was moved to new position if there was anatomic mismatch between the two images Results: In 7/21 patients, anatomic structures on DRR Image were different from the simulation Image thus new isocenter points were placed for treatment planning. The standard deviations of the diagnostic CT setup errors relative to the simulator setup in lateral, longitudinal, and anterior-posterior directions were 2.3, 1.6, and 1.6 mm, respectively. The average variation and standard deviation of SSD from AP field were 1.9 mm and 2.3 mm and from tangential fields were 2.8 mm and 3.7 mm. The variation of the CLD for the 21 patients ranged from 0 to 6 mm between simulation and DRR and 0 to 5 mm between simulation and treatment. The group systematic errors analyzed based on clip locations were 1.7 mm in lateral direction, 2.1 mm in AP direction, and 1.7 mm in SI direction. Conclusion: These results represent that there was no significant differences when SSD, CLD, clips' locations and isocenter locations were considered. Therefore, it is concluded that when a diagnostic CT scanner is used to acquire an image, the set-up variation is acceptable compared to using CT simulator for the treatment of breast cancer. However, the patient has to be positioned with care during CT scan in order to reduce the setup error between simulation and CT scan.

CLINICAL STUDY ON KOREAN POSTERIOR MAXILLAE RELATED TO DENTAL IMPLANT TREATMENT (치과임플란트 치료와 관련된 상악구치부의 임상적 연구)

  • Lee, Du-Han;Lee, Seong-Hyun;Hwang, Ju-Hong;Lee, Jeong-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • Purpose of study: The purpose of this study was to provide adequate diagnostic guideline for the maxillary sinuses prior to dental implant treatment for edentulous posterior maxillary areas. For this purpose, our procedure involves the estimation of the remaining alveolar bone height, the examination of the anatomical variation in the maxillary sinuses (e.g. sinus septum), and the evaluation of the incidence of preoperative pathological conditions in the maxillary sinuses. Materials and Methods: We selected 189 patients to undergo computerized tomography (CT) in order to account for the posterior maxillary anatomy found in patients of Korean ethnicity. We evaluated the following using Dentascan software: Remaining alveolar bone height, incidence of sinus septum, and rate of preoperative pathologic conditions in the maxillary sinus. The average amount of remaining alveolar bone height was analyzed using the student's t-test for differences according to anatomical site, and the ANOVA was used for the differences according to age group with the level of significance set at 0.05. Results: Alveolar bone heights of upper first premolar, second premolar, first molar, and second molar was 12.24 mm, 10.37 mm, 7.16 mm, and 7.15 mm, respectively with statistical significance (P < 0.05). Incidence of sinus septum as an anatomic variation was 17 out of 189 cases (9.0%). Incidence of mucosal thickening as a pathologic variation was 82 out of 189 cases (43.4%). Conclusion: In treatment planning of posterior maxillary edentulous area of Koreans, the consideration of augmentation surgery for maxillary sinus is required in maxillary molar area before dental implant installation, and preoperative screening of the asymptomatic maxillary sinuses can be regarded as a reasonable preoperative procedure in the planning of dental implant treatment on the posterior maxillary edentulous area.

A STUDY OF THE ROOT SURFACE AREA, ANATOMIC STRUCTURE AND LINEAR VARIATION OF THE ROOT SURFACE AREA OF THE MANDIBULAR SECOND MOLAR (하악 제2대구치 치근의 형태학적 구조 및 표면적에 관한 연구)

  • Chung, Hyung-Geun;Kwon, Young-Hyuk;Lee, Man-Sup
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.159-169
    • /
    • 1993
  • The thirty six mandibular second molars, which were extracted because of hopeless tooth due to advanced periodontal disease, were measured the length of mesial and distal root and the distance from cementoenamel junction to root separation. The molars were cross-sectioned every 1.5 milimeter from cementoenamel junction to root apex perpendicular to long axis and each section was photographed, projected and measured with a calibrated Digital Curvi-Meter(Com Curvi-8. Japan). The root surface area (RSA), percentage of the RSA and the linear variation of the RSA were calibrated for each 1. 5 mm section. The results were as follows. 1. The mean length of the roots was 12. 98mm for mesial root, 11.84 mm for distal root. The mesial root was longer than distal root.(p<0.01) 2. The mean distance from the cementoenamel junction to the point at which the root separate from the root trunk was 3.82mm for the buccal furcation and 4.75mm for lingual furcation. The buccal root separation was coronal than the lingual root separation.(p<0.01) 3. The total root surface area was $317.78mm^2$. 4. The mean surface area of the root trunk was $150.06mm^2$ and averaged 42.54% of the total root surface area. 5. The mean root surface area was $88.79\;mm^2$ for the mesial root, $78.93mm^2$ for distal root, The mesial root surface area was wider than the distal root surface area.(p<0.05) 6. In comparision, the mean root trunk surface area of the mandibular 2nd molar was wider than that of mandibular 1st molar(p<0.01), but each root of 2nd molar was smaller than that of 1st molar(p<0.01).

  • PDF

Auto-segmentation of head and neck organs at risk in radiotherapy and its dependence on anatomic similarity

  • Ayyalusamy, Anantharaman;Vellaiyan, Subramani;Subramanian, Shanmuga;Ilamurugu, Arivarasan;Satpathy, Shyama;Nauman, Mohammed;Katta, Gowtham;Madineni, Aneesha
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.134-142
    • /
    • 2019
  • Purpose: The aim is to study the dependence of deformable based auto-segmentation of head and neck organs-at-risks (OAR) on anatomy matching for a single atlas based system and generate an acceptable set of contours. Methods: A sample of ten patients in neutral neck position and three atlas sets consisting of ten patients each in different head and neck positions were utilized to generate three scenarios representing poor, average and perfect anatomy matching respectively and auto-segmentation was carried out for each scenario. Brainstem, larynx, mandible, cervical oesophagus, oral cavity, pharyngeal muscles, parotids, spinal cord, and trachea were the structures selected for the study. Automatic and oncologist reference contours were compared using the dice similarity index (DSI), Hausdroff distance and variation in the centre of mass (COM). Results: The mean DSI scores for brainstem was good irrespective of the anatomy matching scenarios. The scores for mandible, oral cavity, larynx, parotids, spinal cord, and trachea were unacceptable with poor matching but improved with enhanced bony matching whereas cervical oesophagus and pharyngeal muscles had less than acceptable scores for even perfect matching scenario. HD value and variation in COM decreased with better matching for all the structures. Conclusion: Improved anatomy matching resulted in better segmentation. At least a similar setup can help generate an acceptable set of automatic contours in systems employing single atlas method. Automatic contours from average matching scenario were acceptable for most structures. Importance should be given to head and neck position during atlas generation for a single atlas based system.

Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography

  • Nascimento, Eduarda Helena Leandro do;Pontual, Maria Luiza dos Anjos;Pontual, Andrea dos Anjos;Perez, Danyel Elias da Cruz;Figueiroa, Jose Natal;Frazao, Marco Antonio Gomes;Ramos-Perez, Flavia Maria de Moraes
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.69-75
    • /
    • 2016
  • Purpose: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Results: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, $1.1{\pm}0.8mm$). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles.

Complete Rupture of the Extensor Hallucis Longus Tendon with Accessory Slip Mimicking a Partial Rupture: A Case Report (부분파열로 오인된 긴엄지발가락폄근의 주힘줄의 완전파열과 동반된 보조힘줄: 증례 보고)

  • Dong Hyeon Kim;Ji Hae Lee;Myeong Ja Jeong;Soung Hee Kim;Ji-Young Kim;Soo Hyun Kim;Mi-Jin Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.726-730
    • /
    • 2023
  • The accessory tendon of the extensor hallucis longus is a common type of extensor hallucis longus variation. This is a case of a 38-year-old female patient who initially considered conservative treatment for a suspected partial rupture, but finally underwent surgery after being diagnosed with a complete rupture of the main tendon and accessory tendon medial to the main tendon on MRI scan.

ASSESSMENT OF THE ANATOMIC VARIATION OF MANDIBULAR INCISIVE CANAL IN CHIN BONE HARVESTING (하악정중부에서 자가골 채취시 절치관의 해부학적인 변이에 대한 평가)

  • Kim, Ji-Hyuck;Kim, Se-Ho;Kwon, Kwang-Jun;Kim, Soung-Min;Park, Young-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.226-229
    • /
    • 2006
  • The interforaminal region is usually considered as a safe region in the chin bone graft without important vital anatomical structures to be damaged. But the accurate anatomy of the interforaminal region, with its potential clinical relationships, is controversial. Moreover some complications suggesting damage of incisive terminal branches after chin bone harvesting are reported such as sensory discomfort and pain etc. In order to verify incisive innervation of symphyseal area, we examined the cross-sectional CT scan images taken for preoperative planning of implant placement with chin bone graft and some parameters were measured; (1) visuality rating of incisive canal (2) vertical and horizontal diameter of canal (3) distance from lower border of the incisive canal to the lower border of the mandible (4) shortest distance from anterior border of the incisive canal to the anterior border of the mandible. We report the positive outcome that decrease the complications related with the damages of incisive branch during bone harvesting from the chin.

Three dimensional analysis of Korean dentogingival complex (한국인 치아치은 집합체구조의 삼차원적인 분석)

  • Park, Yeong-Suk;Lee, Seung-Pyo;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.199-206
    • /
    • 2008
  • Purpose: Variation in the morphology of gingival papilla may be determined by the shape and position of anatomic crown as well as contact area and embrasure form of individual teeth. However, periodontal biotype classification is regarded to be subjective because of the lack of definite criteria. In this study, we defined the objective parameters which constitute the periodontal biotype and measured their relationship. Materials and Methods: 109 of dental casts were prepared using three dimensional scanner and specialized reconstruction software, then acquiredvirtual models were sent to the 20 professional dentists to define the specific periodontal biotypes. Several parameters around periodontal structures were measured from the virtual models; facial surface area of the anterior tooth (AT), anterior papillary area (AP), proportion of the dento-papillary complex, clinical papillary length (PL), and clinical papillary angle (PA). Statistical analysis was performed to confirm the relationship among parameters. Results: Coincidence rate of periodontal biotype within observers was $63.77{\pm}16.05%$. Coincidence rate between observers was $76.15{\pm}16.43%$. Among the parameters measured, PL showed the most positive correlations and PA presented the most negative correlations. The parameter of the AP and PL of six maxillary anterior teeth showed significant correlation coefficient. Conclusion: Anterior papillary area and clinical papillary length would be objective parameters for determining the consistent periodontal biotypes.