• Title/Summary/Keyword: Anatomic study

Search Result 480, Processing Time 0.03 seconds

Assessment of Computed Tomographic Lung Density in Beagle and Shihtzu Dogs : Influence of Position and Positive End Expiratory Pressure (비글과 시츄견에서 호기말 양압에 따른 전산화 단층촬영상의 폐밀도의 평가)

  • Kim, Tae-Hun;Chang, Jin-Hwa;Yun, Seok-Ju;Yoon, Jung-Hee;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.273-283
    • /
    • 2010
  • The objective of this study was to measure densities in various areas of the normal canine lung with computed tomography (CT) depending on influences of gravity and the degree of lung inflation and to determine optimal positions and positive end expiratory pressure of canine lung for CT scanning. In each eight normal Beagle and Shihtzu dogs, a respiratory breathhold maneuver without spontaenous breathing at different positive end expiratory pressure (PEEP) of 0 mmHg, 10 mmHg and 20 mmHg was applied with the position of right and left lateral recumbency, sternal recumbency, and dorsal recumbency and spiral-CT scans of the total lung were acquired. Slices were selected at three levels through the apex, middle and basal lung at the aortic arch, carina and just above the diaphragm and lung density was measured in the dorsal, ventral, and lateral portions of the peripheral lung field. Lung density in dependent areas was higher than in nondependent areas (p < 0.05) regardless of species, positions, anatomic locations at the PEEP of 0 mmHg and 10 mmHg. However, no significant difference of lung density was found at PEEP of 20 mmHg in both species except the dorsal recumbency in Shihtzu dogs. This density gradient in the dependent areas is strongly influenced by PEEP (p < 0.05). In the four positions on the CT gantry, the lung density at the dependent and nondependent location of the lung was greater at the aortic arch than at the base (p < 0.05). Lung density decreased on identical location according to increase of PEEP (p < 0.05). There was no significant difference between right and left lung density at sternal and dorsal recumbency and no significant difference of the dorsal, ventral, and lateral portions of lung density at the right and left recumbency under identical pressure. It is implied that during chest CT scan with 20 mmHg of positive end expiratory pressure with right or left lateral recumbency, canine lung density do not influenced by gravity or anatomic location.

Radiographic Evaluation of Stiffness of Articular Eminence in the Temporomandibular Joint(TMJ) of Korean Using Dental cone-beam CT (한국인의 측두하악관절에서 Dental cone-beam CT를 이용한 관절융기의 경사도에 대한 방사선학적 평가)

  • Oh, Sang-Chun;Han, Ji-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.163-173
    • /
    • 2013
  • When the mandible performs opening movement, the condyle-disk complex conducts sliding movement along the articular eminence. Thus, anatomic configuration of articular eminence is very important to normal movement of TMJ. The purpose of this study was to measure the posterior slope of the articular eminence and evaluate the effect of a pathologic bone change in the condylar head on the stiffness of articular eminence, and compare the differences of the articular eminence slope by gender and age using dental cone-beam CT. As using i-CAT Cone-Beam Computed Tomography, the CT images of 204 TMJs of 102 patients(43 men and 59 women, mean age: 37.7 years) who were diagnosed at Wonkwang University Sanbon Dental Hospital were evaluated. All images were converted into a TMJ analysis mode to observe the continuous sagittal section images and coronal section images of the joints. To observe and assess bone changes in the condyle, three dentists measured the stiffness of the articular eminence on the same images, and when two of the three dentists agreed on their reading, these results were adopted and recorded. The articular eminence slope, considering the condylar anatomic configuration, was measured in three regions, namely, lateral part, central part, and medial part of the condyle. In the cases of a normal condyle(NCBC) and a condyle(CBC) with bone change, the articular eminence slopes were $57.0^{\circ}$(NCBC) and $51.8^{\circ}$(CBC) at the medial part, $57.9^{\circ}$(NCBC) and $52.4^{\circ}$(CBC) at the central part, and $55.1^{\circ}$(NCBC) and $49.5^{\circ}$(CBC) at the lateral part of the condyle. And the articular eminence slope of the condyle with bone change demonstrated less steepness than that of normal condyle (p<0.05). The articular eminence slope showed mediolaterally that it was the steepest at the central, followed by at the medial, and at the lateral (p<0.05). There were no significant differences by the gender and the age (p.0.05).

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

A Study on Availability about Positron Emission Mammography of Breast Cancer (유방암 환자의 Positron Emission Mammography에서의 유용성에 관한 연구)

  • Kim, Seung-Jeong;Kim, Jae-Il;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2010
  • Purpose: Until now the general study for breast cancer patient has been mammography, breast sonography for anatomic diagnostics and $^{18}F$-FDG whole body PET for functional one. But the PEM (Positron Emission Mammography) was developed to increase sensitivity, specificity and accuracy to improve the disadvantage of each study. Therefore this present study aims to describe availability of PEM for improving diagnosis of breast cancer. Materials and Methods: During 3 months from January in 2010, PEM was performed on 100 patients who had history of breast cancer. Using Naviscan's PEM Flex Solo II scanner, PEM images of breast were acquired. And then we evaluated sensitivity, specificity and accuracy of PEM data by comparing results of PEM images with postoperative pathologic finding. Results: On the 100 patients, it could reveal 89 true positive, 9 false positive, 7 false negative and 87 true negative. Thus the results of sensitivity, specificity and accuracy for PEM was evaluated 92.7%, 90.6% and 91.7%. Conclusion: The sensitivity, specificity and accuracy have been reported 83.7%, 68.5% and 77.1% in mammography, and that was 89.1%, 79.1% and 83.4% in breast sonography. However the results of PEM were more increased than others. Therefore the results of this study will be available that PEM used diagnosis with breast cancer, used preoperative operation plan and helps to discovery of a part recurrence.

  • PDF

Anthropometric Analysis of Facial Foramina in Korean Population: A Three-Dimensional Computed Tomographic Study

  • Lim, Jung-Soo;Min, Kyung-Hee;Lee, Jong-Hun;Lee, Hye-Kyung;Hong, Sung-Hee
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2016
  • Background: Position of the facial foramina is important for regional block and for various maxillofacial surgical procedures. In this study, we report on anthropometry and morphology of these foramina using three-dimensional computed tomography (3D-CT) data. Methods: A retrospective review was performed for all patients who have undergone 3D-CT scan of the facial skeleton for reasons other than fracture or deformity of the facial skeleton. Anthropometry of the supraorbital, infraorbital, and mental foramina (SOF, IOF, MF) were described in relation to facial midline, inferior orbital margin, and inferior mandibular margin (FM, IOM, IMM). This data was analyzed according to sex and age. Additionally, infraorbital and mental foramen were classified into 5 positions based on the anatomic relationships to the nearest perpendicular dentition. Results: The review identified 137 patients meeting study criteria. Supraorbital foramina was more often in the shape of a foramen (62%) than that of a notch (38%). The supraorbital, infraorbital, and mental foramina were located 33.7 mm, 37.1 mm, and 33.7 mm away from the midline. The mean vertical distance between IOF and IOM was 13.4 mm. The mean distance between MF and IMM was 21.0 mm. The IOF and MF most commonly coincided with upper and lower second premolar dentition, respectively. Between the sex, the distance between MF and IMM was significantly higher for males than for female. In a correlation analysis, SOF-FM, IOF-FM and MF-FM values were significantly increased with age, but IOF-IOM values were significantly decreased with age. Conclusion: In the current study, we have reported anthropometric data concerning facial foramina in the Korean population, using a large-scale data analysis of three-dimensional computed tomography of facial skeletons. The correlations made respect to patient sex and age will provide help to operating surgeons when considering nerve blocks and periosteal dissections around the facial foramina.

The Comparative Study of Alveolar Bone Level and Root Form of the Mandibular Molar on Radiographic Image and Clinical Examination (방사선사진과 임상검사에서 하악 대구치 치근의 형태학적 구조 및 치조골 수준에 관한 비교연구)

  • Park, Jung-Bae;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.281-292
    • /
    • 2004
  • Periodontal defects of the furcation are characterized by several inherent anatomic factors that can make successful periodontal therapy difficult and results unpredictable. The severity and rate of occurrence of periodontal disease are directly related to the location of the furcation relative to the cementa-enamel junction and anatomical form of the root by limiting the accessibility and effectiveness of the periodontal instrumentation. This study investigated the reliability and accuracy of panoramic radiograph diagnoses of the periodontal state of mandibular molars, particularly regarding the diagnosis of furcation area periodontal defects, treatment planning, and prognosis prediction. This study examined a total of 110 teeth belonging to 33 subjects (19 male, 14 female) presenting with incipient to moderate periodontitis 4-7mmpocket depth. The alveolar bone level, length and width of the root trunk, and root separation angle were measured using the panoramic radiograph and compared to the results taken directly by retracting a full-thickness flap. The results of the study are as follows: 1. Data regarding the alveolar bone level of the mandibular first molar showed that the directly taken surgical measurements resulted in $5.1{\pm}0.9mm$ that was slightly deeper than the corresponding panoramic measurement resulted in $4.8{\pm}0.8mm$, but these differences were statistically insignificant (p>0.05). 2. The data of the directly taken surgical measurement of the mandibular second molar $(5.1{\pm}1.1mm)$ was slightly deeper than the corresponding panoramic measurement $(4.7{\pm}1.2mm)$, but these differences were statistically insignificant (p>0.05). 3. The measured values of the length and width of the mandibular first molar root trunks were determined to be $4.1{\pm}0.6mm$ and $7.3{\pm}0.9mm$, respectively, while the values of the mandibular second molar root trunks were determined to be $4.6{\pm}1.3mm$ and $7.6{\pm}0.9mm$ respectively. The differences between these values were found to be statistically significant (p<0.01). 4. The measured values of the root separation angle showed that the mandibular first molars averaged $34.5{\pm}4.4^{\circ}$, while the mandibular second molars averaged $23.0{\pm}10.0^{\circ}$. The differences between these values were found to be statistically significant (p<0.01).

Prevalence of Abnormal Cervical Cytology in HIV-Negative Women Participating in a Cervical Cancer Screening Program in Calmette Hospital, Cambodia

  • Hav, Monirath;Eav, Sokha;Heang, Nicole;Pich, Pintuna;Lim, Davy;Leang, Vitou;Korn, Aun;Lay, Sanine;Pluot, Michel;Kruy, Leangsim
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3101-3103
    • /
    • 2016
  • Background: According to the most recent estimation of GLOBOCAN, Cambodia has the highest incidence and mortality rate of cervical cancer in Southeast Asia. A screen-and-treat strategy using visual inspection with acetic acid (VIA test) and cryotherapy has been implemented in Cambodia's national cervical cancer screening program since 2013. However, where resources are available, cervical cytology with or without high-risk HPV DNA testing is the preferred screening method used in this country. Aim: This study aims to calculate the prevalence of abnormal cervical cytology and explain the possible factors contributing to a reduced quality of cervical cytology among women participating in a hospital-based cervical cancer screening program in Cambodia. Materials and Methods: A descriptive study was conducted using information from the cytology and pathology database in the Department of Pathology of Calmette Hospital between January 2012 and December 2015. Prevalence of abnormal cervical cytology, based on the Bethesda 2001 classification, was calculated. Data on the adequacy of cytological specimens were analyzed in order to explain the factors contributing to a reduced quality of cervical cytology interpretation. Results: Among 6,207 women who participated in the cervical cancer screening program at Calmette Hospital during 2012 and 2015, 388 (6.25%) had abnormal cytology, which could be classified into Atypical Squamous Cells of Undetermined Significance (92 cases; 1.48%), Atypical Squamous Cells - Cannot Exclude High-Grade Intraepithelial Lesion (13 cases; 0.21%), Atypical Glandular Cells (11 cases; 0.18%), Low-Grade Squamous Intraepithelial Lesion (221 cases; 3.56%), High-Grade Squamous Intraepithelial Lesion (26 cases; 0.42%), and Squamous Cell Carcinoma (25 cases; 0.40%). Unsatisfactory smears made up 12.2% of the total cases. The most frequently identified factor leading to unsatisfactory smears was the absence of cells from the transformation zone. Conclusions: The present study showed an overall prevalence of abnormal cervical cytology of 6.25%, which is comparable to that in many large population-based studies in the Asia Pacific region. Nevertheless, the remarkably high rate of unsatisfactory smears in this study justifies further improvement in specimen sampling among Cambodian gynecologists.

A comparative study of established z score models for coronary artery diameters in 181 healthy Korean children

  • Ryu, Kyungguk;Yu, Jeong Jin;Jun, Hyun Ok;Shin, Eun Jung;Heo, Young Hee;Baek, Jae Suk;Kim, Young-Hwue;Ko, Jae-Kon
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.11
    • /
    • pp.373-378
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the statistical properties of four previously developed pediatric coronary artery z score models in healthy Korean children. Methods: The study subjects were 181 healthy Korean children, whose age ranged from 1 month to 15 years. The diameter of each coronary artery was measured using 2-dimensional echocardiography and converted to the z score in the four models (McCrindle, Olivieri, Dallaire, and Japanese model). Descriptive statistical analyses and 1-sample t tests were performed. Results: All calculated z scores had P values of ${\geq}0.050$ using the Kolmogorov-Smirnov test. The one sample t test showed that the mean z scores did not converge to zero except in 1 model, and the mean right coronary artery (RCA) z score was less than zero in all 4 models. The smaller RCA diameter in this study could be associated with the more distal measuring point used to avoid the conal branch. The percentage of subjects with extreme z score values (${\geq}2.0$ and ${\geq}2.5$) for the left main coronary artery (LMCA) seems to be higher in the Dallaire (4.9% and 3.3%) and Japanese models (7.1% and 3.8%). Conclusion: All 4 models showed statistical feasibility of normal distribution. More precise instructions would be needed for the measurement of the RCA. The higher percentage of extreme z scores for the LMCA is compatible with the basic understanding of anatomic variation in the LMCA.

Anatomical Study for Vascular Distribution of the Perforator of Deep Inferior Epigastric Artery in Koreans (한국인에 있어 깊은아래배벽동맥(Deep Inferior Epigastric Artery)의 천공지(Perforator)에 관한 해부학적 연구)

  • Kim, Jee Hoon;Lee, Paik Kwon;Rhie, Jong Won;Kim, Deog Im;Han, Seung Ho
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.28-35
    • /
    • 2008
  • Purpose: The pedicle of transverse rectus abdominis myocutaneous(TRAM) flap and deep inferior epigastric arterial perforator flap is deep inferior epigastic artery (DIEA) and accurate anatomic knowledge about perforator of DIEA is very important for the elevation of these flap. The authors investigated a detailed vascular network of perforator of DIEA in Koreans. Methods: 24 fresh cadavers were studied. Among them, 15 were examined based on the plain X-ray examination for the distribution and location of perforator of DIEA. And 9 fresh cadavers were examined based on the 3-dimensional computed tomography(CT) study for the distance between ending point of perforator of DIEA and mother artery, the distance between most medial mother artery and midline, the distance between most lateral mother artery and midline, and the running type of perforators of DIEA. Results: Based on the plain X-ray examination, suitable(external diameter$${\geq_-}0.5mm$$) perforators of DIEA are located between the level of umbilicus and 8 cm below it. Based on the 3D-CT study, average distance between the ending point of perforator of DIEA and the mother artery is 30.26 mm on the left, 28.62 mm on the right, respectively. The average distance between most medial mother artery and midline is 17.13 mm on the left, 15.76 mm on the right, respectively. The average distance between most lateral mother artery and midline is 56.31 mm on the left, 50.90 mm on the right, respectively. The main running course of suitable perforators of DIEA is type a, which is a direct musculocutaneous perforator vessel from main vascular axis passing outward to join the subdermal plexus, directly. Conclusion: 3-dimensional computed tomography study as well as plain X-ray examination provided more accurate and detail informations about perforators of DIEA in Koreans. These informations will help us understand the detailed vascular anatomy and operation with ease and safe in the lower abdomen of Koreans.

The New Finding on BOLD Response of Motor Acupoint KI6(照海) by fMRI (fMRI를 이용하여 수지굴신운동(手指屈伸運動)과 조해(照海)(KI6) 자침(刺鍼)에 의(依)한 대뇌운동피질(大腦運動皮質)의 활성변화(活性變化)에 관(關)한 비교(比較) 연구(硏究))

  • Kwon, Cheol-hyeon;Lee, Jun-beom;Hwang, Min-seob;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.6
    • /
    • pp.177-186
    • /
    • 2004
  • Introduction : Recent studies Suggested that there is a strong correlation between acupuncture stimulation and its related cortical activation. Anther study showed that either positive or negative BOLD effects could be observed depending on anatomical structure in acupuncture stimulation. In ttis study, we investigated a new acupoint $KI_6$ (照海), which was known as motor-related acupoint and obtained an evidence that the stimulation of $KI_6$ resulted in either negative or positive BOLD response to stimulation. Methods & Results : 1. Subjects and paradigms : Two separate stimulation paradigms were performed on five healthy (aged 22-23 yrs) in this study. First, the paradigm of acupuncture stimulation was that the acupuncture needle was inserted in acupoints $KI_6$, which is located in lateral side of the foot and then continuously twisted(補瀉를 除外한 捻轉法) for 70 seconds for 10 cycles of activation. During rest period (70 seconds), the needle was completed removed from acupoint. Total 60 cycles were performed and 10 images were obtained per cycle. Second, nonacupoint was randomly selected and the same paradigm was performed as acupoint stimulation. The stimulation protocol comprised 10 cycles of alternating. activation and rest (10 images per cycle). Total 60 cycles were performed and each cycle take about 1.5 sec for motor task. Subjects take an at least 15 minutes break before starting anther paradigm. 2. fMRI mapping : Multi-slice functional images were obtained on a 1.5T Magnetom Vision MRI scanner (Simens Medical, Erlangen, Germany) equipped with high performance whole-body gradients. The BOLD T2 * - weighted images were acquired with acho planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = $90_{\circ}$). The other sequence parameter are : FOV = 210 mm, matrix=$64{\times}128$ or $64{\times}64$, slice number=10 and slice thickness = 5 or 8 mm. the anatomic images were obtained with Spin-echo T1-weighted images. The resulting images were then anaiyzed with STIMULATE (CMRR, U. of Minnesota) to generate functional maps using a student T-test (p < 0.005) and cluster analysis. Both positive and negative response were evaluated. Conclusions : We have observed the activation of the motor cortex by stimulating motor-related acupoint ($KI_6$). Among five subjects, negative BOLD response was shown in four and positive response in one. All subjects showed positive response to conventional finger flexion-extension task. To understand the detailed mechanisms of correlation between acupuncture stimulation and BOLD fMRI changes and two typs of response, further study strongly required.

  • PDF