• Title/Summary/Keyword: Analysis of risk by fire

Search Result 332, Processing Time 0.029 seconds

Analyzing The Economic Impact of The Fire Risk Reduction at Regional Level in Goyang City (지역단위 화재 위험도 저감의 고양시 경제적 파급효과 분석)

  • Son, Minsu;Cho, Dongin;Park, Chang Keun;Ko, Hyun A;Jung, Seunghyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.685-693
    • /
    • 2021
  • This study examined the fire risk of the region in Goyang City using the spatial information data of buildings. The economic damage by industry was assessed according to the probability of fire risk. The study area was confined to Goyang-si, Gyeonggi-do, and the same fire risk reduction rate was applied to each region for the convenience of analysis. The possibility of fire was derived based on the buildings' density and usage in the area by National GIS building-integrated information standard data. The calculation of economic damage by industry in Goyang City due to the fire risk was calculated by combining the Goyang-si industry-related model produced by matching with 30 industrial categories in Input-Output Statistics of Korea Bank and 20 industrial categories in the Goyang-si business survey and the possibility of fire. The basic scenario of production impossibility during six months and business loss due to fire was established and analyzed based on the supply model. The analysis showed that Ilsan-dong-gu, Ilsan-seo-gu, and Deokyang-gu suffered the most economic damage. The "electricity, gas, steam, and water business" showed the greatest loss by industry.

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.

A Study on the Fire Risk of the Kimchi Refrigerator through Case Analysis of Fire Accidents (사례 분석을 통한 김치냉장고의 화재 위험성에 관한 연구)

  • Park, Nam Kyu;Ji, Hong Keun;Song, Jae Yong
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • In this paper, we describe fire risk of Kimchi refrigerator. The Kimchi refrigerator has been widely spread and used starting from the first half of 2000 and recently fire accidents caused by the Kimchi refrigerator emerged as social concern. In particular, in products of a specific manufacturer, it is not an environmental factor, but a characteristic that the fire is caused due to a defect of the product itself is shown. These features are judged to be formed by unique defects regardless of external factor by forming electrically arc mark in the relay element. In this paper, we analyzed the cause of the fire occurring in the Kimchi refrigerator and finally confirmed the characteristic that the fire occurred mainly in the relay element due to insufficient capacity of the relay element. Therefore, when a fire occurs in a product of the same maker as the Kimchi refrigerator mentioned in this paper, it is always judged that the inspection of the relay element should be carried out.

Fire Occurrence Pattern Analysis and Fire Risk Calculation of Jinju City (진주시 화재발생 패턴분석과 위험등급 산출)

  • Bae, Gyu Han;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.4
    • /
    • pp.151-157
    • /
    • 2014
  • Diverse and complex facilities have been on the increase in urban areas in accordance with rapid urbanization. Along the lines of the increase in facilities, the risk of fire has increased. In particular, fire accidents as well as traffic accidents accounted for the highest rate in artificial disasters. Therefore, the National Fire Information Systems managed by the National Emergency Management Agency (NEMA) appeared for the effective fire management. The NEMA has provided the public with the Internet services regarding information about fire outbreak since 2007. This study acquired data from both NEMA and the Jinju City Fire Department. It constructed the fire data of Jinju City and calculated the change in spatial density targeting fire, occurred in Jinju city with a view to examining the fire risk of facilities by conducting a time series analysis on the trends of fire outbreak over a span of periods between 2007 and 2013. It also conducted an analysis of Moran's I, Getis-Ord Gi. Therefore, it came to select higher hot spots in terms of fire location and fire density. In addition, it attempted to calculate the levels of fire hazard by drawing up the matrix of personal injury and property damage, depending on facilities to present the methods, which can predict the risk of fire occurrence in urban areas.

A Study on the Analysis of Fire Risk by Fire and the Improvement of Evacuation Equipment for Apartment (About Existing 16 or Fewer Storey Apartment) (공동주택의 화재위험성 분석 및 피난시설 개선에 관한 연구 (16층 이하의 기존 공동주택을 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon;Sa, Jae-Cheon;Nam, Jung-O
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.127-135
    • /
    • 2011
  • In this study, we assumed the kitchen fire raising the highest fire rate in apt. and analyzed the fire risk to use CFD in order to estimate the problem of evacuation equipment and the fire vulnerability of 16 or fewer storey apartment. Fire occurring in the kitchen is expended to the livingroom and other rooms. We analyzed that the temperature effected by heat was more than $60^{\circ}C$ after 90 sec in the entrance of apartment unit. If fire is early recognized by men and men don't escape in time, it have too huge demage to block the exit. When the evacuation equipment suggested in this study was installed in order to solve the problem of evacuation equipment, we analyzed that it was estimated more than safe in safety evaluation by heat and heat flux.

A Study on Risk Analysis by Type of Ceiling Material Based on Fire Theory (화재이론에 기초한 천장재 종류별 위험성 분석에 관한 연구)

  • Kim, HyeWon;Kim, YunSeong;Lee, ByeongHeun;Jin, SeungHyeon;Koo, InHyuk;Kwon, YoungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.116-117
    • /
    • 2021
  • In general, when a building fire occurs, the heat flow rises by buoyancy, which affects the temperature rise of the ceiling. In addition, when the ceiling ignites, the fire spreads rapidly due to horizontal spread and radiant heat. According to the fire investigation, most of the large fires have a common characteristic that the fire spreads to the ceiling and causes many casualties. Therefore, it is considered that it is necessary to review the fire risk of ceiling materials used in buildings to prevent the spread of fire to the ceiling. Therefore, in this study, combustion characteristics such as the amount of heat released and ignition time of each SMC, DMC, and gypsum board were checked using a Cone Calorimeter, and the ignition temperature was calculated by substituting them into the fire theory. As a result, the ignition temperature of SMC was 449K, that of DMC was 1492K, and that of gypsum board was 677K.

  • PDF

Research of the Fire to Minimization Damage Plan on High-rise Buildings (초고층 빌딩의 화재 피해 최소화 방안에 관한 연구)

  • Lee, Jung-Il;Lee, Geun-Tae
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.91-97
    • /
    • 2009
  • When the fire occur in a special place as High-rise building, find the solution from minimize the potential risk factors that caused to develop the human and materials damage by analysis. Through preventive activities are suppression of the fire occurrence or prevent the fire and extinguish the fire early. However, introduction of scientific suppression program could predict in advance the progress of the fire, or to block the path by using Intel Regent or Fire grid.

Analysis of Installation Environment and Fire Risk of Induction Motors Installed in the Curing Process of a Rubber Product Manufacturing Plant (고무제품제조공장의 가류공정에 설치된 유도전동기의 설치환경 및 화재위험성 분석)

  • Jong-Chan Lee;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.23-29
    • /
    • 2023
  • This study analyzed the fire status of a rubber product manufacturing factory based on 19 years of fire data. Through the analysis of the current state of fire, electrical fires accounted for 58.19%, and among electrical fires, motor fires were the highest at 26.21%. For the motor fire occurrence process, the curing process accounted for the highest rate of 51.9%. Therefore, the installation environment was investigated for the motor in the curing process, and it was confirmed that the motor's maximum ambient temperature exceeded 40℃. In particular, in the case of the motor for curing operation, the motor was installed in a separate motor room, so the average indoor temperature was 48.10℃ and the motor frame's maximum temperature was 72.80℃. In this study, the risk of motor fire was confirmed through a field survey, and a safety management plan was derived by finding a process with high fire risk and conducting an experiment on the motor's installation environment and electrical characteristics in that process.

A Study on Evacuees Risk Assesment for Application of Spatial Risk Information (공간위험정보를 적용한 대피자 위험성평가에 관한 연구)

  • Hong, Seungbum;Jang, Jae-Soon;Park, Hyun-A;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.8-12
    • /
    • 2015
  • Performance Based Design is evaluating after each calculatiuon ASET and RSET. Risk informaion values such as heat, smoke, toxic gas etc are extracted by FDS in this study. These Risk informaion values by FDS apply Artisoc (evacuation simulator). Building structure made $60m{\times}65m$, exit number is made 2 positions and people in this building are 50 ramdonly. 20 times (case1~case 20) simulated and analysis evacuees risk by evacuated route positions.