• Title/Summary/Keyword: Analysis of Difference Image

Search Result 1,324, Processing Time 0.039 seconds

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Phosphorus Phases in the Surface Sediment of the South Sea (남해 표층 퇴적물에서의 인의 존재상)

  • SON Jaekyung;LEE Tongsup;YANG Han Soeb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.5
    • /
    • pp.680-687
    • /
    • 1999
  • To understand the role of shelf sediment in phosphorus biogeochemical cycle, we carried out sequential sediment extraction (SEDEX) of P and porewater analysis on 14 core samples collected in the South Sea of Korea, SEDEX classified P-pools into 5 phases and results are grouped into two categories: reactive P (loosely sorbed-P and Fe bound-P) and refractory P (detrital inorganic-p, authigenic mineral-P and organic-P). Total P concentrations are decreased with sediment depth in all samples as a result of dissolution to porewater. Reactive P comprises about $20\~50\%$ of total P, and iron bound-P is the major form consisting $70\~80\%$ of reactive P-pool. Iron bound-P decreases sharply with depth. Depth profiles of dissolved P concentration in porewater show mirror image of iron bound-P, revealing the role of FeOOH as a regulator of reactive P supply to overlying water column. Authigenic mineral-P consists less than $5\%$ of total P, thus removal of reactive P by converting into refractory P seems inefficient in shelf sediment. This implies that continental shelf sediment sequesters P temporarily rather than permanently. Results show local variation. Nakdong estuary receiving large amount of terrigenous input shows the highest concentration of total P and reactive P. Here iron oxyhydroxides at the surface sediment control the water column flux of P from sediment. Although total P content at the surface is comparable (500$\~$600 ${\mu}g{\cdot}g^{-1}$) between the South Sea and East China Sea, the former contains more iron bound-P and less derital inorganic-P than the latter. Reasons for the difference seem due in part to particle texture, and to biological productivity which depends roughly on the distance from land.

  • PDF

SURVEY OF SELF-CONCEPT AND DEPRESSION-ANXIETY OF THE ELEMENTARY SCHOOL BOYS WITH LEARNING DISABILITIES (학습장애를 가진 초등학교 남학생의 자아상 개념과 우울-불안 특성 조사)

  • Kim, Bong-Soo;Seong, Deock-Kyu;Jung, Yeong;Yoo, Hee-Jung;Cho, Soo-Churl;Shin, Sung-Woong
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.12 no.1
    • /
    • pp.125-137
    • /
    • 2001
  • We investigated the self-concept, subjective depression, and state-trait anxiety of the school boys with learning disabilities(abbr. LD, n=86) and compared them with normal boys(n=52) using Piers-Harris Self-Concept Inventory, Child Depression Inventory(abbr. CDI), and State-Trait Anxiety Inventory(abbr. STAI). With regard to Piers-Harris Self-Concept Inventory total scores, there was no significant difference between two groups, but normal boys showed higher scores in intellectual and school status, physical appearance, and happiness-satisfaction subscales than patients with LD. The male patients with LD showed significantly higher ratings in CDI total scores, and CDI subscales - ineffectiveness, anhedonia, negative self-esteem than normal children. The patients with LD reported significantly higher state anxiety, but not trait anxiety. Correlation analyses revealed that self-concept decreased over time, and depression-anxiety increased across grades in the patients with LD, but not in normal children. Especially, negative mood, anhedonia, negative self-esteem subscales of CDI, and state-trait anxiety showed significant positive correlation with grades. In both groups, CDI scores were inversely correlated with Piers-Harris Self-Concept and positively with State-Trait anxiety. In conclusion, self-concept problems which were related with school achievement and self-esteem were more abundant in the patients with LD than normal children, self-image problem, depression and anxiety increased across grades. According to regression analysis, age, behavior subscale, intellectual-school status, anxiety, popularity, happiness-satisfaction, CDI-ineffectiveness, interpersonal problem, negative self-esteem, and state anxiety could explain the self-concept in the patients with LD, not in normal children. So, the self-concept of the patients with LD were found to be related to the school achievement and stress when comparing with peers. In conclusion, elementary school boys with LD showed lower self-concept, higher depression and anxiety, and these differences increased across grades. Since the patients with LD have concomitant depression and anxiety disorders, it is important that comorbidity with emotional problems should be explored and managed properly.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Development and Validation of Korean Composit Burn Index(KCBI) (한국형 산불피해강도지수(KCBI)의 개발 및 검증)

  • Lee, Hyunjoo;Lee, Joo-Mee;Won, Myoung-Soo;Lee, Sang-Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.163-174
    • /
    • 2012
  • CBI(Composite Burn Index) developed by USDA Forest Service is a index to measure burn severity based on remote sensing. In Korea, the CBI has been used to investigate the burn severity of fire sites for the last few years. However, it has been an argument on that CBI is not adequate to capture unique characteristics of Korean forests, and there has been a demand to develop KCBI(Korean Composite Burn Index). In this regard, this study aimed to develop KCBI by adjusting the CBI and to validate its applicability by using remote sensing technique. Uljin and Youngduk, two large fire sites burned in 2011, were selected as study areas, and forty-four sampling plots were assigned in each study area for field survey. Burn severity(BS) of the study areas were estimated by analyzing NDVI from SPOT images taken one month later of the fires. Applicability of KCBI was validated with correlation analysis between KCBI index values and NDVI values and their confusion matrix. The result showed that KCBI index values and NDVI values were closely correlated in both Uljin (r = -0.54 and p<0.01) and Youngduk (r = -0.61 and p<0.01). Thus this result supported that proposed KCBI is adequate index to measure burn severity of fire sites in Korea. There was a number of limitations, such as the low correlation coefficients between BS and KCBI and skewed distribution of KCBI sampling plots toward High and Extreme classes. Despite of these limitations, the proposed KCBI showed high potentials for estimating burn severity of fire sites in Korea, and could be improved by considering the limitations in further studies.

Marine Environmental Characteristics of Goheung Coastal Waters during Cochlodinium polykrikoides Blooms (Cochlodinium polykrikoides 적조 발생시의 한국 남해안 고흥 연안의 해양환경 특징)

  • Lee, Moon Ock;Kim, Byeong Kuk;Kim, Jong Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.3
    • /
    • pp.166-178
    • /
    • 2015
  • We investigated marine environmental characteristics of Goheung coastal areas in August where is known to be the first outbreak site of Cochlodinium polykrikoides (hereafter C. polykrikoides) blooms, based on the oceanographic data observed from 1993 to 2013 around the Korean southern coastal waters including Eastern China Sea by National Fisheries Research and Development Institute (NFRDI). The data of NOAA/NGSST satellite images as well as numerical simulation results by Seo et al. [2013] were also used for analysis. Water temperatures at the surface and bottom layers in Goheung coast, i.e. Narodo, were $25.0^{\circ}C$ and $23.7^{\circ}C$ so that they were higher than $23.8^{\circ}C$ and $19.4^{\circ}C$ in Geoje coast where is a reference site, respectively. In addition, salinities at the surface and bottom layers in Goheung coast were 31.78 psu and 31.98 psu so that they were a little higher than 31.54 psu at the surface but a little lower than 32.79 psu at the bottom in Geoje coast, respectively. That is, the differences in water temperature or salinity between the surface and bottom layers in Goheung coast in August were not large compared to Geoje coast. This suggests that stratification in Goheung coast in August is fairly weak or may not be established. In addition, the concentrations of DIN and DIP at the surface layer were 0.068 mg/L ($4.86{\mu}M$) and 0.015 mg/L ($5.14{\mu}M$) in Goheung coast while 0.072 mg/L ($5.14{\mu}M$) and 0.01 mg/L ($0.32{\mu}M$) in Geoje coast, so they did not indicate a meaningful difference. On the other hand, when C. polykrikoides blooms, water temperature and salinity in August at the station 317-22 ($31.5^{\circ}N$, $124^{\circ}E$) of the East China Sea, where is near the mouth of Yangtze River, were $27.8^{\circ}C$ and 31.61 psu, respectively. Thus, water temperature was much higher whereas salinity was almost similar compared to Goheung coast. Furthermore, concentrations of $NO_3-N$ and $PO_4-P$ in the East China Sea in August were remarkably high compared to Goheung coast. When C. polykrikoides blooms, according to not only the image data of satellites NOAA/NGSST but also numerical experiment results by Seo et al.[2013], the freshwater out of Yangtze River was judged to clearly affect the Korean southern coastal waters. Therefore, the supply of nutrients in terms of Yangtze River may greatly contribute to the outbreak of C. polykrikoides blooms in Goheung coast in summer.

The Cyber world of the Matrix as a typical type of 'Simulacre' (시뮬라크르의 전형(典型)으로서 매트릭스(Matrix)의 가상 세계)

  • 이종한
    • Archives of design research
    • /
    • v.17 no.1
    • /
    • pp.339-346
    • /
    • 2004
  • Matrix, produced by Larry & Andy Wachowski, was relatively precisely dealt with the cyber world. After the movie was released, it had a mania for the movie and was adopted into a various forms of cultural products. It was remade not only into the parodies of the other movies and TV programs, but also the clothes and miscellaneous items of the movie were reincarnated as an unique cultural trend. The cause of the popularity is the fresh storyline as well as the sophisticated visual effects and good-looking actors. The agony of the protagonist was connected with the people outside the movie who are yearning for the ideal world. He was confused at the fact that his circumstances which were believed as the real world were not tortally true, complicated between the sensually phisical truth and the spiritual truth and had an will for the freedom that would ransack the truth and save the other people from the fictitious world. Consequently, the movie has got sympathies with many audiences suggesting the situation that has no a firm belief of the reality, the difference between the real and the cyber world is meaningless and the faked images of the high-technology are overturned This thesis tries to study the present that the real images are excessly duplicated and consumed, related to the Jean Baudrillard's theory, 'Hyperreel'. Replaced the real objects by a technical programming in the Matrix world, there happens the image-violence that the true nature is slaughterred by images. In the world where the reproducts are more actual than the reality and pretends to be real, only semiotics are consumed and produced. That is to say, the tortally programmed images has no references and aims, therefore should be produced in an 'impediment-strategy' like a faked crisis. That is the step of 'Simulation' that artificially reincarnates the real. Based upon the Baudrillard's theory, 'Simulacre', this study tries to research today's post-modern situation that the boundary of the real world and the faked copy is vague and vanishing, through the analysis of the cyber world of the movie 'Matrix'.

  • PDF

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF

A Study of Influence of Filgrastim on PET/CT In Diffuse Large B cell Lymphoma (미만성 거대 B 세포 림프종 환자에서 Filgrastim 사용이 PET/CT 영상에 미치는 영향에 대한 고찰)

  • NamKoong, Hyuk;Park, Hoon-Hee;Ban, Yung-Gak;Kang, Sin-Chang;Kim, Sang-Kyoo;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.17-23
    • /
    • 2009
  • Purpose: It has been known that PET/CT is very valuable in follow-up study of diffuse large B cell lymphoma (DLBCL). Generally, in DLBCL, radiotherapy and chemotherapy has been progressed, because the lesion hasn‘t been limited to one site. And, it has lead to the decrease of leukocyte like neutropenia, due to myelosuppression of chemotherapy. So, in that case, administration of Filgrastim (Granulocyte colony-stimulating factor; G-CSF) is universal. However, in short time after administration, PET/CT has limitation to offer accurate images, through the uptake of $^{18}F$-FDG is increased in the region that is activated bone marrow by hematopoietic growth. Therefore, the aim of this study is that PET/CT in a certain period of time after administration of Filgrastim is able to show normal degree of $^{18}F$-FDG uptake. Materials and Methods: 10 patients under follow-up study of diffuse large B cell lymphoma were examined in this study from January, 2007 to January, 2009 (Male: 4 persons; Female: 6 persons; The mean age: 53.8 years old; The mean weight: 57.3 Kg). Using PET/CT (Discovery STe; GE Healthcare, Milwaukee, WI, USA), whole body images were acquired in 1 hour after $^{18}F$-FDG injection. For image analysis, each ROI ($120\;mm^2$) was drawn on $C^6$ (the sixth C-spine), $L_4$ (the forth L-spine), liver, spleen, and lung, then SUV (Standard Uptake Value)s were measured. We compared with each uptake between in 1-day and 5~7 days after administration of Filgrastim at same patient, so confirmed significance about these by SPSS version 12. Results: In case of $C_6$, $L_4$, spleen, every SUV of 1 day later was remarkably higher than that of 5~7 days later, but liver and lung were similar. Also, the images acquired after 5~7 days distinct remarkably and show normal degree of $^{18}F$-FDG uptake, because uptake of bone was almost disappeared. Conclusions: In this study, each SUV was prominent difference as a period of time after Filgrastim’s administration. And Filgrastim makes concentrate uptake of $^{18}F$-FDG in bone, but, after 5~7 days, bone‘s uptake was greatly decreased. Therefore, we are able to infer a certain period of time that shows normal degree of uptake, by numerical value proven. Also, we consider that this study contribute to advanced study about the other agent like Pegfilgrastim, Lenograstim besides Filgrastim, afterwards.

  • PDF