• Title/Summary/Keyword: Analysis Solution

Search Result 10,383, Processing Time 0.047 seconds

Application of Hyperbolic Two-fluids Equations to Reactor Safety Code

  • Hogon Lim;Lee, Unchul;Kim, Kyungdoo;Lee, Won-Jae
    • Nuclear Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.45-54
    • /
    • 2003
  • A hyperbolic two-phase, two-fluid equation system developed in the previous work has been implemented in an existing nuclear safety analysis code, MARS. Although the implicit treatment of interfacial pressure force term introduced in momentum equation of the hyperbolic equation system is required to enhance the numerical stability, it is very difficult to implement in the code because it is not possible to maintain the existing numerical solution structure. As an alternative, two-step approach with stabilizer momentum equations has been selected. The results of a linear stability analysis by Von-Neumann method show the equivalent stability improvement with fully-implicit solution method. To illustrate the applicability, the new solution scheme has been implemented into the best-estimate thermal-hydraulic analysis code, MARS. This paper also includes the comparisons of the simulation results for the perturbation propagation and water faucet problems using both two-step method and the original solution scheme.

Micro-Structural Enhancement of XLPE Insulation Using Additive Diffusion Method

  • Park, Se-Eun;Shim, Sung-Ik;Cho, Dae-Hee;Youn, Bok-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.238-239
    • /
    • 2005
  • With the aim of developing XLPE insulation for extra high voltage cable, we investigated the morphology of cross-linked polyethylene. We used a kind of base materials and additives, and controlled curing condition and amount of additives. The effect of addition of additives on morphology of XLPE such as lamellar density, orientation and additive layer were analyzed using TEM analysis. We applied this result to diffused additive amount was analyzed using FT-IR analysis, and the change of microstructure as the degree of additive diffusion was analyzed using TEM analysis.

  • PDF

On the Relationship between $\varepsilon$-sensitivity Analysis and Sensitivity Analysis using an Optimal Basis

  • Park, Chan-Kyoo;Kim, Woo-Je;Park, Soondal
    • Management Science and Financial Engineering
    • /
    • v.10 no.2
    • /
    • pp.103-118
    • /
    • 2004
  • $\epsilon$-sensitivity analysis is a kind of methods for performing sensitivity analysis for linear programming. Its main advantage is that it can be directly applied for interior-point methods with a little computation. Although $\epsilon$-sensitivity analysis was proposed several years ago, there have been no studies on its relationship with other sensitivity analysis methods. In this paper, we discuss the relationship between $\epsilon$-sensitivity analysis and sensitivity analysis using an optimal basis. First. we present a property of $\epsilon$-sensitivity analysis, from which we derive a simplified formula for finding the characteristic region of $\epsilon$-sensitivity analysis. Next, using the simplified formula, we examine the relationship between $\epsilon$-sensitivity analysis and sensitivity analysis using optimal basis when an $\epsilon$-optimal solution is sufficiently close to an optimal extreme solution. We show that under primal nondegeneracy or dual non degeneracy of an optimal extreme solution, the characteristic region of $\epsilon$-sensitivity analysis converges to that of sensitivity analysis using an optimal basis. However, for the case of both primal and dual degeneracy, we present an example in which the characteristic region of $\epsilon$-sensitivity analysis is different from that of sensitivity analysis using an optimal basis.

A Novel Framework for Optimal IC Design and Statistical Analysis (최적의 IC 설계와 통계적 분석을 위한 새로운 설계 환경)

  • 이재훈;김경호;김영길;김경화
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.3
    • /
    • pp.77-86
    • /
    • 1994
  • A New environment SENSATION for circuit optimization and statistical analysis has been developed. It provides real time simulation and includes automatic algorithms to assist for reaching optimal solution. Furthermore, statistical analysis environment is presented which aids in Monte Carlo analysis. worst case corner analysis, and sensitivity analysis. These capabilities faciliate the characterization of the effects of several operating conditions and manufacture process paramenters on the design performances. We verify that the proposed methods can obtain the optimal solution of the objective function through several experimental results.

  • PDF

An FCA-based Solution for Ontology Mediation

  • Cure, Olivier;Jeansoulin, Robert
    • Journal of Computing Science and Engineering
    • /
    • v.3 no.2
    • /
    • pp.90-108
    • /
    • 2009
  • In this paper, we present an ontology mediation solution based on the methods frequently used in Formal Concept Analysis. Our approach of mediation is based on the existence of instances associated to two source ontologies, then we can generate concepts in a new ontology if and only if they share the same extent. Hence our approach creates a merged ontology which captures the knowledge of these two source ontologies. The main contributions of this work are (i) to enable the creation of concepts not originally in the source ontologies, (ii) to propose a solution to label these emerging concepts and finally (iii) to optimize the resulting ontology by eliminating redundant or non pertinent concepts. Another contribution of this work is to emphasize that several forms of mediated ontology can be defined based on the relaxation of certain criteria produced from our method. The solution that we propose for tackling these issues is an automatic solution, meaning that it does not require the intervention of the end-user, excepting for the definition of the common set of ontology instances.

Impact response analysis of delaminated composite laminates using analytical solution (이론 해를 이용한 층간 분리된 적층판의 충격거동 해석)

  • Kim, Sung-Joon;Shin, Jeong-Woo;Chae, Dong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.315-320
    • /
    • 2007
  • An analytical solution has been developed for the impact response of delaminated composite plates. The analysis is based on an expansion of loads, displacements, and rotations in a Fourier series which satisfies the end boundary conditions of simply-supported. The analytical formulation adopts the Laplace transformation technique, requiring a linearization of contact deformation. In this paper, the nonlinear contact stiffness is replaced by a linearized stiffness, to provide an estimate of the additional compliance due to contact area deformation effects. It has been shown that defects such as delaminations may be modeled as spring stiffness. The change in the impact characteristics as this spring stiffness has been investigated theoretically. Predicted impact responses using analytical solution are compared with the numerical ones from the 3-D non-linear finite element model. From the results, it is shown that analytical solution was found to be reliable for predicting the impact response.

  • PDF

Computational Analysis of Aqueous Solution Stability for Electroformed Fe-Cr-Ni Thin Layer (전산모사를 활용한 Fe-Cr-Ni 전주용 수용액의 안정성 분석)

  • Jeon, Seung-Hwan;Han, Sang-Seon;Kim, Ma-Ro;Choe, Yong;Lee, Sang-Beom
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2014.11a
    • /
    • pp.214-214
    • /
    • 2014
  • Computational analysis of aqueous solution stability of Fe-Cr-Ni system to find an electroplating condition of Fe-Cr-Ni layer. Aqueous sulfate solution with iron, chromium and nickel ions was selected by using a numerical S/W with which aqueous solution stability was analyzed. Several possible conditions to perform electro-forming of Fe-Cr-Ni were selected with thermo-dynamical data. The Fe-Cr-Ni system was electro-formed which composition and microstructure of the electroplated Fe-Cr-Ni significantly depended on the solution temperature and electro-potential. The final composition of Fe-3%Cr-48%Ni with less than $30{\mu}m$ thick was well electroplated.

  • PDF

Analytical solutions for skewed thick plates subjected to transverse loading

  • Chun, Pang-Jo;Fu, Gongkang;Lim, Yun Mook
    • Structural Engineering and Mechanics
    • /
    • v.38 no.5
    • /
    • pp.549-571
    • /
    • 2011
  • This paper presents analytical solutions for skewed thick plates under transverse loading that have previously been unreported in the literature. The thick plate solution is obtained in a framework of an oblique coordinate system. The governing equation is first derived in the oblique coordinate system, and the solution is obtained using deflection and rotation as partial derivatives of a potential function developed in this research. The solution technique is applied to three illustrative application examples, and the results are compared with numerical solutions in the literature and those derived from the commercial finite element analysis package ANSYS 11. These results are in excellent agreement. The present solution may also be used to model skewed structures such as skewed bridges, to facilitate efficient routine design or evaluation analyses, and to form special elements for finite element analysis. At the same time, the analytical solution developed in this research could be used to develop methods to address post-buckling and dynamic problems.

Precise Analytical Solution for the Peak Gain of LLC Resonant Converters

  • Hong, Sung-Soo;Cho, Sang-Ho;Roh, Chung-Wook;Han, Sang-Kyoo
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.680-685
    • /
    • 2010
  • Although LLC resonant converters have the advantages of a wide operation range and high efficiency, the lack of an analytical solution for the peak gain makes it difficult to optimize the resonant tank design, when considering not only the normal condition but also the holdup time requirement. In this paper, based on a mathematical analysis of a LLC resonant converter at the peak gain point, an analytical solution for the peak gain has been developed. By using the developed analytical solution, the peak gain with given resonant tank parameters can be obtained. To confirm the validity of the developed analytical solution, simulations and experimental results are compared.

A study for development of high speed hard chrome plating solution (고속 경질 크롬 도금 용액 개발에 관한 연구)

  • 추현식;이홍로
    • Journal of the Korean institute of surface engineering
    • /
    • v.25 no.5
    • /
    • pp.263-269
    • /
    • 1992
  • To enhancing efficiency of hard chrome plating solution more highly, cathode current efficiency were surveyed connected with hardness of deposits, surface morphology, TEM analysis and corrosion test of anode materials. Efficiency war increased up to 26% values by adding catalyst and two kind of additives. With given bath composition and 6$0^{\circ}C$, 60A/d$\m^2$ electrolosis conditionss bright and micro cracked deposits were well obtained, which showed HV 1000 values. From corrosion tests, anode materials such as Pb-Te (0.02%) and Pb-Ag(1%) showed most anti-corrosive results. Through SEM micrograph observations, ef-fects of additives on levelling, brightness and micro crack properties of hard chrome deposits could be con-firmed. Also, through TEM analysis the fact that deposits from crack free solution or high speed solution were more fine than from sargent solution could be confirmed.

  • PDF