• 제목/요약/키워드: Analysis Result

검색결과 53,951건 처리시간 0.07초

철근콘크리트 보통전단벽의 전단력 증폭효과 근사해석 (Approximate Analysis for Shear Force Amplification Effect in Ordinary RC Shear Walls)

  • 전성하;박지훈
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.129-139
    • /
    • 2020
  • An approximate analysis method is proposed to predict the dynamic amplification of shear forces in ordinary reinforced concrete shear walls as a preliminary study. First, a seismic design for three groups of ordinary reinforced concrete shear walls higher than 60 m was created on the basis of nonlinear dynamic analysis. Causes for the dynamic amplification effect of shear forces were investigated through a detailed evaluation of the nonlinear dynamic analysis result. A new modal combination rule was proposed on the basis of that observation, in which fundamental mode response and combined higher mode response were summed directly. The fundamental mode response was approximated by nonlinear static analysis result, while higher mode response was computed using response spectrum analysis for equivalent linear structural models with the effective stiffness based on the nonlinear dynamic analysis result. The proposed approximate analysis generally predicted vertical distribution of story shear and shear forces of individual walls from the nonlinear dynamic analysis with comparable accuracy.

비점원 오염부하량 산정에 관한 연구 (A Study on The Non-Point Source Pollutant Load Routing Method)

  • 김영섭;이관영
    • 한국산업융합학회 논문집
    • /
    • 제11권1호
    • /
    • pp.11-18
    • /
    • 2008
  • After execute quantitative analysis that choose station and compose floodgate quality of water net and use floodgate data and quality of water data analysis target Sign of the cock as 1 dimension access for Non-point pollution source pollution and estimate of Gaeuncheon's at Kyongsangbukdo report to the Throne in this research, presented parameter conclusion notation model (AGNPS) in real condition of our agricultural area through comparison with spot value and result is as following in reply. With result observation and analysis result of the AGNPS model the comparison which it will pay from the hazard which it analyzes 2005, the rainfall thought which is used in the analysis to select 8 heavy rain thoughts 2005 July - is data until of September. Actual amount of rainfall 6.0~195.0 mm one time the antecedent precipitation showed API5 case 0.0~507.0mm and were observed peak flows (Qpeak) each from the P-1 $0.026m^3/sec{\sim}9.265m^3/sec$, from the P-2 $0.010m^3/sec-2.747m^3/sec$ and from the P-3c $0.064m^3/sec-13.482m^3/sec$ to show. Also amendment AMC condition it will be cool and it uses and the AGNPS model conference the result which it occurs, analysis and regression analysis of actual flow for as 0.992 very the possibility of getting the result which is good there was a decisive coefficient which is cool. But the gun is (T-P) with the total nitrogen (T-N) decisive coefficient each as 0.794 and 0.849 the presumption which is reliability generally will pay and with the fact that it will be the possibility of getting it is judged.

  • PDF

강재의 대변형 예측을 위한 해석의 정도 (Accuracy of Analysis for Prediction of Large Deformation in Steel Members)

  • 장갑철;최의홍;장경호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.225-231
    • /
    • 2005
  • In this paper, to prediction of large deformation behavior of steel structures under loading, 3-Dimensional elastic-plastic FE analysis method is developed by using finite deformation theory and proposed cyclic plasticity model. The accuracy of developed analytical method was verified by comparison of experiment result and analysis results using infinitesimal deformation theory. The good agreement between analysis result by developed analytical method and experiment result is shown. Proposed 3-dimensional FE analysis using finite deformation theory and cyclic plasticity hysteresis model can be predict the large deformation of steel members under cyclic loading.

  • PDF

하이브리드 몰드 변압기의 온도 특성 해석 (Temperature Characteristics Analysis of Hybrid Transformer)

  • 김종왕;박훈양;이향범
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.931-936
    • /
    • 2013
  • In this paper, the temperature distribution of 400kVA hybrid transformer is predicted by using CFD analysis. The copper loss and iron loss which are heat source are calculated by using Joule heat and Bertotti's equation respectively. To improve the convergence of the numerical calculation and to reduce the computation time, the 1/4 model is used and the incompressible air model is used for external air. To verify analysis result, the temperature rise test and no-load test of the transformer are performed. The experiment result obtained by using thermo-graphic camera is similar to the numerical result of the CFD analysis.

각종 음성분석 상용 프로그램의 모음 기본주기 분석 결과 비교 (Comparison of vowel pitch results among several commercial voice analysis programs)

  • 남기창;이승훈;최재남;최홍식;남도현;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.54-56
    • /
    • 2005
  • Analysis of the voice and its corresponding studies are examined from the recording of the voice through microphone and various calculation processes of the signals by using computer. Voice analyser include data acquisition and analyzing program. Since oath program uses different voice signal processing algorithm, thorough understanding of the operation is essential. In this study, analysis result of patient voice were compared by using four different voice analysis programs such as MDVP, Praat, TF32, and the program developed in this study. Pitch, jitter and shimmer were selected as comparison analysis factors. As a result, pitch, jitter and shimmer showed different result since each program uses different pitch computation algorithm.

  • PDF

세계 커피시장의 소비실태 및 수출입 동향 비교 분석 고찰 - 한국.미국.일본 시장을 중심으로 - (The Analysis toward Consumption State, Import and Export in the World Coffee Market - The Case of Korea, U.S.A., Japan Market -)

  • 강석우;나영선
    • 한국조리학회지
    • /
    • 제10권3호
    • /
    • pp.65-82
    • /
    • 2004
  • This research is to make an attempt the analysis award consumption state, import and export in the world coffee market. This research results were as follows. First, The result of the analysis of Korea coffee market, imports of green bean were 1,316,000 bags from export countries in 2000. Re-exports of processed coffee were 71,000 bags in 2000. Main suppliers were Brazil, Viet Nam, Honduras, Colombia, Indonesia. Second, The result of the analysis of United State coffee market, imports of all forms of coffee were 19.29 million bags. Main suppliers were Brazil(15%), Viet Nam(15%), Colombia(17%) etc. Third, The result of the analysis of Japan market, imports of green beans were 6.37million bags in 2001. Re-exports of processed coffee were 166.000million bags. Consumption per head in 2001 was about 3.5 kg and Japanese coffee consumer now drink on average 11.0 cups per week.

  • PDF

컨테이너선 Bottom Floor 두께 최적화에 대한 연구 (A Study on Thickness Optimization of Bottom Floor for Container Ship)

  • 이아미;유영웅;이준혁;유영규
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2011년도 특별논문집
    • /
    • pp.95-100
    • /
    • 2011
  • In general, thickness of bottom floor in fore/aft cargo hold region for container ship has been determined based on FEM analysis result of mid cargo hold region. But this approach has room for improvement because section shape and frame spacing in fore/aft cargo hold of container ship are quietly different from those of mid cargo hold. From this study, correlation between FEM result and grillage analysis result has been investigated and simple method for thickness determination of bottom floor in fore/aft cargo hold using newly improved grillage analysis is proposed.

  • PDF

도시형 자기부상열차의 전력특성 분석에 관한 연구 (A Study on Electric Power Supply Analysis of Urban MAGLEV Vehicle)

  • 안영훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.157-161
    • /
    • 2008
  • The main purpose of this study is to analysis of urban MAGLEV vehicle for the Incheon International Airport Maglev railway, in the process of construction at the moment, in Korea. For analysis of urban MAGLEV, we have measurement power a special quality of MAGLEV operating the center science museum in Deajeon. 1) The power property related to urban MAGLEV vehicle demand on the Incheon International Airport Maglev railway track and substation capacity compared to the result given. 2) The optimum design of substation is determined based on the analysis. 3) The equipments of substation are determined based on the analysis. The result of measurement performance, therefore, enables us to reflect the good property, to the power supply design. The result of research performance, therefore, enables us to reflect the Power Supply System design for the stabilized and economized MAGLEV operation.

  • PDF

요철단면 SC보의 휨 내력에 관한 연구 (A Study on Flexural Strength of Prominent Section of SC Beams)

  • 류수현;안형준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.197-204
    • /
    • 2006
  • 본 연구는 전단연결재 없이 부착면적을 확대한 요철 단면SC보의 휨 거동을 실험하여 이론 해석 및 상용 구조해석 프로그림인 ANSYS해석 결과와 비교 강판과 콘크리트의 부착성능과 초기강성 등을 분석하였고 이를 통해 효율적인 SC보의 실용화를 위한 기초 연구 자료를 제공하고자 한다. 실험결과는 이론값의 88%-98% 정도의 내력을 발휘한 것으로 나타났으며, 합성율은 분석결과 30-70%로 완전합성에 이르지 못한 것으로 나타나 완전합성을 발휘할 수 있는 접합방법의 필요성을 확인할 수 있었다.

OZIPR 모델링 결과의 민감도 분석 (A Sensitivity Analysis of the OZIPR Modeling Result for the Seoul Metropolitan Area)

  • 이선화;;김용표
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.99-108
    • /
    • 2011
  • To establish area specific control strategies for the reduction of the ozone concentration, the Ozone Isopleth Plotting Package for Research(OZIPR) model has been widely used. However, the model results tend to changed by various input parameters such as the background concentration, emission amount of NOx and volatile organic compounds (VOCs), and meteorological condition. Thus, sensitivity analysis should be required to ensure the reliability of the result. The OZIPR modeling results for five local government districts in the Seoul Metropolitan Area (SMA) in June 2000 were used for the sensitivity analysis. The sensitivity analysis result showed that the modeling result of the SMA being VOC-limited region be still valid for a wide range of input parameters' variation. The estimated ozone concentrations were positively related with the initial VOCs concentrations while were negatively related with the initial NOx concentrations. But, the degree of the variations at each local district was different suggesting area specific characteristics being also important. Among the five local governments, Suwon was chosen to identify other variance through the period from April to September in 2000. The monthly modeling results show different ozone values, but still showing the characteristics of VOCs-limited region. Limitations due to not considering long range transport and transfer from neighbor area, limitation of input data, error between observed data and estimated data are all discussed.