• Title/Summary/Keyword: Analysis Mode

Search Result 8,127, Processing Time 0.035 seconds

Estimation of Internal Motion for Quantitative Improvement of Lung Tumor in Small Animal (소동물 폐종양의 정량적 개선을 위한 내부 움직임 평가)

  • Yu, Jung-Woo;Woo, Sang-Keun;Lee, Yong-Jin;Kim, Kyeong-Min;Kim, Jin-Su;Lee, Kyo-Chul;Park, Sang-Jun;Yu, Ran-Ji;Kang, Joo-Hyun;Ji, Young-Hoon;Chung, Yong-Hyun;Kim, Byung-Il;Lim, Sang-Moo
    • Progress in Medical Physics
    • /
    • v.22 no.3
    • /
    • pp.140-147
    • /
    • 2011
  • The purpose of this study was to estimate internal motion using molecular sieve for quantitative improvement of lung tumor and to localize lung tumor in the small animal PET image by evaluated data. Internal motion has been demonstrated in small animal lung region by molecular sieve contained radioactive substance. Molecular sieve for internal lung motion target was contained approximately 37 kBq Cu-64. The small animal PET images were obtained from Siemens Inveon scanner using external trigger system (BioVet). SD-Rat PET images were obtained at 60 min post injection of FDG 37 MBq/0.2 mL via tail vein for 20 min. Each line of response in the list-mode data was converted to sinogram gated frames (2~16 bin) by trigger signal obtained from BioVet. The sinogram data was reconstructed using OSEM 2D with 4 iterations. PET images were evaluated with count, SNR, FWHM from ROI drawn in the target region for quantitative tumor analysis. The size of molecular sieve motion target was $1.59{\times}2.50mm$. The reference motion target FWHM of vertical and horizontal was 2.91 mm and 1.43 mm, respectively. The vertical FWHM of static, 4 bin and 8 bin was 3.90 mm, 3.74 mm, and 3.16 mm, respectively. The horizontal FWHM of static, 4 bin and 8 bin was 2.21 mm, 2.06 mm, and 1.60 mm, respectively. Count of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.10, 4.83, 5.59, 5.38, and 5.31, respectively. The SNR of static, 4 bin, 8 bin, 12 bin and 16 bin was 4.18, 4.05, 4.22, 3.89, and 3.58, respectively. The FWHM were improved in accordance with gate number increase. The count and SNR were not proportionately improve with gate number, but shown the highest value in specific bin number. We measured the optimal gate number what minimize the SNR loss and gain improved count when imaging lung tumor in small animal. The internal motion estimation provide localized tumor image and will be a useful method for organ motion prediction modeling without external motion monitoring system.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Categorizing Quality Features of Franchisees: In the case of Korean Food Service Industry (프랜차이즈 매장 품질요인의 속성분류: 국내 외식업을 중심으로)

  • Byun, Sook-Eun;Cho, Eun-Seong
    • Journal of Distribution Research
    • /
    • v.16 no.1
    • /
    • pp.95-115
    • /
    • 2011
  • Food service is the major part of franchise business in Korea, accounting for 69.9% of the brands in the market. As the food service industry becomes mature, many franchisees have struggled to survive in the market. In general, consumers have higher levels of expectation toward service quality of franchised outlets compared that of (non-franchised) independent ones. They also tend to believe that franchisees deliver standardized service at the uniform food price, regardless of their locations. Such beliefs seem to be important reasons that consumers prefer franchised outlets to independent ones. Nevertheless, few studies examined the impact of qualify features of franchisees on customer satisfaction so far. To this end, this study examined the characteristics of various quality features of franchisees in the food service industry, regarding their relationship with customer satisfaction and dissatisfaction. The quality perception of heavy-users was also compared with that of light-users in order to find insights for developing differentiated marketing strategy for the two segments. Customer satisfaction has been understood as a one-dimensional construct while there are recent studies that insist two-dimensional nature of the construct. In this regard, Kano et al. (1984) suggested to categorize quality features of a product or service into five types, based on their relation to customer satisfaction and dissatisfaction: Must-be quality, Attractive quality, One-dimensional quality, Indifferent quality, and Reverse quality. According to the Kano model, customers are more dissatisfied when Must-be quality(M) are not fulfilled, but their satisfaction does not arise above neutral no matter how fully the quality fulfilled. In comparison, customers are more satisfied with a full provision of Attactive quality(A) but manage to accept its dysfunction. One-dimensional quality(O) results in satisfaction when fulfilled and dissatisfaction when not fulfilled. For Indifferent quality(I), its presence or absence influences neither customer satisfaction nor dissatisfaction. Lastly, Reverse quality(R) refers to the features whose high degree of achievement results in customer dissatisfaction rather than satisfaction. Meanwhile, the basic guidelines of the Kano model have a limitation in that the quality type of each feature is simply determined by calculating the mode statistics. In order to overcome such limitation, the relative importance of each feature on customer satisfaction (Better value; b) and dissatisfaction (Worse value; w) were calculated following the formulas below (Timko, 1993). The Better value indicates how much customer satisfaction is increased by providing the quality feature in question. In contrast, the Worse value indicates how much customer dissatisfaction is decreased by providing the quality feature. Better = (A + O)/(A+O+M+I) Worse = (O+M)/(A+O+M+I)(-1) An on-line survey was performed in order to understand the nature of quality features of franchisees in the food service industry by applying the Kano Model. A total of twenty quality features (refer to the Table 2) were identified as the result of literature review in franchise business and a pre-test with fifty college students in Seoul. The potential respondents of our main survey was limited to the customers who have visited more than two restaurants/stores of the same franchise brand. Survey invitation e-mails were sent out to the panels of a market research company and a total of 257 responses were used for analysis. Following the guidelines of Kano model, each of the twenty quality features was classified into one of the five types based on customers' responses to a set of questions: "(1) how do you feel if the following quality feature is fulfilled in the franchise restaurant that you visit," and "(2) how do you feel if the following quality feature is not fulfilled in the franchise restaurant that you visit." The analyses revealed that customers' dissatisfaction with franchisees is commonly associated with the poor level of cleanliness of the store (w=-0.872), kindness of the staffs(w=-0.890), conveniences such as parking lot and restroom(w=-0.669), and expertise of the staffs(w=-0.492). Such quality features were categorized as Must-be quality in this study. While standardization or uniformity across franchisees has been emphasized in franchise business, this study found that consumers are interested only in uniformity of price across franchisees(w=-0.608), but not interested in standardizations of menu items, interior designs, customer service procedures, and food tastes. Customers appeared to be more satisfied when the franchise brand has promotional events such as giveaways(b=0.767), good accessibility(b=0.699), customer loyalty programs(b=0.659), award winning history(b=0.641), and outlets in the overseas market(b=0.506). The results are summarized in a matrix form in Table 1. Better(b) and Worse(w) index indicate relative importance of each quality feature on customer satisfaction and dissatisfaction, respectively. Meanwhile, there were differences in perceiving the quality features between light users and heavy users of any specific franchise brand in the food service industry. Expertise of the staffs was labeled as Must-be quality for heavy users but Indifferent quality for light users. Light users seemed indifferent to overseas expansion of the brand and offering new menu items on a regular basis, while heavy users appeared to perceive them as Attractive quality. Such difference may come from their different levels of involvement when they eat out. The results are shown in Table 2. The findings of this study help practitioners understand the quality features they need to focus on to strengthen the competitive power in the food service market. Above all, removing the factors that cause customer dissatisfaction seems to be the most critical for franchisees. To retain loyal customers of the franchise brand, it is also recommended for franchisor to invest resources in the development of new menu items as well as training programs for the staffs. Lastly, if resources allow, promotional events, loyalty programs, overseas expansion, award-winning history can be considered as tools for attracting more customers to the business.

  • PDF

Resolution of the Triacylglycerols Containing Conjugate Trienoic Acids into Their Molecular Species by HPLC in the Reversed-phase and Silver Ion Mode (Reversed-phase 및 $Ag^{+}$-HPLC에 의한 Conjugate Trienoic Acid 함유(含有) Triacylglycerol 분자종(分子種)의 상호분리(相互分離))

  • Kim, Seong-Jin;Woo, Hyo-Kyeng;Joh, Yong-Goe
    • Journal of the Korean Applied Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.197-213
    • /
    • 2001
  • Conjugate trienoic acids (CTA) occurred in triacylglycerols (TGs) of the seed oils of Trichosanthes kirilowii, Momordica charantia and Aleurites fordii, and they were easily converted to their methyl esters in a mixture of sodium methoxide-methanol without any structural destruction. The main fatty acids in triacylglycerol (TG) fraction of the seed oils of Trichosanthes kirilowii are $C_{18:2{\omega}6}$ (32.2 mol %), $C_{18:3{\;}9c.11t,13c}$ (38.0 mol %) and $C_{18:1{\omega}9}$ (11.8 mol %), followed with $C_{16:0}$ (4.8 mol %) and $C_{18:0}$ (3.1 mol %). The TG fraction was resolved into 20 TG molecular species according to the partition number (PN) by reversed-phase (RP)-HPLC. The main TG species were $DT_{c2}$, $MDT_{c}$ and $D_{2}T_{c}$, of which amounts reached 63 mol % of total TG molecular species. The TG sample was fractionated into 11 fractions according to the number of double bond in the molecule by $Ag^{+}-HPLC$ and the species of $DT_{c2}$, $MDT_{c}$ and $D_{2}T_{c}$ were also eluted as main components. The TG species containing CTA showed unusual behaviours in the order of elution by HPLC ; first, TG moleular species of $DT_{c2}$ (D; dienoic acid, $T_{c}$; punicic acid, $T_{ci}$; ${\alpha}-eleostearic$ acid, M ; monoenoic acid, $S_{t}$; stearic acid) was eluted earlier than $Mt_{c2}$, although they have the same PN number of 40, and, secondly, the species of $DT_{ci2}$ with eight double bonds was eluted earlier than that of $D_2T_{ci}$ with seven double bonds. Intact TG of the seed oils of Momordica charantia contained mainly fatty acids such as $C_{18:3{\omega}9c,11t,13t}$ (57.7 mol %), $C_{18:1{\omega}9}$ (17.4 mol %), $C_{18:0}$ (12.3 mol %) and $C_{18:2{\omega}6}$ (10.6 mol %), and was classified into 13 fractions by RP-HPLC. The main TG species were as follows ; $MT_{ci2}$ [$(C_{18:1{\omega}9})(C_{18:3\;9c,11t,13t})_{2}$, 39.1 mol %] and $S_{t}T_{ci2}$ [$(C_{18:0})(C_{18:3\;9c,11t,13t})_2$, 33.9 mol %] comprising about 73 mol % of total TG species, accompanied by $DT_{ci2}$ [$(C_{18:2{\omega}6})(C_{18:3\;9c,11t,13t})_{2}$, 7.3 mol %], $D_{2}T_{ci}$ [$ (C_{18:2{\omega}6})_{2}(C_{18:3\;9c,11t,13t})$, 3.6 mol %] and $MDT_{ci}$ [$(C_{18:1{\omega}9})(C_{18:2{\omega}6})(C_{18:3\;9c,11t,13t})$, 3.5 mol %]. Simple TG species of $T_{ci3}$ [$(C_{18:3\;9c,11t,13t})_3]$ was present in a small amount of 1.4 mol %, but other simple TG species were not detected. The TG was also resolved into 11 fractions according to the number of double bond by $Ag^{+}-HPLC$, and the species were mainly occupied by $MT_{ci2}$ [$(C_{18:1{\omega}9})(C_{18:3\;9c,11t,13t})_{2}$, 39.4 mol %] and $S_tT-{ci2}$ [$(C_{18:0})(C_{18:3\;9c,11t,13t})_{2}$, 35.4 mol %] $DT_{ci2}$ species with eight double bonds was also developed faster than $D_2T_{ci}$ one with seven double bonds as indicated in the analysis of TG of the seed oils of T. kirilowii, and $MT_{ci2}$ species with cis, trans, trans-configurated double bond was eluted earlier than $MT_{c2}$ species with cis, trans, cis-configurated double bond. The main components of fatty acid in total TG fraction isolated from the seed oils of of Aleurites fordii were in the following order ; $C_{18:3\;9c,11t,13t}$ (81.2 mol %)> $C_{18:2{\omega}6}$ (8.5 mol %)> $C_{18:1{\omega}9}$ (5.4 mol %)$. With resolution of the TG by RP-HPLC, eight fractions such as $T_{ci3}$, $Dt_{ci2}$, $D_{2}T_{ci}$, $MT_{ci2}$, $PT_{ci2}$ (P; palmitic acid), $PMT_{ci}$, $PDT_{ci}$ and $S_{t}T_{ci2}$ ($S_{t}$; stearic acid) were isolated, respectively. TG species of $T_{ci3}$ [$(C_{18:3\;9c,11t,13t})_{3}$, 54.2 mol %], $DT_{ci2}$ [$(C_{18:2{\omega}6})(C_{18:3\;9c,11t,13t})_{2}$, 15.0 mol %] and $MT_{ci2}$ [$(C_{18:1{\omega}9})(C_{18:3 9c,11t,13t})_{2}$, 14.8 mol %] were present as main species.

Automatic gasometer reading system using selective optical character recognition (관심 문자열 인식 기술을 이용한 가스계량기 자동 검침 시스템)

  • Lee, Kyohyuk;Kim, Taeyeon;Kim, Wooju
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.2
    • /
    • pp.1-25
    • /
    • 2020
  • In this paper, we suggest an application system architecture which provides accurate, fast and efficient automatic gasometer reading function. The system captures gasometer image using mobile device camera, transmits the image to a cloud server on top of private LTE network, and analyzes the image to extract character information of device ID and gas usage amount by selective optical character recognition based on deep learning technology. In general, there are many types of character in an image and optical character recognition technology extracts all character information in an image. But some applications need to ignore non-of-interest types of character and only have to focus on some specific types of characters. For an example of the application, automatic gasometer reading system only need to extract device ID and gas usage amount character information from gasometer images to send bill to users. Non-of-interest character strings, such as device type, manufacturer, manufacturing date, specification and etc., are not valuable information to the application. Thus, the application have to analyze point of interest region and specific types of characters to extract valuable information only. We adopted CNN (Convolutional Neural Network) based object detection and CRNN (Convolutional Recurrent Neural Network) technology for selective optical character recognition which only analyze point of interest region for selective character information extraction. We build up 3 neural networks for the application system. The first is a convolutional neural network which detects point of interest region of gas usage amount and device ID information character strings, the second is another convolutional neural network which transforms spatial information of point of interest region to spatial sequential feature vectors, and the third is bi-directional long short term memory network which converts spatial sequential information to character strings using time-series analysis mapping from feature vectors to character strings. In this research, point of interest character strings are device ID and gas usage amount. Device ID consists of 12 arabic character strings and gas usage amount consists of 4 ~ 5 arabic character strings. All system components are implemented in Amazon Web Service Cloud with Intel Zeon E5-2686 v4 CPU and NVidia TESLA V100 GPU. The system architecture adopts master-lave processing structure for efficient and fast parallel processing coping with about 700,000 requests per day. Mobile device captures gasometer image and transmits to master process in AWS cloud. Master process runs on Intel Zeon CPU and pushes reading request from mobile device to an input queue with FIFO (First In First Out) structure. Slave process consists of 3 types of deep neural networks which conduct character recognition process and runs on NVidia GPU module. Slave process is always polling the input queue to get recognition request. If there are some requests from master process in the input queue, slave process converts the image in the input queue to device ID character string, gas usage amount character string and position information of the strings, returns the information to output queue, and switch to idle mode to poll the input queue. Master process gets final information form the output queue and delivers the information to the mobile device. We used total 27,120 gasometer images for training, validation and testing of 3 types of deep neural network. 22,985 images were used for training and validation, 4,135 images were used for testing. We randomly splitted 22,985 images with 8:2 ratio for training and validation respectively for each training epoch. 4,135 test image were categorized into 5 types (Normal, noise, reflex, scale and slant). Normal data is clean image data, noise means image with noise signal, relfex means image with light reflection in gasometer region, scale means images with small object size due to long-distance capturing and slant means images which is not horizontally flat. Final character string recognition accuracies for device ID and gas usage amount of normal data are 0.960 and 0.864 respectively.

Development and Validation of the Analytical Method for Oxytetracycline in Agricultural Products using QuEChERS and LC-MS/MS (QuEChERS법 및 LC-MS/MS를 이용한 농산물 중 Oxytetracycline의 잔류시험법 개발 및 검증)

  • Cho, Sung Min;Do, Jung-Ah;Lee, Han Sol;Park, Ji-Su;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, ong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • An analytical method was developed for the determination of oxytetracycline in agricultural products using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method by liquid chromatography-tandem mass spectrometry (LC-MS/MS). After the samples were extracted with methanol, the extracts were adjusted to pH 4 by formic acid and sodium chloride was added to remove water. Dispersive solid phase extraction (d-SPE) cleanup was carried out using $MgSO_4$ (anhydrous magnesium sulfate), PSA (primary secondary amine), $C_{18}$ (octadecyl) and GCB (graphitized carbon black). The analytes were quantified and confirmed with LC-MS/MS using ESI (electrospray ionization) in positive ion MRM (multiple reaction monitoring) mode. The matrix-matched calibration curves were constructed using six levels ($0.001{\sim}0.25{\mu}g/mL$) and coefficient of determination ($r^2$) was above 0.99. Recovery results at three concentrations (LOQ, $10{\times}LOQ$, and $50{\times}LOQ$, n=5) were from 80.0 to 108.2% with relative standard deviations (RSDs) less than of 11.4%. For inter-laboratory validation, the average recovery was in the range of 83.5~103.2% and the coefficient of variation (CV) was below 14.1%. All results satisfied the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food Safety Evaluation Department guidelines (2016). The proposed analytical method was accurate, effective and sensitive for oxytetracycline determination in agricultural commodities. This study could be useful for safety management of oxytetracycline residues in agricultural products.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF