• 제목/요약/키워드: Analog signal processing

검색결과 314건 처리시간 0.04초

실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구 (DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER)

  • 박관수;이상래
    • 치과방사선
    • /
    • 제22권2호
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

척수 운동신경원의 기능과 관련된 생존운동신경원 단백질의 역할 (The Role of Survival Motor Neuron Protein associated with Function of Spinal Motor Neuron)

  • 송주영;권영실;남기원;송주민;김동현;김석범;문동철;최진호;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제13권2호
    • /
    • pp.433-444
    • /
    • 2001
  • This review highlights the ontogenesis and the differentiation of motor neuron in spinal cord, and introduce the survival motor neuron(SMN) which is associated with growth and survival of motor neurons. The differentiation of floor plate cells and motor neurons in the vertebrate neural tube appears to be induced by signals from the notochord. This signal is Sonic hedgehog(Shh). The early development of motor neurons involves the inductive action of Shh. The SMN gene is essential for embryonic viability. SMN mRNA is also expressed in virtually all cell types in spinal cord, including large motor neurons. The SMN protein is involved in RNA processing and during early embryonic development is necessary fer cell survival. Two SMN genes are present in 5q 13 in humans: the telomeric gene(SMNt), which is the SMA-determining gene, and the centromeric analog gene(SMNc). The majority of transcripts from the SMNt gene are full length but, major transcripts of the SMNc gene have a high degrees of alternative splicing and tend to have little or no exon 7. The SMN is involved in the RNA processing(the biogenesis of snRNPs and pre-mRNA splicing), the anti-apoptotic effects, and regulating gene expression.

  • PDF

감마선용 고속 피크홀드회로의 개발 (Development of High Speed Peak-hold Circuit for Gamma-ray)

  • 최기성;최규식
    • 한국항행학회논문지
    • /
    • 제20권6호
    • /
    • pp.612-616
    • /
    • 2016
  • 감마선이 존재하는 시설물에서는 발생 즉시 이를 발견하여 처리해야 하며 이와 관련하여 무작위적으로 발생하는 신호를 처리하는 소프트웨어적인 방법을 사용하기도 하나 소프트웨어의 메모리 용량과 처리시간이 커지게 된다. 한편 하드웨어적인 방법으로 신호처리할 수 있는 회로가 일반화되어 있으나 발생 신호의 크기가 미약하고 속도가 고속인 경우에는 이에 대응하지 못한다. 하드웨어적으로 효과적으로 신호처리하려면 값이 매우 비싼 부품과 복잡한 회로를 필요로 한다. 따라서 본 연구에서는 크기는 미약하지만 속도가 고속인 감마선 발생신호에 대해서 하드웨어적으로 간단한 피크홀드 회로를 개발하여 피크 시점에서 ADC가 신호값을 직접 읽어냄으로써 감마선 신호의 피크치를 검출하는 회로를 연구, 개발하였다. 이러한 방법으로 하면 복잡한 소프트웨어 신호처리 방법을 사용하지 않고도 고속 발생신호를 효과적으로 포착할 수 있으므로 감마선의 존재가 농후한 방사능 환경에서 이를 사용하기에 적합하다.

3-D Hetero-Integration Technologies for Multifunctional Convergence Systems

  • 이강욱
    • 마이크로전자및패키징학회지
    • /
    • 제22권2호
    • /
    • pp.11-19
    • /
    • 2015
  • Since CMOS device scaling has stalled, three-dimensional (3-D) integration allows extending Moore's law to ever high density, higher functionality, higher performance, and more diversed materials and devices to be integrated with lower cost. 3-D integration has many benefits such as increased multi-functionality, increased performance, increased data bandwidth, reduced power, small form factor, reduced packaging volume, because it vertically stacks multiple materials, technologies, and functional components such as processor, memory, sensors, logic, analog, and power ICs into one stacked chip. Anticipated applications start with memory, handheld devices, and high-performance computers and especially extend to multifunctional convengence systems such as cloud networking for internet of things, exascale computing for big data server, electrical vehicle system for future automotive, radioactivity safety system, energy harvesting system and, wireless implantable medical system by flexible heterogeneous integrations involving CMOS, MEMS, sensors and photonic circuits. However, heterogeneous integration of different functional devices has many technical challenges owing to various types of size, thickness, and substrate of different functional devices, because they were fabricated by different technologies. This paper describes new 3-D heterogeneous integration technologies of chip self-assembling stacking and 3-D heterogeneous opto-electronics integration, backside TSV fabrication developed by Tohoku University for multifunctional convergence systems. The paper introduce a high speed sensing, highly parallel processing image sensor system comprising a 3-D stacked image sensor with extremely fast signal sensing and processing speed and a 3-D stacked microprocessor with a self-test and self-repair function for autonomous driving assist fabricated by 3-D heterogeneous integration technologies.

블루투스 기반 휴대용 무선 EEG 측정시스템의 개발 (The development of a bluetooth based portable wireless EEG measurement device)

  • 이동훈;이충헌
    • 전기전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.16-23
    • /
    • 2010
  • 최근 뇌 과학 연구에 관심이 높아지면서 두뇌 훈련게임, 교육응용분야 및 BCI(brain Computer Interface)등 여러 분야에서 뇌파를 이용한 장치들이 개발 되고 있다. 본 논문에서는 전두엽 뇌파를 이용해서 간편하고 손쉽게 사용할 수 있는 블루투스 기반 무선 포터블형 뇌파 측정장치를 설계 제작하였다. 10~100 ${\mu}V$의 낮은 진폭을 가진 뇌파를 증폭하여 수V까지 증폭하였고 불필요한 잡음신호와 60 Hz의 전원 노이즈를 제거 하기위하여 저역필터, 고역필터 및 노치 필터를 설계하였다. 또한, 아날로그 뇌파신호를 디지털신호로의 변환과 PC로의 무선 전송을 위해 PIC24F192 마이크로컨트롤러를 사용하였다. AD변환 샘플링율은 1kHz로 하였고, 블루투스방식의 무선전송방식을 이용하여 38,400bps로 PC로 전송하였다. PC로 입력할 때 LabVIEW 프로그램를 이용하여 뇌파신호를 수신하여 모니터링 하였다. 상용 뇌파측정 장치인 Biopac MP100과 개발된 장치에 각각 $1{\mu}V$, 0~200Hz의 동일한 사인파 시뮬레이션 신호를 입력한 후 FFT 변환 후 각각 파워스펙트럼을 분석하여 성능 검증을 비교했다. 상용 Biopac 시스템 MP100과 비교해 본 결과 특히, 30Hz이하의 주파수영역에서 유사한 주파수 응답 특성결과를 얻어 제작된 시스템의 정확도가 우수함을 알 수 있었다.

Conventional simulator를 이용한 Digital image capture system(DICS)의 구축 (The establishment of Digital Image Capture System(DICS) using conventional simulator)

  • 오태성;박종일;변영식;신현교
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.25-32
    • /
    • 2004
  • 목적 : 모의 치료실에서 환자의 정확한 치료 범위 결정을 위해 이용되는 투시영상은 일부 최신의 고가장비에서는 digital로 capture가 가능하나, 일반적인 simulator에서는 analog영상으로 capture를 할 수 없으며 모니터링만 할 뿐이다. 이번 논제에서는 conventional simulator를 이용한 저가의 Digital image capture system의 구현 방식을 소개하고, capture된 digital 영상을 이용한 임상적인. 실용 증례를 소개하고자 한다. 대상 및 방법 : 본원의 conventional simulator(SIMVIEW NT)용 모니터의 비디오 단자(terminal)에 video signal cable을 연결하여 A/D converter에 연결한다. converter jack을 컴퓨터 capture boar에 연결하고 컴퓨터상의 image capture system을 작동시켜서 원하는 image를 capture하거나 동영상을 녹화한다. Esophagus, cervix, breast 환자 등의 capture image를 상용화된 image processing program을 통해 임상적으로 활용한다. 결과 : 경제적으로 저렴하고 용이한 방법으로 Digital image capture system(DICS)의 구축이 가능하였으며 capture된 영상을 이용하여 simulation시에는 보다 정확한 환자 정보와 치료범위를 결정하는데 도움이 되었고, capture된 영상은 data로써 충분한 가치가 있었다. 결론 : 고가의 상용화된 장비를 구입하기 어려운 경우에 이와 같은 방법으로 저가의 system를 구축하게 되면 경제적 효과와 더불어 고가장비와 동등한 영상의 획득 할 수 있으며, 그러한 과정을 통해 얻어진 영상을 이용하여 다른 software program과 연계한다면 더 많은 임상적인 연구를 할 수 있을 것이라 생각된다.

  • PDF

광대역 VLBI 관측을 위한 32Gbps 관측장비의 시험결과 고찰 (A Study on the Test Results of 32 Gbps Observing System for Wideband VLBI Observation)

  • 오세진;염재환;노덕규;정동규;하라다 켄이치;타케자와 코스케
    • 융합신호처리학회논문지
    • /
    • 제18권1호
    • /
    • pp.13-20
    • /
    • 2017
  • 본 논문에서는 KVN의 광대역 VLBI 관측을 위한 백엔드 시스템으로써 도입한 32 Gbps 급 관측장비의 기본적인 시험결과에 대해 고찰한다. 천문학자들은 천체의 초미세 구조를 관측하고자 성능이 우수한 큰 전파망원경을 만들고 싶지만, 많은 돈이 소요된다. 따라서 민감도를 높이기 위해 수신시스템의 성능개선이나 넓은 주파수 대역폭을 관측하는 방법을 도입하고 있다. 이를 위해 본 연구에서는 넓은 관측 주파수 대역폭을 관측하기 위해서는 아날로그 신호를 초고속으로 변환하는 광대역 샘플링 방법과 디지털 필터링을 수행하는 광대역 샘플러를 도입하였다. 광대역 샘플러(OCTAD-K)는 최대 16Gsps-2bit 샘플링을 지원하며, 디지털필터링 기술을 이용하여 다양한 관측대역폭의 관측을 지원한다. 특히 KVN의 4주파수 동시관측시스템과 VERA의 2-beam 관측시스템을 지원할 수 있도록 설계되었다. 그리고 편파관측도 지원할 수 있으며, 관측데이터의 출력의 표준 VDIF 형식을 지원한다. 본 논문에서는 광대역 샘플러를 도입하기 전 수행한 공장검수와 현장시험을 수행한 후 시스템의 성능결과와 문제점 해결 등에 대해 자세히 기술한다.

  • PDF

하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템 (A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL)

  • 장병준;박재형;육종관;문준호;이경중
    • 한국전자파학회논문지
    • /
    • 제20권12호
    • /
    • pp.1325-1332
    • /
    • 2009
  • 본 논문에서는 인체의 호흡 및 심박수 측정을 위해 2.4 GHz에서 동작하는 바이오 레이더 시스템의 소형화 및 성능 개선 방안으로서 하나의 원형 편파 안테나와 PLL 회로를 갖는 시스템을 설계하고 그 측정 결과를 제시 하였다. 제작된 바이오 레이더는 $90^{\circ}$ 하이브리드를 이용하여 원형 편파 특성과 송수신 격리 특성을 갖는 마이크 로스트립 안테나, 저잡음 증폭기, 전력 증폭기, 위상 고정 루프를 갖는 전압 제어 발진기, 직교 복조기 및 아날로그 회로로 구성된다. 특히, 단일 원형 편파 안테나를 소형화하기 위하여 annular-ring 형태의 마이크로스트립 안 테나를 송수신 회로와 적층함으로써, $40\times40mm^2$의 크기로 소형화할 수 있었다. 또한, 누설 송신 신호에 인한 수신부의 위상 잡음의 영향을 최소화하기 위하여 PLL 회로를 채용함으로써, 개선된 신호대 잡음비 성능을 갖도록 하였다. 설계된 바이오 레이더 시스템은 특별한 신호 처리 없이 50 cm 떨어진 사람의 호흡 및 심박수를 측정할 수 있음을 확인하였다.

전동휠체어 압력분포 측정시스템 개발 (Development of pressure measuring system for powered-wheelchair)

  • 길세기;이상철;김태완;황종학;홍응표;한영환;이종실
    • 재활복지공학회논문지
    • /
    • 제7권2호
    • /
    • pp.109-115
    • /
    • 2013
  • 본 논문에서는 전동휠체어용 압력분포 측정시스템을 개발하고, 실제 휠체어 사용자들을 대상으로 동작분석과 연계한 압력분포 변화실험을 통해 유의성을 검증하고자 하였다. 측정시스템은 휠체어 이동방향에 따른 압력분포 변화 측정을 위해 64ch의 시트쿠션 FSR 센서신호 및 좌 우 각 30ch의 팔걸이 FSR 센서신호를 2ch의 좌 우 바퀴형 엔코더 신호와 동시에 12bit, 10Hz의 샘플링 속도로 획득할 수 있도록 개발하였으며, 이 신호들을 USB 인터페이스를 통해 휠체어 뒤쪽에 장착 가능한 노트북PC로 전송 후 실시간으로 화면표시, 저장, 재생을 수행할 수 있는 실시간 신호처리 소프트웨어를 개발하였다. 개발된 측정시스템을 사용한 압력분포 변화 실험은 실제 휠체어 사용자 10인을 대상으로 적외선 마커 기반의 동작분석실에서 3D 동작분석과 연계하여 실시하였다. 실험결과, 휠체어 진행 중 회전구간에서 몸이 회전의 바깥 방향으로 기울어지는 것을 확인할 수 있었으며 실험결과 및 실험 후 인터뷰를 통해 전동휠체어 설계 시 시트의 형태에 대한 개선요구사항을 획득할 수 있었다.

  • PDF

새로운 A급 바이폴라 $CCII{\pm}$와 이를 이용한 출력 전류 제어 가능한 CCII+ 설계 (A Design of Novel Class-A bipolar $CCII{\pm}$ and Its Application to output Current Controllable CCII+)

  • 차형우
    • 대한전자공학회논문지SD
    • /
    • 제48권11호
    • /
    • pp.48-56
    • /
    • 2011
  • 전기적인 조정(tuning) 시스템에 사용하기 위해, 차동출력을 갖는 새로운 A급 $CCII{\pm}$와 이를 이용한 출력 전류 제어가능한 CCII+를 설계하였다. 설계한 $CCII{\pm}$는 종래의 CCII+와 상보적인 교차 전류원으로 구성된다. 또한, 출력 전류 제어가능한 CCII+는 제안한 $CCII{\pm}$와 단일 출력을 갖는 전류 이득 증폭기로 구성된다. 시뮬레이션 결과 $CCII{\pm}$$1.9{\Omega}$의 전류 입력단자의 임피던스와 우수한 전압 및 전류 폴로워 특성을 갖고 있다는 것을 확인하였다. 제안한 CCII+는 $100{\mu}A$에서 10mA의 바이어스 제어 전류 범위에서 10MHz의 3-dB 주파수을 갖고 있으며, 출력 전류 제어 범위는 4-디케이드(decade)이다. CCII+의 전력소비는 ${\pm}2.5V$ 공급전압에서 4.5mW이다.