• Title/Summary/Keyword: Amplitude estimate

Search Result 243, Processing Time 0.031 seconds

On the Chaotic Vibrations of Thin Beams by a Bifurcation Mode (분기 모우드를 활용한 얇은 빔의 혼돈 역학에 관한 연구)

  • 이영섭;주재만;박철희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.121-128
    • /
    • 1995
  • The results are summarized as what follows: 1) The modeling of thin beams, which is a continuous system, into a two DOF system yields satisfactory results for the chaotic vibrations. 2) The concept of "natural forcing function" derived from the eigenfunction of the bifurcation mode is very useful for the natural responses of the system. 3) Among the perturbation techniques, HBM is a good estimate for the response when the geometry of motion is known. 4) It is known that there exist periodic solutions of coupled mode response for somewhat large damping and forcing amplitude, as well as weak damping and forcing. 5) The route-to-chaos related with lateral instability in thin beams is composed of period-doubling and quasiperiodic process and finally follows discontinuous period-doubling process. 6) The chaotic vibrations are verified by using Poincare maps, FFT's, time responses, trajectories in the configuration space, and the very powerful technique Lyapunov characteristics exponents.exponents.

  • PDF

The Relationship between a Wear Depth :and a Decrease of the Contacting Force in the Nuclear Fuel Fretting (핵연료봉 프레팅마멸에서 마멸깊이와 접촉하중 감소사이의 관계)

  • Lee Young-Ho;Kim Hyung-Kyu
    • Tribology and Lubricants
    • /
    • v.22 no.1
    • /
    • pp.8-13
    • /
    • 2006
  • Sliding wear tests have been performed to evaluate the effect of normal load decrease on the wear depth of nuclear fuel rods in room temperature air. The objectives of this study are to quantitatively evaluate the supporting ability of spacer grid springs, to estimate the wear depth by using the contacting force decrease and to compare the wear behavior with increasing test cycles (up to $10^7$) at each spring condition. The result showed that the contacting load decrease depends on the spring shape and the applied slip amplitude. The estimated wear depth is smaller when compared with measured wear depth. Based on the test results, the wear mechanism, the role of wear debris layer and the spring shape effect were discussed.

Regional anomalies of cosmic microwave background power spectrum

  • Ju, Young;Park, Chan-Gyung;Hwang, Jai-Chan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.38.4-39
    • /
    • 2018
  • We analyze the Planck 2015 cosmic microwave background temperature fluctuation data to find any anomaly in the angular power spectra measured for partial regions on the sky. For disks with radius of $20^{\circ}$, $45^{\circ}$ and $90^{\circ}$, which are densely overlapping on the sky, we estimate the power excess and its statistical significance relative to the LambdaCDM expectation for some chosen ranges of angular scales. We also investigate the dipolar asymmetry using the power excess maps obtained for some chosen angular scales, and confirm the previously announced consistent dipole directions. The average dipole amplitude and the inner products of dipoles have been measured from the power excess maps at different angular scales. We conclude that although dipole directions are consistent the measured amplitudes are not statistically significant compared to the LambdaCDM model prediction.

  • PDF

Crack Growth Behavior of Tensile Overload for Small Load Amplitude (하중진폭이 작은 인장과대 하중의 균열성장 거동)

  • 유헌일
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.2
    • /
    • pp.54-61
    • /
    • 1998
  • This paper examines the crack growth behavior of 7075-T651 aluminum alloy for small tensile overload under high-low block loading condition. The cantilever beam type specimen with a chevron notch is used in this study. The crack growth and closure are investigated by compliance method. The applied initial stress ratios are R=-0.5 R=0.0 and R=0.25 Crack length, effective stress intensity factor range, ratio of effective stress intensity factor range and crack growth rate etc, are inspected with fracture mechanics estimate.

  • PDF

Noise Reduction Characteristics of A Modulated Orthogonal Sequence Under Weak-Signal Communication Channels (약한 신호 통신로에서 한 변조 직교수열의 잡음 줄임 특성)

  • 박성일;김윤희;김홍길;송익호;이성로
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.7
    • /
    • pp.1824-1830
    • /
    • 1998
  • In this paper, we investigate a noise reduction scheme, based on the inherent characteristic of an orthogonal sequence. The modulated orthogonal code generates sequences of length $N^{2}$ from N information symbols. Using the amplitudes of the received symbols, we first estimate the location of the smallest amplitude noise. Then the noise is reduced by the suggested system. The performance of the scheme is confirmed by computer simulation results.

  • PDF

A study on the Estimation Technique of Frequency in the Power System using Digital Signal Processing (디지털 신호처리기법을 이용한 전력계통 주파수 추정 기법에 관한 연구)

  • Nam, S.B.;Park, C.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.175-177
    • /
    • 2001
  • Frequency and phasor are the most important quantities in power system operation. Frequency reflects the dynamic energy balance between load and generating power. To estimate of power system frequency, an accurate digital tracking algorithm by using phasor angle difference is presented. For an evaluation of the proposed technique, simulations by EMTP have been performed. Test results were showed the algorithm's accuracy under the effect of noise and changes in frequency and amplitude on the input signal.

  • PDF

Suppression of Output Distortion in a Gyroscope using Fiber Amplifier/Source by Tracking of Optimum Modulation Amplitude

  • Park, Hee-Gap
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.80-85
    • /
    • 1999
  • We propose and demonstrate a new scheme for suppression of output distortion in an open-loop gyroscope employing an erbium-doped fiber amplifier/source (FAS). In addition to the main modulation for the rotation rate measurement, a small auxiliary modulation at a different frequency is used to extract an error signal, which is necessary for keeping the quasi-dc component of the feedback signal power at a constant level for varying rotation rate. By active tracking of the optimum modulation condition using this two-frequency modulation scheme, we obtain stable gyro output with suppressed distortion as well as stable FAS characteristics. We also calculate the distortion in the gyro response due to the feedback effect, from which we estimate the FAS gyro output distortion due to the residual ac feedback effect when the dc feedback effect is removed by the proposed scheme. The measured residual deviation agrees reasonably with the estimation.

In Vivo Quantitative Analysis of PKA Subunit Interaction and cAMP Level by Dual Color Fluorescence Cross Correlation Spectroscopy

  • Park, Hyungju;Pack, Changi;Kinjo, Masataka;Kaang, Bong-Kiun
    • Molecules and Cells
    • /
    • v.26 no.1
    • /
    • pp.87-92
    • /
    • 2008
  • We employed dual color Fluorescence Cross Correlation Spectroscopy (FCCS) to measure the interaction between PKA regulatory (RII) and catalytic subunits (CAT) in living cells. Elevation of intracellular cAMP with forskolin decreased the cross-correlation amplitude between RFP-fused RII (RII -mRFP) and GFP-fused CAT (CAT-EGFP) by 50%, indicating that cAMP elevation leads to dissociation of RII-CAT complexes. Moreover, diffusion coefficient analysis showed that the diffusion rate of CAT-EGFP was significantly increased, suggesting that the decreased RII-CAT association caused by cAMP generated free CAT subunits. Our study demonstrates that in vivo FCCS measurements and their quantitative analysis permit one not only to directly quantify protein-protein interactions but also to estimate changes in the intracellular cAMP concentration.

Estimation of Natural Frequency of Reinforced Concrete Slab (철근콘크리트 슬래브의 고유진동수 추정)

  • Woo, Woon-Taek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.4
    • /
    • pp.219-223
    • /
    • 2000
  • The evaluation of habitability to building vibration is conducted by the values of natural frequency, amplitude displacement, damping ratio. These values can be obtained from test or analytical results. Data acquisition through test may be possible in existing building, however, to estimate the serviceability of the building, it is necessary to evaluate those values at the stage of design. The natural frequency is important and basic factor for the evaluation of the serviceability. Calculation method of the effective stiffness in RC slab is proposed. To prove the efficiency of the proposed method, sample results of the analysis and the test are compared. These results proved that the effective width proposed to calculate the effective stiffness is proper to evaluate the natural frequency.

  • PDF

The Electrochemical Study of the Concrete Reinforcement Corrosion (콘크리트내부의 철근부식에 관한 전기화학적연구)

  • 강태혁;조원일;신치범;김은겸;주재백;윤경석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.213-217
    • /
    • 1996
  • The electrochemical methods of early detection and analysis of corrosion related deterioration in concrete reinforcement structures are very useful techniques. The generally using procedure for corrosion monitoring of reinforced structures employs a method of half-cell potential measurement. Whilst the technique has provided a useful means of delineating areas of high or low corrosion risk, there are difficulties in its use and interpretation, particularly when assessing corrosion rates of reinforcement. The aim of this study is to describe the AC-impedance method being employed to monitor and assess corrosion rates, to estimate corrosion mechanism of reinfrocement in laboratory conditions. The AC-impedance monitoring technique applies a small amplitude(20mV) AC signal to embedded steel in concrete and reference electrode (Cu/$CuSo_4$). We obtained over a wide frequency range(10MHz~1mHz) to produce a complex plane plot or Nyquist plot.

  • PDF