• 제목/요약/키워드: Amplitude Ratio

검색결과 960건 처리시간 0.028초

큰 진폭의 반복하중 조건에서 R-ratio에 따른 J-적분 정량화 (Quantification of R-ratio effect on J-integral under large-amplitude cyclic loading condition)

  • 남현석;김윤재;김진원
    • 한국압력기기공학회 논문집
    • /
    • 제12권2호
    • /
    • pp.34-39
    • /
    • 2016
  • This paper presents a method to quantify R-ratio effect on J-integral under large-amplitude cyclic loading condition. Generally, monotonic tearing resistance curves are used to assess stability of cracked nuclear piping under seismic loading. However, it is well known that fracture toughness decrease at cyclic loading condition, according to R-ratio. For this reason, it is important to quantify the J-R curves under cyclic loading condition. To quantify the R-ratio effect, correction method which was proposed by Tranchand is considered. This method considers crack opening area in order to calculate modified J-integral. This method leads to an increase of fracture toughness. At R=-0.5 case, this method is good agreement with monotonic J-R curves. However, results show that this method has a limit to apply a large R-ratio case.

2024-T3 A1 합금의 이방성이 피로균열진전속도와 정류거동에 미치는 영향 (Effect of Anisotropy on Fatigue Crack Propagation Rate and Arrest Behavior with 2024-T3 Alumunum Alloy)

  • 오세욱;김태형;오정종
    • 한국해양공학회지
    • /
    • 제7권1호
    • /
    • pp.124-132
    • /
    • 1993
  • In order to examine the effect of anisotropy and stress ratio on fatigue crack propagation rate and opening-closing behavior and also arrest behavior by single tension peak overload, the fatigue tests of constant amplitude atress and single tension peak overload adding to cycle of constant amplitude were carried out in stress ratio of -0.4, -0.2, and 0.4 with materials of T-L and L-T directions in 2024-T3 aluminum alloy plate. Crack opening-closing begavior were measured by the compliance method using COD gage and strain gage. In case of the crack opening-closing behavior was measured by strain gage, the effect of stress ratio is unchangeable. But in the case of COD gage, that is remarkably decreased. Fictitious effective stress intensity factor(U sub(f)) and effective stress intensity factor ratio(U) in L-T direction was higher than those in T-L direction and also threshold arrest overload ratio incrased as stress ratio decreased and that of T-L direction was higher than that in L-T direction.

  • PDF

비침습적 혈압 측정 시스템 구현에 관한 연구 (A Study on Implemetation of Non-invasive Blood Pressure)

  • 노영아;이종수;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.451-454
    • /
    • 2000
  • 혈압을 측정하는 방법에는 침습적(Invasive)인 방법과 비침습적(Non-invasive)인 방법이 있는데 침습적인 방법에 의한 혈압측정의 경우 정확한 값을 얻는 반면에 그 사용법이 복잡하고 환자에게 불편하므로 중환자의 경우를 제외한 경우 대부분 비침습적인 방법에 의해 혈압을 측정한다. 현재 전자 혈압계의 경우 대부분이 오실로메트릭(Oscillometric) 방법을 사용하여 기본적인 시스템을 구성하고 여기에 여러 가지 알고리즘을 부가적으로 적용하고 있다. 본 연구에서 이러한 혈압 측정 시스템을 개발하기 위해 커프(Cuff)의 압력을 제어, 측정하고 측정된 데이터를 필터링하여 혈압을 측정할 수 있도록 알고리즘을 구성하였다. 통신방식으로는 개발된 시스템의 모든 기능이 개인용 컴퓨터(Personal Computer)와의 통신을 통해 이루어지도록 구성되어져 있으며, 사용된 통신방식은 비동기 직렬 통신 방식(RS-232)인 패킷방식을 사용하였고 솔레노이드(Solenoid) 밸브를 이용한 자동 또는 급속 배기 방법을 이용하여 커프의 압력을 감압(Deflation)하였다. 혈압측정 알고리즘은 기본적인 오실로메트릭 방법과 최대 진폭 알고리즘(Maximum Amplitude Algorithm)을 사용하였다. 최대진폭 알고리즘에서는 측정된 오실레이션(Oscillation)중 최고의 진폭을 가지는 오실레이션 같은 오차의 원인이 되는 연령이나 체중, 팔의 두께에 따라 다양하게 나타난다. 본 연구에서는 오실레이션의 간에 획일적인 비율을 적용하지 않고 여러 가지 요인들에 대한 가변적인 특정 비율(Characteristic Ratio)반영하여 보다 정확한 최고혈압(Systolic Blood Pressure), 최저혈압(Diastolic Blood Pressure), 평균혈압(Mean Blood Pressure)의 값을 구하는 연구를 하였다. 최고진폭 알고리즘에서 가변적인 특성비율의 적용은 혈압간의 오차를 줄일 수 있을것으로 기대된다.

  • PDF

반복하중을 받는 강판의 강도 및 변형특성 (Strength and Deformation Behavior of Steel Plates under Cyclic Loadinga)

  • 황원섭;윤형석;전승권
    • 한국강구조학회 논문집
    • /
    • 제13권2호
    • /
    • pp.143-152
    • /
    • 2001
  • 본 연구에서는 정적 및 반복하중을 받는 강판의 거동특성에 관하여 검토하였다. 강판의 강도에 관한 설계변수로서는 초지처짐과 형상비, 판의 폭-두께비등을 들 수 있으며, FEM해석을 통하여 이상의 설계변수에 관한 영향에 관하여 검토하였다. 정적 압축하중이 작용하는 판의 강도는 형상비가 1.0이하인 경우에는 형상비 변화에 따른 영향이 거의 나타나지 않았으며, 반복하중을 받는 판의 경우 폭-두께비와 변위 진폭의 크기가 강도에 크게 영향을 미치고 있음을 확인하였다. 이러한 해석결과를 기초로 본 연구에서는 반복재하에 의한 강도감소 특성을 고려한 강도곡선식을 제안하였으며, 또한 폭-두께비와 변위 진폭에 따른 판의 변형성능에 관해서 검토하였다

  • PDF

반경비 및 각속도의 변화에 따른 Taylor 유동에 관한 연구 (A STUDY ON TAYLOR FLOW ACCORDING TO RADIUS RATION AND ANGULAR VELOCITY)

  • 배강열;김형범;정희택
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2007년도 추계 학술대회논문집
    • /
    • pp.127-133
    • /
    • 2007
  • This paper represents the numerical study on Taylor flow according to the radius ratio and the angular velocity for flow between tow cylinder. The numerical model is consisted of two cylinder which inner cylinder is rotating and outer cylinder is fix, and the axial direction is used the cyclic condition because of the length for axial direction is assumed infinite. The diameter of inner cylinder is assumed 86.8 mm, the numerical parameters are angular velocity and radius ratio. The numerical method is compared with the experimental results by Wereley, and the results are very good agreement. The critical Taylor number is calculated by theoretical and numerical analysis, and the results is showed the difference about ${\pm}10\;%$. As $Re/Re_c$ is increased, Taylor vortex is changed to wavy vortex, and then the wave number for azimuthal direction is increased. Azimuthal wave according to the radius ratio is showed high amplitude and low frequence in case of small radius ratio, and is showed low amplitude and high frequence in case of large radius ratio.

  • PDF

Study of Optical Transmission Performance in IP-over-WDM Networks Based on FSK/ASK Combined Modulation Format

  • Xiangjun, Xin;Andre, Paulo Sergio de Brito;Teixeira, Antonio Luis Jesus;Monteiro, Paulo P.;Rocha, Jose R. F. da
    • ETRI Journal
    • /
    • 제27권3호
    • /
    • pp.267-272
    • /
    • 2005
  • The transmission performance of optical labeling based on a combined frequency shift keying/amplitude shift keying (FSK/ASK) format is studied by numerical simulation. The simulation demonstrates that the bit-error ratio (BER) characteristic of an ASK signal is limited by the extinction ratio, received optical power, and dispersion, simultaneously. However, an FSK signal is mainly limited by the extinction ratio (ER) and received optical power when the peak spectrum, which is used to detect the FSK signal, is relatively narrow.

  • PDF

조화운동하는 기반상에서 작동하는 비선형 동흡진기의 동특성에 관한 연구 (A study on the dynamic characteristics of non-linear dynamic vibration absorber excited by harmonic ground motion)

  • 김광식;안찬우
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.131-136
    • /
    • 1988
  • 본 연구에서는 기반의 주기변위를 받는 주진동계에 비선형스프링과 선형 감쇠를 갖는 비선형동흡진기가 부착된 진동계의 운동방정식을 유도하여 조화바란스법 으로 지면에 대한 주진동계의 상대진폭의 진폭비를 산출하고 안정성해석을 하였으며, 비선형성의 영향과 스프링의 경.연성에 따르는 특성을 규명하였다.

휴대용 심전도 측정장치를 위한 실시간 QRS-complex 검출 알고리즘 개발 (Development of Real-time QRS-complex Detection Algorithm for Portable ECG Measurement Device)

  • 안휘;심형진;박재순;임종태;정연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권4호
    • /
    • pp.280-289
    • /
    • 2022
  • In this paper, we present a QRS-complex detection algorithm to calculate an accurate heartbeat and clearly recognize irregular rhythm from ECG signals. The conventional Pan-Tompkins algorithm brings false QRS detection in the derivative when QRS and noise signals have similar instant variation. The proposed algorithm uses amplitude differences in 7 adjacent samples to detect QRS-complex which has the highest amplitude variation. The calculated amplitude is cubed to dominate QRS-complex and the moving average method is applied to diminish the noise signal's amplitude. Finally, a decision rule with a threshold value is applied to detect accurate QRS-complex. The calculated signals with Pan-Tompkins and proposed algorithms were compared by signal-to-noise ratio to evaluate the noise reduction degree. QRS-complex detection performance was confirmed by sensitivity and the positive predictive value(PPV). Normal ECG, muscle noise ECG, PVC, and atrial fibrillation signals were achieved which were measured from an ECG simulator. The signal-to-noise ratio difference between Pan-Tompkins and the proposed algorithm were 8.1, 8.5, 9.6, and 4.7, respectively. All ratio of the proposed algorithm is higher than the Pan-Tompkins values. It indicates that the proposed algorithm is more robust to noise than the Pan-Tompkins algorithm. The Pan-Tompkins algorithm and the proposed algorithm showed similar sensitivity and PPV at most waveforms. However, with a noisy atrial fibrillation signal, the PPV for QRS-complex has different values, 42% for the Pan-Tompkins algorithm and 100% for the proposed algorithm. It means that the proposed algorithm has superiority for QRS-complex detection in a noisy environment.

관상동맥질환을 진단하기 위한 R파와 T파의 크기에 대한 연구 (R and T Wave Amplitude as a Parameter to Detect Coronary Artery Disease)

  • 임현균;유권규;김진목;김인선;강찬석;박용기
    • Progress in Superconductivity
    • /
    • 제10권1호
    • /
    • pp.6-11
    • /
    • 2008
  • Multi-channel magnetocardiography (MCG) has been proposed to detect ischemic heart disease because its sensitivity is quite high comparing with other conventional diagnostic tools. Especially, current map and magnetic field map of MCG provide crucial information on whether myocardiac muscles maintain the normal conduction pathway. In addition, MCG parameters derived from repolarization are useful to detect coronary artery disease. Recently, there was a study reporting that R- and T- wave amplitude are highly correlated with ischemic heart disease. In this study, we studied R- and T-wave amplitude and their ratio as well as MCG parameters. MCG data from 20 young, 20 age-matched controls, and 20 myocardial infarction (MI) patients were analyzed. As a result, MCG parameters showed significant change in MI patients comparing to those of controls. R- and T-wave amplitude of MI patients showed a feature of severe ischemic heart disease even though it was difficult to find consistent values. Further study is needed to reveal the relations between small T-wave amplitude and coronary artery disease.

  • PDF

High aspect ratio wrinkled patterns on polymers by glancing angle deposition

  • Ko, Tae-Jun;Ahmed, Sk. Faruque;Lee, Kwang-Ryeol;Oh, Kyu-Hwan;Moon, Myoung-Woon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.335-335
    • /
    • 2011
  • Instability of a thin film attached to a compliant substrate often leads to emergence of exquisite wrinkle patterns with length scales that depend on the system geometry and applied stresses. However, the patterns that are created using the current techniques in polymer surface engineering, generally have low aspect ratio of undulation amplitude to wavelength, thus, limiting their application. Here, we present a novel and effective method that enables us to create wrinkles with a desired wavelength and high aspect ratio of amplitude over wavelength as large as to 2.5:1. First, we create buckle patterns with high aspect ratio of amplitude to wavelength by deposition of an amorphous carbon film on a surface of a soft polymer poly(dimethylsiloxane) (PDMS). Amorphous carbon films are used as a protective layer in structural systems and biomedical components, due to their low friction coefficient, strong wear resistance against, and high elastic modulus and hardness. The deposited carbon layer is generally under high residual compressive stresses (~1 GPa), making it susceptible to buckle delamination on a hard substrate (e.g. silicon or glass) and to wrinkle on a flexible or soft substrate. Then, we employ glancing angle deposition (GLAD) for deposition of a high aspect ratio patterns with amorphous carbon coating on a PDMS surface. Using this method, pattern amplitudes of several nm to submicron size can be achieved by varying the carbon deposition time, allowing us to harness patterned polymers substrates for variety of application. Specifically, we demonstrate a potential application of the high aspect wrinkles for changing the surface structures with low surface energy materials of amorphous carbon coatings, increasing the water wettability.

  • PDF