• Title/Summary/Keyword: Amount of solar radiation

Search Result 198, Processing Time 0.022 seconds

Performance Analysis of Photovoltaic Power Generator by Usage Battery Charge (축전지 사용 유무에 따른 태양광발전기의 성능 분석)

  • Yun, Sung Wook;Choi, Man Kwon;Kim, Hyeon Tae;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.220-227
    • /
    • 2013
  • This study examined the electric power quantity derived from solar radiation after installing a photovoltaic power generation system on the rooftop of building adjacent to a greenhouse with a view to reducing the operating expenses of the greenhouse by securing electric energy required to run it. Results of the study can be summed up as follows: The maximum, mean, and minimum solar radiation on the horizontal plane was $26.1MJ{\cdot}m^{-2}$, $14,0MJ{\cdot}m^{-2}$, and $0.6MJ{\cdot}m^{-2}$, respectively and individual the daily electric energy generated was about 6.1 kWh, 3.7 kWh, and 0.01 kWh. The cumulative total amounts of solar radiation and electric energy was about $4,378.2MJ{\cdot}m^{-2}$ and 1,163.2 kWh, respectively. Maximum, mean and minimum cumulative electric energy consumed through each load respectively was 4.5 kWh, 2.4 kWh, and 0.0 kWh and the cumulative electric energy were 739.2 kWh, which accounted for about 63.5% of generated power. In case of the mean amount of power consumption of the system used for this study, the small capacity of heater and the short operating hours meant there was enough power; while big capacity of heater led to a shortage, and if the array surface temperature increased relatively, the energy became proportionate to solar radiation and generated power does not increase. The correlation coefficient between the two factors was 0.851, which indicates a high correlation coefficient.

Improvement of generation capacity per unit site area by the optimization of photovoltaic array (태양광어레이 최적화에 의한 단위 부지면적당 발전량 개선)

  • Kim, Eui Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.109.2-109.2
    • /
    • 2011
  • A photovoltaic system is getting the spotlight for a environment-friendly energy source. But its location is limited because a lot of land is necessary for photovoltaic arrays. Nevertheless, its dissemination is rapidly increasing more than 40 % every year and exceeded about 400 MW in 2009. The radical growth of a photovoltaic system aggravated a lack of sites, so that forests and farmland were destroyed. It is demanded to make use of a vacant lot or little piece of land for the way to solve the lack of sites and improve the location requirements for a photovoltaic system. General photovoltaic arrays are consist of a single layer structure and needs enough separation distances to maximize the amount of solar radiation and to eliminate influences by the shadow of other arrays. So that a large amount of land is required for the site. The solar cell arrays with long separation distances can not be placed in a small vacant lot and its site application efficiency is low. This study optimized photovoltaic arrays as multilayered structure with movable sleeves for the efficient photovoltaic in a small site. The existing photovoltaic arrays with a single layer structure were fixed or tracking systems. In this experimental equipment, photovoltaic arrays attached to the multilayers have rectilinear movement and rotary motion using sleeves. Therefore, shadow influences were removed and the generation capacity was improved. On the simulation result, generation increased by about 30% in the same site considering shadow influences and so on.

  • PDF

A Quick MPPT Strategy of Rooftop Photovoltaic Generation System for the Electric Vehicle (전기자동차를 위한 루프형 태양광 발전 시스템의 속응 최대 전력점 추종기법)

  • Kang, Kyoungpil;Cho, Younghoon;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.325-326
    • /
    • 2014
  • This paper is research about the Maximum Power Point Tracking following algorism of solar power system attached small electric car. In this paper, we investigate P&O MPPT and Incremental Conduction MPPT among existing MPPT following algorism. And by changing them, the better algorism is proposed being able to follow Maximum Power Point rapidly as amount of solar radiation changes applied to the Solar Energy Generation System.

  • PDF

Effect of Solar Irradiances on Growth and Pigmentation of Antarctic Red Algae, Kallymenia antarctica and Palmaria decipiens

  • Han, Tae-Jun;Han, Young-Seok;Lee, Min-Soo;Park, Jin-Hee;Cho, Man-Gi;Koo, Jae-Gun;Kang, Sung-Ho
    • Ocean and Polar Research
    • /
    • v.25 no.4
    • /
    • pp.427-435
    • /
    • 2003
  • Growth and pigment responses to different levels of solar radiation with or without ultraviolet (UV)-B component $({\lambda}=280-315nm)$ were investigated in Antarctic rhodophytes, Kallymenia antarctica and Palmaria decipiens, collected around King George Island during the summer of 2000. In K. antarctica specific growth rate, based on thallus area or fresh weight, decreased with increasing solar irradiances while P. decipiens were relatively insensitive to the effects of light. It is noticeable that the presence or absence of UV-B had no significant effect on growth for either species. However, K. antarctica showed a more pronounced reduction in chlorophyll (Chl a) concentrations at higher irradiances in the presence of UV-B. In P. decipiens, Chl a concentrations did not differ despite radiation level fluctuations being lower albeit than initial measurements. Thallus thickness was greater in K. antarctica than in P. decipiens. There were higher relative amounts of UV-absorbing pigments (UVAPs) in P. decipiens than in K, antarctica. The single absorbance peak obtained from the methanol extracts was resolved into three (316,332 and 346nm) in K. antarctica and four peaks (315,326,333 and 349 nm) in Palmaria as a result of the fourth-derivative. After 7 days exposure to solar radiation, the amount of UVAPs in K. antarctica was significantly reduced to a similar degree at all light levels, whereas that of P. decipiens remained unchanged except at 5% of surface irradiance. High performance liquid chromatography (HPLC) analysis of purified extracts indicated that P. decipiens possesses porphyra-334 in addition to three other mycosporine-like anlino acids (MAAs; asterina-330, palythine, shinorine), which are commonly present in K. antarctica. Significantly lower tolerance of K. antarctica to high levels of solar radiation may be connected with its usual absence in the eulittoral, while the active growth and elastic pigment responses of P. decipiens over a wide range of solar irradiance levels up to full sunlight seems to correspond well with its wide vertical distribution from rock pools down to 25-30m.

Measurement of Mass Flow of Water in the Stem of Musk Melon by Sap Flow Gauge (열목지 경유센서에 의한 멜론 경유양의 측정)

  • 강곡명;양원모
    • Journal of Bio-Environment Control
    • /
    • v.7 no.3
    • /
    • pp.268-274
    • /
    • 1998
  • The mass flow of water in the stem of melon measured by Sap Flow Gauge was compared with the actual flow calculated by the difference between supply and drainage nutrient water to investigate the possibility and accuracy of estimation of melon's transpiration in rockwool culture. The Sap Flow Gauge which was made with copper-constantan theromocouple and nichrome fiber by our research team, was attached to the 3rd node of melon. The outdoor temperature, room temperature, solar radiation and relative humidity were continually measured. The amount of supply and drainage nutrient water were simultaneously measured for calculation of practical consumption of nutrient water to compare with mass flow of sap. The measuring errors of Sap Flow Gauge were 0.3 to 31.8%, which were small at solar radiation of 20MJ.m$^{2}$.d$^{-1}$ . The mass flow of water was lower for the measured value by Sap Flow Gauge than the actual value at higher solar intensity, however it was higher at lower solar intensity The variation of error rate of each Sap Flow Gauge was 0.1 to 13.0%. The measuring error with Sap Flow Gauge was negatively related with solar intensity and temperature. Therefore, to measure more exactly the mass flow of sap for estimation of melon's transpiration, the compensation factor must be calculated.

  • PDF

An Experimental Study on Relationship Between Temperature Change and Generation Performance of a-Si BIPV Window System (박막 BIPV창의 온도변화와 발전성능 상관관계에 관한 실측연구)

  • Kim, Bit-Na;Yoon, Jong-Ho;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.179-184
    • /
    • 2012
  • This research on building Integrated Photovoltaic System replacing windows and doors with amorphous silicon thin film PV windows and doors installing same exact mount on Mock-up. The windows and doors should be installed in different angle and bearing so that we can analyse the amount of electricity from them. The objective of the research is to evaluate and investigate the relationship between factors(intensity of solar radiation, PV window surface temperature, incidence angle, and sky conditions) that affects performance of PV window and performance. The range and method of this research is to establish monitoring system and analysis the data from the monitoring system to evaluate the performance of PV windows that have thin film of solar battery. We should evaluate the insolation according to the position of PV window, output, and surface temperature according to months and seasons so that we can figure out the relationship between these. And we should investigate the relationship between performance and efficiency according to incidence angle and sky condition so that we can figure out the correlation between factors and performance.

Assessment of Earth Remote Sensing Microsatellite Power Subsystem Capability during Detumbling and Nominal Modes

  • Zahran M.;Okasha M.;Ivanova Galina A.
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.18-28
    • /
    • 2006
  • The Electric Power Subsystem (EPS) is one of the most critical systems on any satellite because nearly every subsystem requires power. This makes the choice of power systems the most important task facing satellite designers. The main purpose of the Satellite EPS is to provide continuous, regulated and conditioned power to all the satellite subsystems. It has to withstand radiation, thermal cycling and vacuums in hostile space environments, as well as subsystem degradation over time. The EPS power characteristics are determined by both the parameters of the system itself and by the satellite orbit. After satellite separation from the launch vehicle (LV) to its orbit, in almost all situations, the satellite subsystems (attitude determination and control, communication and onboard computer and data handling (OBC&DH)), take their needed power from a storage battery (SB) and solar arrays (SA) besides the consumed power in the EPS management device. At this point (separation point, detumbling mode), the satellite's angular motion is high and the orientation of the solar arrays, with respect to the Sun, will change in a non-uniform way, so the amount of power generated by the solar arrays will be affected. The objective of this research is to select satellite EPS component types, to estimate solar array illumination parameters and to determine the efficiency of solar arrays during both detumbling and normal operation modes.

Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector (태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구)

  • Woo, Jong-Soo;Choi, Kwang-Hwan;Yoon, Jeong-In
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

Yearly Variation and Influencing Factors of Ozone Concentration in the Ambient Air of Seoul (서울시 대기중 오존오염도의 연도별 변화와 그 영향인자 분석: 광화문 지역을 중심으로)

  • Lee, Ki-Won;Kwon, Sook-Pyo;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.107-115
    • /
    • 1993
  • This study was carried out to find the characteristics of surface ozone concentration data obtained during 1988-1991 by the Korea Ministry of Environment. Seasonal data (spring, summer, autumn and winter) wre obtained in May, August, November and February respectively at Kwanghwamun in Seoul. The pollutants analyzed in this study are $SO_2, TSP, CO, NO, NO_2 and NO_2/NO$. Atmospheric factors such as solar radiation, wind speed, relative humidity, cloud amount and atmospheric temperature are also analyzed. The influence of pollutants and atmospheric factors that affect ozone concentration were analyzed by statistical method. The results are summarized as follows : 1. The ozone concentration varied seasonally. The maximum values were 23 ppb in spring, 33 ppb in summer, 16 ppb in autumn and 13 ppb in winter. So the seasonal ozone value was highest in Summer. 2. Te diurnal concentration of ozone was highest during 2-4 P. M. and was very low in the morning and evening. 3. The maximal correlation coefficients of each season between ozone concentration and the influencing pollutants or atmospheric factors asr as follows ; a. spring, r = 0.44(solar radiation) b. summer, r = -0.59(relative humidity) c. autumn, r = -0.55(relative humidity) d. winter, r = -0.58($NO_2$) 4. The major factor affecting the ozone concentration in spring was solar radiation, Relative humidity was the first affecting factor in summer, autumn and $NO_2$ concentration was dominant in winter.

  • PDF

Effect of Greenhouse Cooling Method on the Growth and Yield of the Tomato cv. Momotaro in Warm Season (고온기 유리온실의 냉방방법이 토마토 생육 및 수량에 미치는 영향)

  • 이재한;박동금;권준국;엄영철;최영하
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.60-64
    • /
    • 2000
  • This study was conducted to investigate effects of cooling methods on the growth and yield of tomato cv. momotaro in the glasshouse for four years from 1996 to 1999. Cooling methods were fan, fan and fogging, fan and shading(temp. control), fan and shading(radiation control), fan and shading (temp. control) with fogging. Fan, Fogging and Shading(temp. control) were operated automatically when air temperature was over 3$0^{\circ}C$. Amount of fogging was 500m1/min/100m$^2$and Droplets in a fog were 50 microns or smaller. Shading(radiation control) was operated automatically when solar radiation was over 500W/m$^2$. The growth and yield were the least in fan and shading(temp. control) method due to lack of light Intensity. Fogging method must be reconsidered for expensive equipment and maintenance expenses. As the matter stands, It is suggested to be the most considerable cooling method to increase ventilation rate with fan or use fan and shading(radiation control).

  • PDF