• Title/Summary/Keyword: Amount of Heat

Search Result 2,362, Processing Time 0.029 seconds

METAL SURFACE CHANGES BY HEAT TREATMENT OF Ni-Cr ALLOYS (열처리에 의한 도재용 Ni-Cr합금 표면의 변화에 관한 연구)

  • Kim, Young-Han;Lee, Sun-Hyung;Yang, Jae-Ho;Jung, Heon-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.219-248
    • /
    • 1989
  • The purposes of this study were to analyze the microstructural and compositional changes of metal surfaces following different conditions of preoxidizing heat treatment, to investigate the composition of metal oxides, and to evaluate the effect of preoxidation and removal of surface oxides on microstructure and diffusion profiles. The techniques of EDAX (energy-dispersive analysis of x-ray), ESCA (electron spectroscopy for chemical analysis), and EPMA (electron probe micro analysis) were used, along with SEM (scanning electron microscopy). The obtained results were as follows : 1. A surface of the specimen became rough and the amount of the metal oxides increased with increasing the heat treatment time and temperature and the partial pressure of oxygen. 2. At an air pressure of 28' vacuum, the higher the temperature and the longer the time of preoxidation, the higher Ni concentration was detected. 3. Cr concentration in the specimen heat treated with air was higher than that of with vacuum. 4. The oxides in the specimens were mainly composed of Ni and Cr oxides. On the globular growth particles, significant rises in Al concentration of Rexillium III and Ti concentration of Verabond were noted. 5. Atomic diffusion occurred at the ceramic-metal interface, furthermore the amount of the flux was increased with preoxidation heat treatment.

  • PDF

Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat (저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구)

  • Cho, Soo-Yong;Cho, Chong-Hyun
    • New & Renewable Energy
    • /
    • v.10 no.4
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.

Microstructure and Strength Characteristic of 9Cr Ferritic Heat-resistant Steel Applied to the Power Plants (발전플렌트용 9Cr 페라이트 내열강의 미세조직과 강도특성)

  • Kang, C.Y.;Lee, J.M.;Lee, G.H.;Lee, M.Y.;Sung, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.1
    • /
    • pp.27-34
    • /
    • 2000
  • This present study were investigated effect of Ni contents on the microstructure and strength characteristic in 9Cr ferritic heat-resistant steel added 1.7%W in place of Mo in order to restrain laves phase formation. The result obtained from this study are as follow. Volume fraction, number of particles per unite area and particle size of carbide decreased with increase of Ni contents. Other side, carbides of $M_{23}C_6$ type was mainly precipitated in this steel, but laves phases could not precipitated in spite of increasing of aging time. With increase of tempering temperature, hardness was increased, and maximum value was showed around 873k by secondary hardening due to precipitation of $W_2C$ type carbide and then, was decreased. Tensile and yield strength due to decrease precipitation amount of carbide and number of particles per unite area was decreased, but elongation and impact value was increased. In case of aged specimen after tempering than tempered specimen, strength was higher and elongation was lower due to increasing of precipitated amount of carbide and number of particles per unite area.

  • PDF

Effect of Additional Electrical Current on Adhesion Strength between Copper and Polyimide Films (인가 전류가 구리 도금 피막과 폴리이미드 필름의 접합력에 미치는 영향)

  • Lee, Jang-Hun;Han, Yoonsung;Lee, Ho-Nyun;Hur, Jin-Young;Lee, Hong Kee
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • The effect of the additionally applied electrical current on the adhesion strength between electroless Cu and polyimide films was investigated. Peel tests were performed after applying electrical current within the range from 0.1 to 100 mA for the duration from 1 to 30 minutes. Sample with more than 1 mA of additional electrical current for 1 minute showed higher adhesion strength than that without additional electrical current. However, samples with 10 mA of additional electrical current for more than 10 miniutes showed the degradation of adhesion strength. Ra and RMS values of the peeled polyimide surface were proportional to the adhesion strength though there were no significant changes in the morphology of the peeled surfaces with varied amount and time-length of additional electrical current. Applying electrical current could increase the density of chemical bonding, which results in increase of the adhesion strength between copper and polyimide. However, in the case of applying additional electrical current for excessive amount or time, the degradation of the adhesion strength owing to the formation of copper oxide at the interface could occur.

Effect of Cryopreservation on the Heat Shock Protein 90 Expression in Mouse Ovarian Tissue (동결보존이 생쥐 난소 조직 내 Heat Shock Protein 90의 발현에 미치는 영향)

  • Lee, Sun-Hee;Park, Yong-Seog;Yeum, Hye-Won;Song, Gyun-Jee;Han, Sang-Chul;Bae, In-Ha
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2002
  • Objective : Heat shock protein family is related to protective mechanism of cells by environmental changes. This study was performed to evaluate the effect of cryopreservation on the heat shock protein 90 (Hsp90) expression in mouse ovarian tissue. Methods : Cryopreservation of mouse ovarian tissue was carried out by slow freezing method. The mRNA level of Hsp90 expression in both fresh and cryopreserved mouse ovarian tissue was analyzed by RT-PCR. The protein expression of Hsp90 was evaluated by Western blot analysis and immunohistochemistry. Results: The mRNA and protein of Hsp90 were expressed in both fresh and cryopreserved mouse ovarian tissue. The amount of Hsp90 mRNA was increased in cryopreserved ovarian tissue after 60 and 90 minutes after thawing and incubation. The amount of Hsp90 protein was increased in the cryopreserved ovarian tissue after 6 hours of the incubation in Western blot analysis. In immunohistochemical study, Hsp90 protein was localized in cytoplasm of oocytes and granulosa cells. Significant level of immunoreactive Hsp90 protein was detected in theca cells contrast to the weak expression in ovarian epithelial cells. Conclusion: This results showed the increase of Hsp90 expression in both mRNA and protein level in the cryopreserved mouse ovarian tissue. It can be suggested that Hsp90 may play a role in the protective or recovery mechanism against the cell damage during cryopreservaion.

An Experimental Study on Effects of Soot Loading and Mass Flow Rate on Pressure Drop and Heat Transfer in Catalyzed Diesel Particulate Filter (촉매 코팅 DPF의 soot loading과 유량 변화에 따른 압력강하 및 열전달에 관한 실험적 연구)

  • Cho, Yong-Seok;Noh, Young-Chang;Park, Young-Joon;Kim, Duk-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.72-78
    • /
    • 2007
  • A diesel particulate filter causes progressive increase in back pressure of an exhaust system due to the loading of soot particles. To maintain the pressure drop caused by DPF under proper level, a regeneration process is mandatory when excessive loading of soot is detected in the filter. It is a major reason why the relation between the amount of soot and the pressure drop in a DPF becomes crucial. On the other hand, pressure drop varies with not only the soot loading but also conditions of exhaust gas such as mass flow rate. Therefore, the relation among them becomes complicated. Furthermore, the characteristics of heat transfer in a DPF is another crucial parameter in order for the filter to avoid thermal crack during regeneration period. This study presents characteristics of pressure drop under various conditions of soot loading and mass flow rate in catalyzed diesel particulate filter. This study also shows characteristics of heat transfer in DPF when high temperature gas flows into the filter. Experiments reveal that the soot loading and mass flow rate affect characteristics pressure drop independently. Experiments also indicate that the amount of coating material has little influence on pressure drop with changes in soot loading and mass flow rate. However, increased catalyst coating may lead to the improved heat transfer which is efficiency to reduce thermal stress of the filter.

Comparison of Heat Collection Performance of Water Heating System Using Fixed and Azimuth-Tracking Solar Collectors (고정식과 방위추적식 태양열 급탕시스템의 집열성능 비교)

  • Lee, Jong Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.191-196
    • /
    • 2014
  • The solar water heating system is one of the seven green campus items installed at the Gangneung campus of Gangneung-Wonju National University. The solar water heating system has two types of solar collectors, four storage tanks and monitoring equipment. Fixed and azimuth-tracking solar collectors were installed to collect heat from the sun. The amount of heat collected by the two different types of solar collectors was calculated from the temperature of the monitored storage tanks. Our results showed that the amount of solar heat collected by the azimuth-tracking solar collector was 19% greater on a sunny day and 23% greater on a rainy day than that collected by the fixed solar collector; therefore, the azimuth-tracking solar collectors are, on an average, 21% more efficient than the fixed solar collectors.

Heat Liberation in the Reaction of $YBa_2Cu_3O_{7-}\delta$, $Y_2BaCuO_5$, and Binary Compounds in the Ba-Cu-O System with Water ($YBa_2Cu_3O_{7-}\delta$, $Y_2BaCuO_5$ 및 Ba-Cu-O계 화합물의 수분과의 반응에 의한 열방출에 관한 연구)

  • 김배연
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.1
    • /
    • pp.83-89
    • /
    • 1995
  • YBa2Cu3O7-$\delta$, Y2BaCuO5, and binary compounds in the Ba-Cu-O system with the nominal composition of Ba2CuO3, BaCuO2, Ba3Cu4O7, Ba3Cu5O8 were synthesized to investigate the heat evolutions and crystalline phases in the hydration reaction of orthorhombic YBa2Cu3O7-$\delta$ phase. The observed crystalline phases were YBa2Cu3O7-$\delta$, Y2BaCuO5, and BaCuO2, or Ba2Cu3O5+x, and some amount of noncrystalline phase in the Ba-Cu system comounds. In contact with distilled water, YBa2Cu3O7-$\delta$ and Y2BaCuO5 did not have considerable heat liberation, but in the binary compounds of the Ba-Cu-O system, the amount of total heat liberation was increased with respect to the Cu content. It might be that the reaction of high temperature superconductor YBa2Cu3O7-$\delta$ with water and/or moisture originated from the unusual oxidation state of Cu ion and the presence of amorphous Ba-Cu oxide compound. The degradation of high Tc superconductor by moisture and water could be controlled by restricting the heterogeneous distribution of Tc comlposition and the formation of second phase, such as stable Y2BaCuO5, and the resulting unstable Ba-Cu oxide compound.

  • PDF

Research on using the exhausted heat from subway tunnel as unused energy (미활용 에너지원으로서의 지하철 배열이용에 관한 연구)

  • 김종렬;금종수;최광환;윤정인;박준택;김동규;김보철;정용현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.695-701
    • /
    • 1998
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was peformed as follows. The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying. The results are summarized as follows; 1) Forced ventilation should be conducted to keep optimal temperature in subway tunnel in summer as well as in winter. According to the simulation, temperature in tunnel was higher than that on the ground in summer when the forced ventilation was conducted only in winter. 2) Ventilating time should be calculated out to the optimal condition for not only saving power of ventilation fan but reusing exhausted heat. By the simulation, it is certain that the exhausted heat should be eliminated in air-conditioning time. 3) The use of exhausted heat source heat pump could save 8% of electric power per hour in comparison with existing heat pump. It was based on a present heat generation and traffic for ventilating time of general air-conditioning, but could be different by ventilating time. 4) As the traffic increases up to 1.5 or 2 times, electric power consumption of the conventional heat pump increases to 11% or 13.5% per mean hour in comparison with that of the exhausted heat source heat pump, though all-day ventilation.

  • PDF

A STUDY ON DIFFERENT AMOUNT OF DENTURE BASE DISPLACEMENT USING SOFT DENTURE RELINING MATERIAL UNDER MASTICATORY FORCE (국소의치상을 위한 연성 이장재사용시 교합압에 따른 의치상 변위(Displacement)량 비교)

  • Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.18-25
    • /
    • 1998
  • The purpose of this study was to determine how to use soft relining material by observing an amount of denture displacement according to the different base area of residual ridge and thickness of soft relining material under masticatory force. Stone models that simulated residual ridge were made with different amount of denture base area and denture was fabricated by conventional heat curing resin with usual manner on the model and relined by silicone type soft relining material with different thickness. Specimen was examined the amount of denture displacement by Instron within range of normal occlusal force. The results were as following : 1. The increasing rate of denture displacement was higher than that of soft relining material thickness. 2. The amount of denture displacement decreased 1.7 times when base area became double at same thickness of soft relining material 3. The increasing rate of denture displacement was higher than that of occlusal force

  • PDF