• Title/Summary/Keyword: Ammonia removal rate

Search Result 224, Processing Time 0.025 seconds

Examine the Proper Operating Conditions in the Seawater Fluidized Bed filter System (해수 유동층 여과시스템의 적정 운용 조건)

  • Son Maeng-Hyun;Cho Kee-Chae;Jeon Im-Gi;Lim Han Kyu;Park Min-Woo
    • Journal of Aquaculture
    • /
    • v.18 no.4
    • /
    • pp.280-286
    • /
    • 2005
  • Experiments were conducted to examine the differences in ammonia removal rates with the different filter media between sand and zeolite, the expanding rates between $50\%$ and $100\%$, the water temperatures between $15^{\circ}C$ and $25^{\circ}C$, and the ammonia loading rates between 2 mg/L and 5 mg/L in the seawater fluidized bed filters system (FBF). The 2.1 m high FBF (8.3 cm diameter) consisted of the clear acrylic for the upper half and a PVC pipe for the lower half, Sand and zeolite were used as the filter media in sizes of 0.5$\pm$0.1mm. Each biofilter contained 5.4 L of media. The ammonia removal rates of the biofilter were higher at the $25^{\circ}C$ water temperature than those of the biofilter at $15^{\circ}C$ water temperature, and higher at the $50\%$ expanding rate of filter media than those of the biofilter at $100\%$ expanding rate of filter media. Also, the ammonia removal rates of FBF were higher at 5 mg/L ammonia concentration than those of FBF at 2 mg/L ammonia concentration in rearing water. With these better conditions the ammonia removal rates of FBF per day are practically acceptable and ranged ken 80.6 to $210.6g/m^3$.

Effect of Ammonia Nitrogen Loading Rate on the Anaerobic Digestion of Slurry-typed Swine Wastewater (슬러리형 돈사폐수의 혐기성 소화시 암모니아 부하의 영향)

  • Won, Chul-Hee;Kwon, Jay-Hyouk;Rim, Jay-Myoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • This research examined the effect of ammonia nitrogen loading rate(NVLR) on the anaerobic digestion of slurry-typed swine wastewater. The anaerobic reactor was used an upflow anaerobic sludge blanket (UASB) process. This UASB reactor was operated at a NVLR of $0.02{\sim}0.96kg{NH_4}^+-N/m^3/day$. The methane content showed the range of 73.3~77.9% during the steady state period. Free ammonia(FA) concentration increased over inhibition level as pH increase from 7.3 to 8.2. However, in consideration of methane content, methane producing bacteria (MPB) inhibition by FA and total ammonia(TA) was not observed. A stepwise increase of the NVLR resulted in a deterioration in the COD removal rate in UASB reactor. The COD removal rate were 60% for NVLR up to $0.55kg{NH_4}^+-N/m^3/day$. As the NVLR increased from 0.09 to $0.96kg{NH_4}^+-N/m^3/day$, the biogas production rate varied from 3.71 to 9.14L/d and the methane conversion rate of the COD varied from 0.32 to $0.20m^3CH_4/kg$ COD removed. Consequently, in considerations of FA concentration, COD removal rate, and $CH_4$ production rate, the UASB reactor must be operated to lower than $0.40kg{NH_4}^+-N/m^3/day$ of NVLR.

  • PDF

Preparation of Nitrifier Immobilized PVA(Polyvinyl Alcohol) Bead and Removal of Ammonia Nitrogen (질화세균군이 고정화된 PVP(Polyvinyl Alcohol) bead 제조 및 암모니아성 질소 제거)

  • 서근학;조진구
    • Journal of Environmental Science International
    • /
    • v.10 no.3
    • /
    • pp.233-237
    • /
    • 2001
  • Immobilized nitrifier bead in airlift bioreactor were used to remove high levels of ammonia nitrogen from synthetic wastewater. Polyvinylalcohol(PVA) bead for immmobilization of nitrifier consortium were prepared by PVA-boric acid method by varying concentration of PVA and nitrifier consortium. By determining viscosity, sphercity and tailing, the characteristics of prepared beads were investigated and the continous immobilization process was developed. Synthetic wastewater containg 25g/$\textrm{m}^3$ of ammonia nitrogen could be treated within 0.5 hour and the highest removal rate of ammonia nitrogen was 934.2g/$\textrm{m}^3{\cdot}$ day.

  • PDF

Effect of high free ammonia concentration on microalgal growth and substrate uptake (폐수 내 고농도 free ammonia(FA)가 미세조류의 성장 및 기질제거에 미치는 영향 평가)

  • Kim, Eun-Ji;Cho, Jae Hyung;Noh, Kyung Ho;Nam, guisook;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.715-723
    • /
    • 2016
  • This study investigated the effect of high concentration of free ammonia on microalgal growth and substrate removal by applying real wastewater nitrogen ratio. To test of this, the conditions of free ammonia 1, 3, 6, 9, 12, 15 mg-N/L are compared. After 3 days of incubation, algal growth of Chlorella vulgaris and carbon removal rate are respectively lower in the reactors of FA 12, 15 mg-N/L compared to the others. This indicates that the high concentration of free ammonia, in this case, above 12 mg-N/L, has negative effect on algal growth and metabolic activity. Also, high concentration of free ammonia causes the proton imbalance, ammonium accumulation in algae and has toxicity for these reasons. So, we have to consider free ammonia in applying the microalgae to wastewater treatment system by the way of diluting wastewater or controlling pH and temperature.

Simultaneous Treatment of Carbon Dioxide and Ammonia by Microalgal Culture (조류배양을 통한 이산화탄소 및 암모니아의 동시처리)

  • ;;Bohumil Volesky
    • KSBB Journal
    • /
    • v.14 no.3
    • /
    • pp.328-336
    • /
    • 1999
  • A green microalga, Chlorella vulgaris UTX 259, was cultivated in a bench-scale raceway pond. During the culture, 15%(v/v) $CO_2$ was supplied and industrial wastewater discharged from a steel-making plant was used as a culture medium. In a small scale culture bottle, the microalga grew up to 1.8 g $dm^{-3}$ of cell concentration and ammonia was completely removed from the wastewater with an yield coefficient of 25.7 g dry cell weight $g^{-1}\;NH_3-N$. During the bottle-culture, microalga was dominant over heterotrophic microorganisms in the culture medium. Therefore, the amount of carbon dioxide fixation could be estimated from the change of dry cell weight. In a semi-continuous operation of raceway pond with intermittent lighting (12 h light and 12 h dark), increase of dilution rate resulted in increase of the ammonia removal rate as well as the $CO_2$ fixation rate but the ammonia removal efficiency decreased. Ammonia was not completely removed from the medium (wastewater) of raceway pond which was operated in a batch mode under a light intensity up to 20 klux. The incomplete removal of ammonia was believed due to insufficient light supply. A mathematical model, capable of predicting experimental data, was developed in order to simulate the performance of the raceway pond under the light intensity of sun during a bright daytime. Simulation results showed that the rates of $CO_2$ fixation and ammonia removal could be enhanced by increasing light intensity. According to the simulation, 80 mg $dm^{-3}$ of ammonia in the medium could be completely removed if the light intensity was over 60 klux with a continuous lighting. Under the optimal operating condition determined by the simulation, the rates of carbon dioxide fixation and ammonia removal in the outdoor operation of raceway pond were estimated as high as $24.7 g m^{-2} day^{-1}$ and $0.52 g NH_3-N m^{-2} day^{-1}$, respectively.

  • PDF

Performance and Operation of Biological Activated Carbon (생물활성탄접촉조의 성능과 조작)

  • Lee, Gangchoon;Yoon, Taekyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.83-90
    • /
    • 2006
  • Performance and operation of BAC in ozone-BAC advanced water treatment process were investigated using the pilot scale test plant built in D water purification plant. The performance was evaluated by the removal efficiencies of DOC, BDOC, ammonia nitrogen and THMs. The effect of EBCT on DOC removal was experimented for an effective operating condition, and the amount of attached biofilm was analyzed in various water temperatures and position of BAC. Two removal mechanisms, adsorption and biological decomposition by attached biofilm, were predominant to decrease the concentration of various contaminants. DOC was removed 40%, and the removal rate was decreased in winter time due to the lowered activity of attached biofilm. BDOC was effectively removed. THMs and ammonia nitrogen were mainly removed not in ozonation process but in BAC. Water temperature deeply influenced in removal efficiency of ammonia nitrogen. The amount of attached biofilm depended on water temperature and height of packed activated carbon column. Considering DOC removal efficiency and design EBCT of commercial BAC plant, the proper EBCT was 12.5 minutes.

Evaluation of the Applicability of Livestock Wastewater Treatment using Boron-Doped Diamond (BDD) Electrodes (BDD 전극을 이용한 축산폐수 처리의 적용성 평가)

  • Hyun-Gu Kim;Dae-Hee Ahn
    • Journal of Environmental Science International
    • /
    • v.32 no.6
    • /
    • pp.465-475
    • /
    • 2023
  • In this study, we evaluated the treatment efficiency of livestock wastewater by altering the current density using boron-doped diamond (BDD) electrodes. As the current density was adjusted from 10 to 35 mA/cm2, the removal efficiency of organic matter increased from 22.2 to 71.5%. Similar to that of organic matter, the removal efficiency of color increased with increasing current density up to 85.7%, indicating a higher removal efficiency for color than that of organic matter. The removal efficiency of ammonia nitrogen increased from 14.6 to 53.3% as the current density increased, but it was lower than that of organic matter. In addition, the removal of organic matter, color, and ammonia nitrogen followed first-order reactions, according to the reaction rate analysis. The energy consumption ranged from 4.87 to 8.33 kWh/kg COD, and it was found that the organic matter removal efficiency was more efficient at high current densities. Based on various analyses, the optimal current density was 20 mA/cm2, and the corresponding energy consumption was 6.824 kWh/kg COD.

Removal of Suspended Solids and Nitrification by Floating Bead Filter in Recirculating Aquaculture System (Floating Bead Filter에 의한 순환여과식 양식장의 부유고형물 제거와 질산화)

  • KIM Byong Jin;KIM Sung Koo;SUH Kuen Hack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.2
    • /
    • pp.163-169
    • /
    • 2003
  • The floating bead filter was tested for treatment of aquacultural water in a pilot-scale recirculating aquaculture system. Performance of floating bead filter on the removal of total suspended solids (TSS) and the treatment of nitrogen sourer such as total ammonia nitrogen (TAN), nitrite nitrogen and nitrate nitrogen were evaluated. The system was stocked with Nile tilapia at an initial rearing densities of $5\%\;and\;7\%$ over 30 days. The average TSS removal rates were $43.0\;g/m^2{\cdot}day\;and\;39.5\;g/m^2{\cdot}day$ for rearing density of $5\%\;and\;7\%$, respectively. As rearing density increased from $5\%\;to\;7\%$. the TAN removal efficiency decreased from $22.0\%\;to\;17.7\%$. At the rearing densities of $5\%\;and\;7\%$, the average TAN removal rates and removal efficiencies were $38.8\;g/m^2{\cdot}day,\;15.6\%\;and\;37.8\;g/m^2{\cdot}day.\;17.7\%,$ respectively. The average TAN removal rate was $37.8-38.8\;g/m^3{\cdot}day.$ The oxygen consumption by floating bead filter was higher than theoretical oxygen consumption rate by nitrification.

The Studies of Photocatalyst Development and the Optimum Operation Conditions for the Removal of Ammonia in a Mixed Reactor of Liquid-vapor Phase (기-액 복합 광반응기에서의 악취성 암모니아 제거를 위한 촉매개발과 반응시스템의 최적조건 색출 연구)

  • Kim, Hae-Ri;Jeon, Min-Kyu;Kim, Joon-Woo;Joo, Gwang-Tae;Choung, Suk-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.512-522
    • /
    • 2008
  • Ammonia is a major compound of odor in livestock house. To enhance the performance of ammonia oxidation (decomposition). the gas-liquid, two phase photocatalytic oxidation system was designed and prepared in this study. Commercial P-25 as $TiO_2$ catalyst was used for ammonia decomposition. V/P-25 catalyst prepared by sol gel method was also used for the removal of by-producted $NO_x$ in $NH_3$ oxidation reaction. When $TiO_2$ was used as a photocatalyst, the conversion to $N_2$ in ammonia decomposition reached above 90% until 200hr (The air flow rate of 4L/min with the ammonia concentration up to 25ppm.). However, considerable amounts of NO and $NO_2$ were formed as a result of $NH_3$ oxidation (as a by-product). Therefore, we added Vanadia impregnated $TiO_2$(P-25) catalyst for the removal of $NO_x$ at the end of reaction trail. The results of a pilot-scale operation were successful to achieve the simultaneous removal of $NH_3\;and\;NO_x$ about 81 and 87%, respectively.

Performance Evaluation of Biofilter Treating Autothermal Thermophilic Aerobic Digestion Offgas (고온호기성 소화공정 배가스 처리를 위한 바이오필터 성능평가)

  • Bae, Byung-Uk;Choi, Ki-Seung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.732-739
    • /
    • 2010
  • Two combined autothermal thermophilic aerobic digestion (ATAD) and biofilter (BF) systems were operated to treat the piggery wastewater and the ammonia offgas. Experimental results indicated that the organic removal efficiency of ATAD-2, operated with oxygen, was higher than that of ATAD-1, operated with air. The concentration of ammonia in ATAD-2 offgas was higher compared to ATAD-1 offgas, but the total amount of ammonia produced from ATAD-2 was less than that from ATAD-1 due to the lower oxygen flowrate. The ammonia gas produced from both ATAD reactors was successfully removed by the BF. The BF-1, connected with ATAD-1, removed 93% of ammonia at the loading rate of $9.4g\;NH_3-N/m^3/hr$. The BF-2, connected with ATAD-2, removed 95% of ammonia gas at the loading rate of $8.1g\;NH_3-N/m^3/hr$. As the nitrification process continued, pH value of recirculating solution continuously decreased due to the accumulation of nitrate. When the ammonia loading rate was less than $22.7g\;NH_3-N/m^3/h$, the proper replacing cycle of recirculating solution was in the range of 10 to 11 days. Almost 90% of total mass of nitrogen fed into the each BF was confirmed from the mass balance on nitrogen.