• Title/Summary/Keyword: Ambient Control

Search Result 606, Processing Time 0.031 seconds

Enhancement of the Speed Response of PMSM Sensorless Control Using A New Adaptive Sliding Mode Observer (새로운 적응 슬라이딩 모드 관측기를 이용한 PMSM 센서리스 속도 응답특성 향상)

  • Kim, Hong-Ryel;Son, Ju-Beom;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.160-167
    • /
    • 2010
  • This paper proposes an adaptive sliding mode observer (SMO), which adds the estimation function of the stator resistance to a new sliding mode observer for the robust sensorless control of permanent magnet synchronous motor (PMSM) with variable parameters. To reduce the chattering problem commonly found in the conventional sliding mode observer where the low-pass filter and additional position compensation of the rotor are used, the sigmoid function is used for the control of a switching function in this research. With the estimation of the stator resistance, the proposed observer can improve the control performance by reducing the estimation error of the motor's speed. Note that the stator resistance is varying with the ambient temperature and becomes an error source for the sensorless control of PMSM. The new sliding mode observer has better efficiency than the conventional adaptive sliding mode observer by reducing the time consuming integral calculations. The stability of the proposed adaptive sliding mode observer is verified by the Lyapunov function in determining the observer gains, and the effectiveness of the observer is demonstrated by simulations and experiments.

Measurement of VOC in the Ambient Air of a Small Scale Municipal Landfill Site -A Case Study at the Sampung-dong Landfill in Gyungsan City- (소규모 도시 생활폐기물 매립장 대기 중 VOC의 농도 측정 -경산시 삼풍동 매립장을 대상으로-)

  • 백성옥;김배갑;서영교
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.1
    • /
    • pp.59-68
    • /
    • 2004
  • In this study, we investigated the concentrations of volatile organic compounds (VOC) in the ambient air of a small scale municipal waste landfill site. Seasonal sampling was carried out simultaneously at two sites, i.e. one in the center of the landfill area, and the other at a boundary site. Among 38 target VOC, toluene appeared to be the most dominant compound, followed by benzene. and xylenes. The higher levels of BTX imply that paint -containing materials and/or organic solvents are the most significant sources of the VOC in the landfill environment. Seasonal variations for the samples collected at the landfill site indicated that the VOC concentrations tend to be higher in the spring and fall season and lower in the winter season. In addition, night- time concentrations appeared to be generally higher than day-time. Such daily variation might be due to more stabilized atmosphere during the night-time. Similar patterns were also found in samples collected at a boundary site. This study demonstrated that the municipal landfill, although it is small -scaled, could be an important emission source of atmospheric VOC, particularly in the vicinities of the landfill. Thus, an appropriate control strategy is required to prevent any undesirable secondary pollutions from the environmental sanitary facilities such as landfill.

Robust finite element model updating of a large-scale benchmark building structure

  • Matta, E.;De Stefano, A.
    • Structural Engineering and Mechanics
    • /
    • v.43 no.3
    • /
    • pp.371-394
    • /
    • 2012
  • Accurate finite element (FE) models are needed in many applications of Civil Engineering such as health monitoring, damage detection, structural control, structural evaluation and assessment. Model accuracy depends on both the model structure (the form of the equations) and the model parameters (the coefficients of the equations), and can be generally improved through that process of experimental reconciliation known as model updating. However, modelling errors, including (i) errors in the model structure and (ii) errors in parameters excluded from adjustment, may bias the solution, leading to an updated model which replicates measurements but lacks physical meaning. In this paper, an application of ambient-vibration-based model updating to a large-scale benchmark prototype of a building structure is reported in which both types of error are met. The error in the model structure, originating from unmodelled secondary structural elements unexpectedly working as resonant appendages, is faced through a reduction of the experimental modal model. The error in the model parameters, due to the inevitable constraints imposed on parameters to avoid ill-conditioning and under-determinacy, is faced through a multi-model parameterization approach consisting in the generation and solution of a multitude of models, each characterized by a different set of updating parameters. Results show that modelling errors may significantly impair updating even in the case of seemingly simple systems and that multi-model reasoning, supported by physical insight, may effectively improve the accuracy and robustness of calibration.

Estimation of Source Contribution for Ambient Particulate Matters in Suwon Area (수원지역 입자상 오염물질의 오염원 기여도의 추정)

  • 이태정;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.285-296
    • /
    • 1997
  • The suspended particulate matters had been collected on quartz fiber fiters by a cascade impactor having 9 size stages for 4 years (Sep. 1991 to Dec. 1995) in Kyung Hee University-Suwon Campus. Membrane filters were used to collected the particulate matters on each stage. The weight concentration on each stage was obtained by a microbalance and further chemical element levels were determined by an x-ray fluorescence system. Based on these chemical information, our study focused on applying the target transformation factor analysis (TTFA), a receptor model, to identify aerosol sources and to apportion quantitatively their mass contribution. There are total of 63 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 16 elemental variables. By the results, four to five sources were extracted from each size range and some sources reappeared in other size ranges. Then total of 8 source profiles were statistically generated from all the ranges, such as oil burning source, soil source, field burning source, gasoline related source, coal burning source, marine source, glass related source, and unknown sources. Apportioning aerosol mass to each source was intensively examined by investigating emission inventories near the study area. The results showed that soil particle source was the most significant contributor. However, coal and oil burning sources were the major anthropogenic ones. The study finally proposed some air quality control strategies to achieve the clean air quality in Suwon area.

  • PDF

The Study for Characteristic of Direct Methanol Fuel Cell in Ambient Temperature (상온 상태에서 직접 메탄올 연료전지의 특성 연구)

  • Yun, Hyo-Jin;Kim, Jeong-Ju;Kim, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.955-961
    • /
    • 2009
  • Present, a portable battery have problem that the volume increases according to capacity Increase. Direct Methanol Fuel Cell is alternative by solution plan of this problem. In this paper, the characteristics of DMFC are analyzed by change in concentration and discharge of fuel in natural convection and room temperature condition. According to the analysis result, polarization by delay of diffusion velocity of hydrogen ion appeared in methanol of low concentration. And if have a lot of supplies of methanol, generation power declines by electric cell cooling effect.

Characteristics of Hazardous Air Pollutants in the Steel Industrial City, Pohang (II) - Volatile Organic Compounds (철강산업도시 포항지역 유해대기오염물질의 오염특성 (II) - 휘발성유기화합물)

  • Kim, Min-ji;Seo, Young-Kyo;Cho, Byoung-Yoon;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.244-258
    • /
    • 2018
  • We performed this study to investigate the spatial, seasonal, and daily variations of the concentrations of volatile organic compounds (VOCs) in Pohang, where large steel industrial complexes are located. Ambient air sampling was undertaken at 4 sites during 4 seasons. Each sample was taken for 4 hours continuously for 8 consecutive days per season at each site. Three sites were located within the Pohang city, but one as a control site in Gyeongju. A total of 72 individual VOCs were determined by thermal desorption coupled with GC/MS, including aliphatics, aromatics, carbonyls and halides. The most abundant VOC was toluene, being followed by ethylbenzene and xylenes. Benzene concentrations(c.a. 0.7 ppb) were found to be much lower than the national ambient standard of 1.5 ppb. Overall, the VOCs levels in Pohang appeared to be lower than other national industrial complexes in Korea such as Shiwha-Banwol, Yeosu-Gwangyang, Gumi, and Ulsan. This implies that steel industry may not give significant impacts on the atmospheric levels of VOCs as much as petrochemical, electronic, and/or textile industries, where large amounts of organic solvents are used.

Study of plasma induced charging damage and febrication of$0.18\mu\textrm{m}$dual polysilicon gate using dry etch (건식각을 이용한 $0.18\mu\textrm{m}$ dual polysilicon gate 형성 및 plasma damage 특성 평가)

  • 채수두;유경진;김동석;한석빈;하재희;박진원
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.4A
    • /
    • pp.490-495
    • /
    • 1999
  • In 0.18 $\mu \textrm m$ LOGIC device, the etch rate of NMOS polysilicons is different from that of PMOS polysilicons due to the state of polysilicon to manufacture gate line. To control the etch profile, we tested the ratio of $Cl_2$/HBr gas and the total chamber pressure, and also we reduced Back He pressure to get the vertical profile. In the case of manufacturing the gate photoresist line, we used Bottom Anti-Reflective Coating (BARC) to protect refrection of light. As a result we found that $CF_4O_2$ gas is good to etch BARC, because of high selectivity and good photoresist line profile after etching BARC. in the results of the characterization of plasma damage to the antenna effect of gate oxide, NO type thin film(growing gate oxide in 0, ambient followed by an NO anneal) is better than wet type thin film(growing gate oxide in $0_2+H_2$ ambient).

  • PDF

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

A simulation on the energy saving based on different temperature tracing method and weather condition in electrical power plant (화력발전소 배관시스템의 운전 및 기후조건에 따른 에너지절감에 관한 시뮬레이션)

  • Han, Kyu-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.1
    • /
    • pp.67-74
    • /
    • 2014
  • Most of steam power plants in Korea are using the method of heating the feed water whenever the ambient temperature around the power plant area below $5^{\circ}C$ to prevent freezing water flowing in the pipe in winter time. But this kind of heat supplying system is not useful to save energy. If we take the method that the temperature of the each pipe is controled by direct measure of temperature by attaching sensor on the outside surface of the feed water tubes, then we can expect that a plenty of energy can be saved. In this study, the computer simulation is used to compare the energy consumption loads of both systems. Energy saving rate is calculated for the location of Incheon area in winter season. Four convection heat transfer coefficients for the ambient air and three initial flowing water temperature inside the tube were used. The result shows that the temperature control system using sensor represents more than 95% of energy saving rate in Incheon area. Even in the severe January weather condition, the energy saving rate is almost 75% in two days basis and even 83% in one day basis.

Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System (일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석)

  • Lee, Joon-Koo;Sohn, Kwang-Young;Park, Hee-Seok;Park, Heui-Yun;Koo, In-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF