• 제목/요약/키워드: Ambient Control

검색결과 606건 처리시간 0.026초

Recognition of Material Temperature Response Using Curve Fitting and Fuzzy Neural Network

  • Ryoo, Young-Jae;Kim, Seong-Hwan;Chang, Young-Hak;Lim, Yong-Cheol;Kim, Eui-Sun;Park, Jin-Kyn
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권2호
    • /
    • pp.133-138
    • /
    • 2001
  • This paper describes a system that can used to recognize an unknown material regardless of the change of ambient tem-perature using temperature response curve fitting and fuzzy neural network(FNN). There are some problems to realize the recogni-tion system using temperature response. It requires too many memories to store the vast temperature response data and it has to be filtered to remove noise which occurs in experiment. And the temperature response is influenced by the change of ambient tempera-ture. So, this paper proposes a practical method using curve fitting the remove above problems of memories and nose. And FNN is propose to overcome the problem caused by the change of ambient temperature. Using the FNN which is learned by temperature responses on fixed ambient temperature and known thermal conductivity, the thermal conductivity of the material can be inferred on various ambient temperature. So the material can be recognized by the thermal conductivity.

  • PDF

아질산에 노출된 뱀장어(Anguilla japonica)의 혈액학적 반응과 항산화효소의 활성 변화 (Changes in Hematological Responses and Antioxidative Enzyme Activities of Japanese Eel Anguilla japonica Exposed to Elevated Ambient Nitrite)

  • 조수현;김흥윤
    • 한국수산과학회지
    • /
    • 제47권6호
    • /
    • pp.860-868
    • /
    • 2014
  • The study was performed to investigate changes in hematological responses and antioxidative enzyme activities (superoxide dismutase, SOD; catalase, CAT) of Japanese eel Anguilla japonica following exposure to 0 (control), 2.33, 4.60, 6,64 and 8.78 mM nitrite-N in fresh water for 48 h. Hematological parameters such as plasma nitrite, electrolytes, cortisol, glucose, glutamate oxaloacetate transaminase (GOT), glutamate pyruvate transaminase (GPT), hemoglobin (Hb), methemoglobin (metHb) and NADH-methemoglobin reductase (NMR) were measured. Plasma nitrite, cortisol, metHb and NMR increased directly with increasing ambient nitrite concentration, while Hb content showed a progressive decline. Levels of plasma potassium, GOT and GPT of the eel exposed to 6.64 mM ambient nitrite were significantly higher than the control fish. The activity of SOD and CAT in plasma, gill and liver of the eel following exposure to nitrite were augmented by increasing ambient nitrite. Levels of plasma nitrite, metHb, NMR, cortisol, glucose and antioxidative enzyme activities of the eel exposed to 2.33 mM ambient nitrite were significantly higher than the control fish. This study suggested that the eel acutely exposed to elevated ambient nitrite causes nitrite-induced stress responses, changes in antioxidative enzyme activities and hematological parameters.

용해로 운전에서 Setting고정(4M 표준화)의 효율적 방안 (Efficient Method of fixing the Setting(4M standardization) in Melting furnace Operation)

  • 장도수;이세재;서정열;김이남;정종원;조진형
    • 산업경영시스템학회지
    • /
    • 제30권1호
    • /
    • pp.96-104
    • /
    • 2007
  • Glass melting process is influenced by both control and observation factors, where control factors include quantity and mixing ratio of raw material, the amount of fuel and air in-take. Further observation factors include temperature and pressure at each step of process inside glass melting furnace. Ambient Control is an effective means to eliminate complications from excessive variation among raw materials, or external disturbance from wide fluctuation of environment around equipments. Ambient Control uses both control and observation factors mentioned above. This study suggests an effective Proactive Control System that can enable genuine 4M standardization in glass melting furnace by applying Ambient Control.

고압환경에서 이미지 프로세싱 기법을 이용한 액적크기 측정 (Drop Size Measurement using Image Processing Method under High Ambient Pressure Condition)

  • 임병직;길태옥;정기훈;윤영빈
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.111-114
    • /
    • 2003
  • Drop size is one of the most important parameters which are control the performance of the engine using liquid fuel/oxidizer and drop formation is mainly controlled by aerodynamic force caused by ambient gas. Because of this, empirical data and correlation acquired under standard ambient condition are not valid. So experiments under high ambient pressure condition to measure the drop size using image processing method And find the empirical correlation between SMD and chamber pressure(density), injection velocity.

  • PDF

야간 고온에 의한 사과 후지 품종의 생리반응 및 과실품질 변화 (Physiological Responses and Fruit Quality Changes of 'Fuji' Apple under the High Night Temperature)

  • 류수현;권용희;도경란;한점화;한현희;이한찬
    • 생물환경조절학회지
    • /
    • 제24권3호
    • /
    • pp.264-270
    • /
    • 2015
  • 최근 지구 온난화로 인해 열대야 발생 빈도가 증가하고 있으며, 야간 저온의 감소에 의한 사과의 착색 불량이 예상된다. 따라서 본 연구는 생육기 후반의 야간 고온이 '후지' 사과에 미치는 영향을 구명하기 위해 성숙기 과실 품질과 시기별 안토시아닌 생합성 유전자의 발현량을 조사하였고, 잎과 과실 내 당 함량을 비교하여 야간 고온에 의한 생리반응을 구명하고자 실시하였다. 야간온도는 7월부터 10월까지 인공기상실 내부에서 처리하였고, 대기온도 대비 $-4^{\circ}C$, $+4^{\circ}C$ 로 각각 설정하였다. 야간 고온은 과실의 횡경, 과중, 당도에 영향을 미치지 않았고 과피의 착색을 불량하게 하였지만, 착색 시기의 안토시아닌 생합성 유전자의 발현량을 변화시키지 않았다. 또한, 야간 고온에 의해서 잎의 sorbitol, glucose 함량과 과실의 sorbitol, sucrose 함량이 대조구에 비해 감소하였고, 잎 조직을 구성하고 있는 책상, 해면 등의 광합성 조직에는 차이가 나타나지 않았지만 광합성 조직 내의 전분 함량이 감소하였다. 따라서 야간 고온은 '후지' 사과의 과실 품질에는 영향을 미치지 않았지만, 잎과 과실의 당 조성을 변화시켰으며, 안토시아닌 생합성 유전자의 발현과는 관계없이 과피의 착색을 억제하였다.

Effects of L-arginine on Endothelium Derived Factors and Cyclic Nucleotides in Broilers under Low Ambient Temperature

  • Han, Bo;Yoon, Soonseek;Han, Hongryul;Wang, Xiaolong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1570-1574
    • /
    • 2004
  • A flock of AA breed chickens were reared in peterstme brood-vait chamber and were provided with high energy pelleted feed. At 14 d of age, a total of 350 birds were randomly divided into 3 groups as follows: 100 birds were exposed to normal ambient temperature of 20$^{\circ}C$ for control group; 150 birds were exposed to lower ambient temperature of 11$^{\circ}C$ to induce ascites (treatment I); and another group of 100 birds were exposed to lower ambient temperature of 11$^{\circ}C$ and fed diet containing 1% L-arginine for ascitic prophylactic treatment (treatment II). Samples were collected from blood and abdominal fluid of chicken at 3, 4, 5, 6 and 7 wk of age subsequently, to analysis the contents of plasma endothelin (ET-1), angiotensin II (Ang II), cyclic adenosine monophosphate (cAMP), cyclic guanosine monophosphate (cGMP). The results indicated that the contents of cAMP, cGMP, and Ang II in reatment I and ascitic broilers were higher than the corresponding control group (p<0.01, p<0.05), ET-1 of preascitic broilers were control group (p<0.05), while there was an insignificant difference with later ascitic broilers. The contents of cAMP and cGMP in treatment II were higher than the treatment I and control groups (p<0.01, p<0.05), whereas, the contents of Ang II were gradually decreased compared to the control group (p<0.05), the contents of ET-1 were insignificantly different. On further analysis, the increased plasma Ang II at low ambient temperature condition in broilers made endothelium cell secretion of increased ET-1, cAMP, cGMP and decreased NO. Therefore, low temperature accelerated ascites syndrome in broilers. Supplemently L-arginine can decrease ET-1, and increase cAMP and cGMP. It is concluded that cAMP mediated in broilers pulmonary hypertension syndrome.

교량건전성 평가의 개선을 위한 상시진동시험 (Ambient Vibration Tests for Enhanced Bridges Integrity Assessment)

  • 이진학;이종재;이창근;이원태;윤정방
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.611-614
    • /
    • 2004
  • In this study, ambient vibration tests are carried out to replace the current bridge integrity assessment using controlled vehicle test, which requires the traffic control and may induce public complains. Ambient vibration tests and output-only modal identification can be very effective approach to evaluate the bridge integrity because the ambient vibration tests can be performed very easily without trafnc control. The bridges in test road of Jungbu Inland Highway were tested and the results are discussed here.

  • PDF

분위기 조건이 Decane 액적의 Soot 생성에 미치는 영향 (Effect of Ambient Conditions on the Soot Generation of Decane Fuel Droplet)

  • 임영찬;서현규
    • 한국분무공학회지
    • /
    • 제19권4호
    • /
    • pp.211-215
    • /
    • 2014
  • The main purpose of this study is to provide basic information of droplet soot generation of decane fuel. To achieve this, this paper presents the experimental results on the decane droplet combustion conducted under various ambient pressure($P_{amb}$), and oxygen concentration($O_2$) conditions. At the same time, the experimental study was conducted in terms of soot volume fraction($f_v$) and its maximum value. Also, visualization of single fuel droplet was conducted by high resolution CCD camera and ambient pressure($P_{amb}$) and oxygen concentration($O_2$) was changed by control system. It was revealed that higher ambient pressure($P_{amb}$), and oxygen concentration($O_2$) enhanced the soot generation and improved the maximum soot volume fraction( $f_v$).

충격성 소음 감소용 COS 홀더 개발 (A Development of COS Holder to Reduce an Impact Ambient Noise)

  • 조현섭
    • 한국산학기술학회논문지
    • /
    • 제8권5호
    • /
    • pp.1062-1068
    • /
    • 2007
  • 변압기 보호와 과전류를 막기 위한 목적으로 COS를 사용하고 있다. 그러나 COS 휴즈는 과전류가 흐르면 과부하에 의하여 용단되면서 강한 아크를 발생하여 공기 절연파괴를 일으킨다. 이러한 현상은 소음을 발생하면서 주변 거주자나 행인들에게 두려움을 준다. 그래서 실제 환경하에서 발생되는 소음을 시급히 정립할 필요가 있다. 본 논문은 COS 휴즈가 용단되면서 발생하는 충격성 소음의 특성을 파악하고 이러한 소음을 줄일 수 있는 방안을 제안한다.

  • PDF

인버터 압축기를 채용한 산업용 수냉각기의 외기온도 변화에 따른 용량제어 특성 (The Characteristic Study of Capacity Control of an Industrial Cooler Using an Invertor Compressor with Varing the Ambient Temperatures)

  • 백승문;문춘근;김은필;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.238-243
    • /
    • 2011
  • 인버터형 가변속 압축기를 사용한 냉각기를 최적으로 제어하기 위한 선행 연구이며, 외기온도를 변화 시켰을 경우 압축기의 회전수 변화와 전자팽창밸브의 개도 변화가 전체 시스템에 미치는 영향에 대해 실험적으로 규명하였다. 외기온도 $35^{\circ}C$와 외기온도 $30^{\circ}C$의 30Hz에서는 제어 시 피해야할 영역으로 판단됨을 확인할 수 있었으며, 압축기 회전수 제어로 인한 용량 제어범위는 외기온도 $35^{\circ}C$에서의 약 43~100%, 외기온도 $25^{\circ}C$에서는 46~100%, 외기온도 $10^{\circ}C$에서는 48~100%로 외기온도가 낮아질수록 용량제어범위는 작아짐을 알 수 있었다.