• Title/Summary/Keyword: Alpha imaging

Search Result 216, Processing Time 0.023 seconds

A Study on Nurse' Image in a Medical Center (일 대학병원 간호사 이미지에 관한 연구)

  • Han, Sang-Sook;Sohn, In-Soon;Lee, Myung-Hai;Choi, Kyoung-Soon
    • Journal of East-West Nursing Research
    • /
    • v.8 no.1
    • /
    • pp.113-125
    • /
    • 2003
  • This study is a descriptive investigation into the image of nurses, and attempted to help to advance the profession of nursing and to provide basic data for developing strategies to improve the image of nurses. The Subject of this study was a group of 380 persons from a K Medical Centre in Seoul, including the hospital patients and their guardians, as well as the doctors, assistants and hospital administrative staff. The data have been collected from the 10th to the 30th of May, 2003. We have developed a research tool of 40 questions divided into three categories using a tool developed by Kim, H.J and KIm, H.O.(2001) verifying its construct validity. The reliability of the tool was Cronbache's ${\alpha}=.97$, and by categories, Cronbach's ${\alpha}=.86$ for service image, Cronbach's ${\alpha}=.96$ for professional image and Cronbache's ${\alpha}=.90$ for social image. The collected data have been analysed according to the purpose of this study using SPSS WIN 11.0 for real number, percentage, factors analysis, multiple regression analysis, ANOVA and $x^2$-test, and the results are as follows: 1) There was a significant difference in the image of nurses by job series of the subjects; from patients and guardians for 4.01 to doctors 3.62, assistants 3.54 and staff members 3.41 (F=36.14, p=.000). As well, there was a significant difference in service, professional and social image categories according to the position of the subjects ($F=20.36{\sim}42.35$, p=.000). 2) The main factors that affect on formation the nurse's imaging came by direct experiences with nurses at hospitals for 81.3%, by looking at the every life of the nurses that the subjects personally know for 15.5%, by mass media for 1.6% and by the accounts from the others for 1.6%. 3) 78.4% of the subjects considered that the image of nurses on mass media is described better than for real, 8.2% believed that the image is described worse than for real, and only 13.2% of the subjects perceived that the image of nurses on mass media corresponds the image of nurses in actual life. 4) 74.5% of the subjects said that they got a better image of nurses after their hospitalization while 2% got a worse one and 23.5% said to have had no changes, and the period of hospitalization had no relevance to the image of nurses (X2=5.04, P=.489). However, while 16.8% of the subjects who spent less than one week in hospital said that they got a better image of nurses, 27.5% of those who spent longer than four weeks got a better image of nurses. 5) There was a significant difference in the total image points of nurses by the patients and their guardians according to the period of hospitalization; 4.14 for 1 to 2 weeks, 4.07 for 2 to 4 weeks, 4.02 for 4 weeks and longer and 3.80 for less than a week (F=3.40, P=.019). Upon the results stated above, I should like to propose as below: 1) An investigative enquiry is needed to improve the image of nurses as though being a nurse is very hard and difficult. 2) A continuous monitoring in mass media is needed to create a positive image of nurses.

  • PDF

EARLY DETECTION OF INITIAL DENTAL CARIES USING A $DIFOTI^{TM}$ (Digital Imaging Fiber-Optic Trans-illumination을 이용한 초기 법랑질 우식병소의 조기 진단)

  • Yeom, Hae-Woong;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.587-597
    • /
    • 2004
  • Over the past 20 years, great strides have been made in research regarding the mechanisms involved in the progression of carious lesions, but new equipment and research tools need to be developed to continue these advancements in caries research. Various methods have been applied to reduce the incidence of carious lesions, which have led to a significant decrease in the number of occlusal caries, but a concurrent increase in the proportion of proximal carious lesions. New diagnostic equipment has been developed to detect early stage carious lesions, and these have demonstrated excellent laboratory results and show promise in clinical applications. The research presented here examines the efficacy of the newly developed $DIFOTI^{TM}$ system in detecting proximal carious lesions compared to traditional intraoral exam and bitewing radiography, possible problems or deficiencies of using the system in clinic, possible improvements that can be made to the system, and the efficacy of detecting early, reversible carious lesions that can be remineralized by preventative fluoride applications. The subject pool consisted of 23 grammer school age patients just prior to entering the mixed dentition phase. Each patient was given a thorough oral examination, radiographic examination consisting of bitewing radiographs of the posterior teeth, and $DIFOTI^{TM}$ examination of the anterior and posterior teeth. Each examination was carried out two times by two examiners, and the data were statistically analyzed. The results are as follows: 1. The mean alpha value of reliability test of the visual oral examination was as follows; occlusal surface was 0.8470. mesial surface was 0.6430, distal surface was 0.5727. lingual surface was 0.2807 and distal surface was 0.2339. When the examination was limited to posterior teeth, the mean alpha value was as follows; occlusal surface was 0.8577, distal surface was 0.8211, lingual surface was 0.7728, buccal surface was 0.7152 and mesial surface was 0.6782. 2. The alpha value of reliability test of the radiographic analysis of carious lesions of the occlusal, mesial, and distal surfaces was 0.8500. 3. The alpha value of reliability test of the $DIFOTI^{TM}$ diagnostic analysis of carious lesions of the occlusal, buccal, lingual, mesial, and distal surfaces was determined to be 0.7917. 4. The $DIFOTI^{TM}$ diagnostic system was found to be the most accurate means of detecting occlusal, buccal, and lingual surface carious lesions (p<0.05), while mesial and distal proximal carious lesions were most accurately assessed using bitewing radiography (p<0.05).

  • PDF

Distribution of Taste Receptors in Submandibular and von Ebner Salivary Glands

  • Jun, Yong-Ku;Kim, Se-Nyun;Lee, Cil-Han;Cho, Young-Kyung;Chung, Ki-Myung;Roper, Stephen D.;Kim, Kyung-Nyun
    • International Journal of Oral Biology
    • /
    • v.33 no.1
    • /
    • pp.13-23
    • /
    • 2008
  • Taste is a critically important sense for the survival of an organism. However, structure and distribution of taste receptors were only recently investigated. Although expression of the ion channels responsible for the sense of salty taste and acidity was observed in the non-taste cells, receptors for sweet and bitter taste were only identified in taste cells. Salivary glands are involved in the sensing of taste and plays important roles in the transduction of taste. The purpose of this study is to examine whether taste receptors are present in the salivary glands and to provide clues for the investigation of the taste-salivary glands interaction. Using microarray and RT-PCR analyses, the presence of taste receptor mRNAs in the rat von Ebner gland and submandibular gland was confirmed. Type I taste receptors were preferentially expressed in von Ebner gland, whereas type II taste receptors were expressed in both von Ebner gland and submandibular gland. The tastespecific signal tranducing proteins, $G_{\alpha}gustducin$ and phospholipase C ${\beta}2$, were also detected in both salivary glands by immunohistochemistry. Finally, the activation of the calcium signal in response to bitter taste in the acinar cells was also observed. Taken together, these results suggest that taste receptors are present in the von Ebner gland and submandibular gland and that type II taste receptors are functionally active in both salivary glands.

Preliminary observational results with MIRIS

  • Han, Wonyong;Pyo, Jeonghyun;Kim, Il-Joong;Lee, Dae-Hee;Jeong, Woong-Seob;Moon, Bongkon;Park, Youngsik;Park, Sung-Joon;Lee, Dukhang;Park, Won-Kee;Ko, Kyeongyeon;Kim, Min Gyu;Nam, Uk-Won;Lee, Hyung Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.55.1-55.1
    • /
    • 2015
  • The first Korean infrared space telescope MIRIS (Milti-purpose InfraRed Imaging System) was successfully launched in November 2013, as the main payload of Korean STSAT-3 (Science and Technology Satellite-3). After initial on-orbit operation for verification, the observations have been made with MIRIS for the fluctuation of Cosmic Infrared Background and the Galactic Plane survey. For the study of near-infrared background, MIRIS completed the survey of large areas (> $10^{\circ}{\times}10^{\circ}$ around the pole regions: the north ecliptic pole (NEP), the north and south Galactic poles (NGP, SGP). We are also continuously and frequently monitoring the NEP region for the instrumental calibration and the zodiacal light study. One the other hand, the Paschen-${\alpha}$ Galactic plane survey has been carried out using two narrow-band filters (at $1.88{\mu}m$ and $1.84+1.92{\mu}m$) of MIRIS. This survey is planning to cover the whole Galactic plane with the latitude of ${\pm}3^{\circ}$, and the longitude regions of $+280^{\circ}<l<360^{\circ}$ and $0^{\circ}<l<+210^{\circ}$ have been completed (~ 80%) by February 2015. The data are still under the stage of reduction and analysis, and we present some preliminary results.

  • PDF

The Examination of Reliability of Lower Limb Joint Angles with Free Software ImageJ

  • Kim, Heung Youl
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.6
    • /
    • pp.583-595
    • /
    • 2015
  • Objective: The purpose of this study was to determine the reliability of lower limb joint angles computed with the software ImageJ during jumping movements. Background: Kinematics is the study of bodies in motion without regard to the forces or torques that may produce the motion. The most common method for collecting motion data uses an imaging and motion-caption system to record the 2D or 3D coordinates of markers attached to a moving object, followed by manual or automatic digitizing software. Above all, passive optical motion capture systems (e.g. Vicon system) have been regarded as the gold standards for collecting motion data. On the other hand, ImageJ is used widely for an image analysis as free software, and can collect the 2D coordinates of markers. Although much research has been carried out into the utilizations of the ImageJ software, little is known about their reliability. Method: Seven healthy female students participated as the subject in this study. Seventeen reflective markers were attached on the right and left lower limbs to measure two and three-dimensional joint angular motions. Jump performance was recorded by ten-vicon camera systems (250Hz) and one digital video camera (240Hz). The joint angles of the ankle and knee joints were calculated using 2D (ImageJ) and 3D (Vicon-MX) motion data, respectively. Results: Pearson's correlation coefficients between the two methods were calculated, and significance tests were conducted (${\alpha}=1%$). Correlation coefficients between the two were over 0.98. In Vicon-MX and ImageJ, there is no systematic error by examination of the validity using the Bland-Altman method, and all data are in the 95% limits of agreement. Conclusion: In this study, correlation coefficients are generally high, and the regression line is near the identical line. Therefore, it is considered that motion analysis using ImageJ is a useful tool for evaluation of human movements in various research areas. Application: This result can be utilized as a practical tool to analyze human performance in various fields.

Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth

  • Kamburoglu, Kivanc;Sonmez, Gul;Berktas, Zeynep Serap;Kurt, Hakan;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.109-115
    • /
    • 2017
  • Purpose: The aim of this study was to assess the ex vivo diagnostic ability of 9 different cone-beam computed tomography (CBCT) settings in the detection of recurrent caries under amalgam restorations in primary teeth. Materials and Methods: Fifty-two primary teeth were used. Twenty-six teeth had dentine caries and 26 teeth did not have dentine caries. Black class II cavities were prepared and restored with amalgam. In the 26 carious teeth, recurrent caries were left under restorations. The other 26 intact teeth that did not have caries served as controls. Teeth were imaged using a $100{\times}90-mm$ field of view and a 0.2-mm voxel size with 9 different CBCT settings. Four observers assessed the images using a 5-point scale. Kappa values were calculated to assess observer agreement. CBCT settings were compared with the gold standard using a receiver operating characteristic analysis. The area under the curve (AUC) values for each setting were compared using the chi-square test, with a significance level of ${\alpha}=.05$. Results: Intraobserver kappa values ranged from 0.366 to 0.664 for observer 1, from 0.311 to 0.447 for observer 2, from 0.597 to 1.000 for observer 3, and from 0.869 to 1 for observer 4. Furthermore, interobserver kappa values among the observers ranged from 0.133 to 0.814 for the first reading and from 0.197 to 0.805 for the second reading. The highest AUC values were found for setting 5 (0.5916) and setting 3 (0.5886), and were not found to be statistically significant(P>.05). Conclusion: Variations in tube voltage and tube current did not affect the detection of recurrent caries under amalgam restorations in primary teeth.

Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

  • Rovaris, Karla;de Faria Vasconcelos, Karla;do Nascimento, Eduarda Helena Leandro;Oliveira, Matheus Lima;Freitas, Deborah Queiroz;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • v.46 no.4
    • /
    • pp.239-244
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Materials and Methods: Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self­administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (${\alpha}=0.05$). results: A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p = 0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. conclusion: This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

TRPM7 Is Essential for RANKL-Induced Osteoclastogenesis

  • Yang, Yu-Mi;Jung, Hwi-Hoon;Lee, Sung Jun;Choi, Hyung-Jun;Kim, Min Seuk;Shin, Dong Min
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2013
  • The transient receptor potential melastatin type 7 (TRPM7) channel is a widely expressed non-selective cation channel with fusion to the C-terminal alpha kinase domain and regarded as a key regulator of whole body $Mg^{2+}$ homeostasis in mammals. However, the roles of TRPM7 during osteoclastogenesis in RAW264.7 cells and bone marrow-derived monocyte/macrophage precursor cells (BMMs) are not clear. In the present study, we investigate the roles of TRPM7 in osteoclastogenesis using methods of small interfering RNA (siRNA), RT-PCR, patch-clamp, and calcium imaging. RANKL (receptor activator of NF-${\kappa}B$ ligand) stimulation did not affect the TRPM7 expression and TRPM7-mediated current was activated in HEK293, RAW264.7, and BMM cells by the regulation of $Mg^{2+}$. Knock-down of TRPM7 by siTRPM7 reduced intracellular $Ca^{2+}$ concentration ($[Ca^{2+}]_i$) increases by 0 mM $[Mg^{2+}]_e$ in HEK293 cells and inhibited the generation of RANKL-induced $Ca^{2+}$ oscillations in RAW264.7 cells. Finally, knock-down of TRPM7 suppressed RANKL-mediated osteoclastogenesis such as activation and translocation of NFATc1, formation of multinucleated cells, and the bone resorptive activity, sequentially. These results suggest that TRPM7 plays an essential role in the RANKL-induced $[Ca^{2+}]_i$ oscillations that triggers the late stages of osteoclastogenesis.

Radiation for persistent or recurrent epithelial ovarian cancer: a need for reassessment

  • Choi, Noorie;Chang, Ji Hyun;Kim, Suzy;Kim, Hak Jae
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.144-152
    • /
    • 2017
  • Purpose: The role of radiotherapy (RT) was largely deserted after the introduction of platinum-based chemotherapy, but still survival rates are disappointingly low. This study focuses on assessing the clinical efficacy of RT in relation to chemotherapy resistance. Materials and Methods: From October 2002 to January 2015, 44 patients were diagnosed with epithelial ovarian cancer (EOC) and treated with palliative RT for persistent or recurrent EOC. All patients received initial treatment with optimal debulking surgery and adjuvant platinum-based chemotherapy. The biologically effective dose (BED) was calculated with ${\alpha}/{\beta}$ set at 10. Ninety-four sites were treated with RT with a median BED of 50.7 Gy (range 28.0 to 79.2 Gy). The primary end-point was the in-field local control (LC) interval, defined as the time interval from the date RT was completed to the date any progressive or newly recurring disease within the RT field was detected on radiographic imaging. Results: The median follow-up duration was 52.3 months (range 7.7 to 179.0 months). The 1-year and 2-year in-field LC rates were 66.0% and 55.0%, respectively. Comparisons of percent change of in-field tumor response showed similar distribution of responses among chemoresistant and chemosensitive tumors. On multivariate analysis of predictive factors for in-field LC analyzed by sites treated, $BED{\geq}50Gy$ (hazard ratio, 0.4; confidence interval, 0.2-0.9; p = 0.025) showed better outcomes. Conclusion: Regardless of resistance to platinum-based chemotherapy, RT can be a feasible treatment modality for patients with persistent of recurrent EOC. The specific role of RT using updated approaches needs to be reassessed.