• Title/Summary/Keyword: Alloy steel pipe

Search Result 30, Processing Time 0.027 seconds

Design and Manufacture of CFRP Pipe for Bicycle Frame (자전거 프레임용 CFRP 파이프 설계제작)

  • 이범성
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.130-137
    • /
    • 2003
  • The pipe of CFRP for bicycle frame is designed and made for light weight of bicycle and then its suitability to bicycle frame is verified by comparing the other material i.e. steel, Cr-Mo steel, Al alloy pipe for bicycle frame. The pipe of CFRP is laminated to [0/$\pm$45]$_T$ and made by tape winding method and then its degree of light weight is evaluated by comparing the other pipes which is made by steel etc.

Effects of alloys and flow velocity on welded pipeline wall thinning in simulated secondary environment for nuclear power plants (원전 2차계통수 모사 환경에서 용접배관 감육 특성에 미치는 재료 및 유속의 영향)

  • Kim, Kyung Mo;Choeng, Yong-Moo;Lee, Eun Hee;Lee, Jong Yeon;Oh, Se-Beom;Kim, Dong-Jin
    • Corrosion Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.245-252
    • /
    • 2016
  • The pipelines and equipments are degraded by flow-accelerated corrosion (FAC), and a large-scale test facility was constructed for simulate the FAC phenomena in secondary coolant environment of PWR type nuclear power plants. Using this facility, FAC test was performed on weld pipe (carbon steel and low alloy steel) at the conditions of high velocity flow (> 10 m/s). Wall thickness was measured by high temperature ultrasonic monitoring systems (four-channel buffer rod type and waveguide type) during test period and room temperature manual ultrasonic method before and after test period. This work deals with the complex effects of flow velocity on the wall thinning in weld pipe and the test results showed that the higher flow velocity induced different increasement of wall thinning rate for the carbon steel and low alloy steel pipe.

Seismic response of steel braced frames equipped with shape memory alloy-based hybrid devices

  • Salari, Neda;Asgarian, Behrouz
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.1031-1049
    • /
    • 2015
  • This paper highlights the role of innovative vibration control system based on two promising properties in a parallel configuration. Hybrid device consists of two main components; recentering wires of shape memory alloy (SMA) and steel pipe section as an energy dissipater element. This approach concentrates damage in the steel pipe and prevents the main structural members from yielding. By regulation of the main adjustable design parameter, an optimum performance of the device is obtained. The effectiveness of the device in passive control of structures is evaluated through nonlinear time history analyses of a five-story steel frame with and without the hybrid device. Comparing the results proves that the hybrid device has a considerable potential to mitigate the residual drift ratio, peak absolute acceleration and peak interstory drift of the structure.

Influence of ultrasonic impact treatment on microstructure and mechanical properties of nickel-based alloy overlayer on austenitic stainless steel pipe butt girth joint

  • Xilong Zhao;Kangming Ren;Xinhong Lu;Feng He;Yuekai Jiang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4072-4083
    • /
    • 2022
  • Ultrasonic impact treatment (UIT) is carried out on the Ni-based alloy stainless steel pipe gas tungsten arc welding (GTAW) girth weld, the differences of microstructure, microhardness and shear strength distribution of the joint before and after ultrasonic shock are studied by microhardness test and shear punch test. The results show that after UIT, the plastic deformation layer is formed on the outside surface of the Ni-based alloy overlayer, single-phase austenite and γ type precipitates are formed in the overlayer, and a large number of columnar crystals are formed on the bottom side of the overlayer. The average microhardness of the overlayer increased from 221 H V to 254 H V by 14.9%, the shear strength increased from 696 MPa to 882 MPa with an increase of 26.7% and the transverse average residual stress decreased from 102.71 MPa (tensile stress) to -18.33 MPa (compressive stress), the longitudinal average residual stress decreased from 114.87 MPa (tensile stress) to -84.64 MPa (compressive stress). The fracture surface has been appeared obvious shear lip marks and a few dimples. The element migrates at the fusion boundary between the Ni-based alloy overlayer and the austenitic stainless steel joint, which is leaded to form a local martensite zone and appear hot cracks. The welded joint is cooled by FA solidification mode, which is forming a large number of late and skeleton ferrite phase with an average microhardness of 190 H V and no obvious change in shear strength. The base metal is all austenitic phase with an average microhardness of 206 H V and shear strength of 696 MPa.

Effect of Loading Rate on the Deformation Behavior of SA508 Gr.1a Low Alloy Steel and TP316 Stainless Steel Pipe Materials at RT and 316℃ (상온과 316℃에서 SA508 Gr.1a 저합금강 배관과 TP316 스테인리스강 배관의 변형거동에 미치는 하중속도의 영향)

  • Kim, Jin Weon;Choi, Myung Rak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.383-390
    • /
    • 2015
  • This study conducted tensile tests on SA508 Gr.1a low alloy steel and SA312 TP316 stainless steel piping materials under various strain rates at room temperature (RT) and $316^{\circ}C$ to investigate the effects of loading rate on the deformation behavior of nuclear piping materials. At RT, the deformation behavior for both pipe materials showed a typical loading rate dependence, i.e., the strength increased and the ductility decreased as the loading rate increased. At $316^{\circ}C$, however, the strength and elongation of SA508 Gr.1a low alloy steel decreased as the loading rate increased, and its reduction of area non-linearly varied with the loading rate. For SA312 TP316 stainless steel, the strength, elongation, and reduction of area at $316^{\circ}C$ were almost the same regardless of the loading rate. At both temperatures, the strain hardening capacity was nearly independent of the loading rate for SA508 Gr.1a low alloy steel, while it decreased with increasing loading rate for SA312 TP316 stainless steel.

Evaluation of Mechanical Properties with Thermal Aging in CF8M/SA508 Welds (CF8M과 SA508 용접재의 열화거동과 기계적특성 평가)

  • 우승완;최영환;권재도
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1968-1973
    • /
    • 2004
  • Structural degradations are often experienced on the components of nuclear power plants in reactor pressure vessels (RPV) and steam generators (SG) when these components are exposed to high temperature and high pressure for a long period of time. Such conditions result in the change of microstructures and of mechanical properties of materials, which requires an evaluation of the safeguards related to structural integrity. In a primary reactor cooling system (RCS), a dissimilar weld zone exists between cast stainless steel (CF8M) in a pipe and low-alloy steel (SA508 cl.3) in a nozzle. Thermal aging is observed in CF8M as the RCS is exposed for a long period of time under the operating temperature between 290 and 33$0^{\circ}C$. Under the same conditions, it is well known that degradation is not observed in low alloy steel. An investigation of the effect of thermal aging on the various mechanical properties of the dissimilar weld zone is required. The purpose of the present investigation is to find the effect of thermal aging on the dissimilar weld zone. The specimens are prepared by an artificially accelerated aging technique maintained for various times at 43$0^{\circ}C$, respectively. Then, The various mechanical test for the dissimilar welds are performed.

Effect of $N_2$ back shielding gas on the property change of GTA weldment (질소 이면보호가스 적용성에 관한 연구)

  • 백광기;안병식
    • Journal of Welding and Joining
    • /
    • v.5 no.4
    • /
    • pp.12-21
    • /
    • 1987
  • To investigate the suitability of nitrogen gas as an internal purging gas, various properties of GTA welded joints of duplex, 316L stainless steel, Cu-Ni alloy pipe using nitrogen purging gas were evaluated with reference to onew purged with argon gas. Mechanical properties evaluated by the tensile, bending test, and hardness value of welded joints with nitrogen gas purging did not show any difference those with argon gas. General and local corrosion rates of each welded joint prepared by nitrogen gas purging also showed no difference with those prepared by argon gas. Based on the present test results it is confirmed that nitrogen is a suitable purging gas for GTA welding of stainless steels and nonferrous piping systems, which can be used at lower cost instead of argon.

  • PDF

Analysis of Thermal Cycles and Microstructure of Heat Affected Zone for a Low Alloy Carbon Steel Pipe under Multipass Weld (저합금 탄소강 배관재의 다층용접 열영향부의 미세조직 및 열이력 해석)

  • Kim, Tae-Wan;Ha, Jun-Uk;Kim, Dong-Jin;Kim, Jeong-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.3
    • /
    • pp.497-504
    • /
    • 2002
  • The purpose of this study is to analyze thermal cycles and to investigate microstructures of heat affected zones for a low alloy carbon steel pipe under a multipass weld. The commercial finite element code SYSWELD is used to compute thermal cycles during multipass weld. The numerical results such as thermal cycles and size of heat affected zone are compared with those of the experiment and the two results show a good agreement. In addition, the microstructure and hardness are investigated from the weldment in detail. The weakest location is founded at intercritical region near the base metal.