원전 엘보우의 성능기반 안전여유도 분석 (Investigation of the Performance Based Structural Safety Factor of Elbows in Nuclear Power Plants)

  • 이성호;박치용;박재학
    • 대한기계학회논문집A
    • /
    • 제33권8호
    • /
    • pp.826-831
    • /
    • 2009
  • The piping systems in nuclear power plant are composed of various typed pipes such as straight, elbow pipe, branch and reducer etc. The elbow is connected from straight pipe to another pipes in order to establish the complicated piping system. Elbow is one of very important components considering management of wall thinning degradation. It is however applied by various loads such as system pressure, earthquake, postulated break loading and many transient loads, which provoke simply the internal pressure, bending and torsional stress. In this study, firstly pipes in the secondary system of the nuclear power plant are classified as pipe size and type for selecting the investigating range. Next, a large number of finite element analysis considering the all typed dimensions of commercial pipe has been performed to find out the behavior of TES(twice elastic slop) plastic load of elbows, which is based on evaluation of the structural safety factor. Finally performance based structural safety factor was investigated comparing with maximum allowable load by construction code.

내압과 굽힘하중하에서 감육배관의 국부허용두께 평가 (Evaluation of Local Allowable Wall Thickness of Thinned Pipe Subjected to Internal Pressure and Bending Moment)

  • 김진원;박치용;김범년
    • 대한기계학회논문집A
    • /
    • 제25권1호
    • /
    • pp.81-88
    • /
    • 2001
  • This study proposed an analytical method to evaluate a local allowable wall thickness (LAWT) for locally thinned pipe subjected to internal pressure and bending moment. In this method, the stresses in the thinned region were calculated by finite element analysis and plastic collapse was applied as a failure criterion of thinned pipe. Using this method, LAWT for a simplified thinned pipe was evaluated with variation in axial extent of thinned area, and it was compared with allowable wall thickness provided by previous pipe wall thickness criteria. The results showed that the LAWT was lower, about 50%, than that calculated by construction code or ASME Code N-597, and it was higher, about 2 times, than that estimated by evaluation model based on pipe experiments. In addition, LAWT was decreased with increasing axial extent of thinned area and saturated with further increase in axial extent. And, the variation in LAWT with axial extent of thinned area depended on type of load, especially a magnitude of bending moment, considering in the evaluation.

한계상태설계법에 의한 기존 강박스거더교의 내하력 환산 (A Conversion of Load Carrying Capacity for Existing Steel Box Girder Bridge Based on Limit State Design Method)

  • 노동오;경갑수;박진은
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.89-96
    • /
    • 2018
  • 교량 시설물은 사회적으로 중요한 기반 시설물로서 공용기간 동안 안전한 관리가 중요하다. 도로교량의 많은 비율을 차지하고 있는 강박스거더교량의 경우 허용응력설계법으로 설계되고 내하력이 평가되어 왔으나, 최근 한계상태설계법으로 설계기준이 변경되었음에도 불구하고 내하력 평가에서는 아직까지 허용응력법을 대부분 사용하고 있는 실정이다. 이에 이 연구에서는 2 가지 설계 방법을 이용하여 다수의 교량에 대한 내하율 평가 결과를 비교하고, 기존의 허용응력법에 의한 내하력을 한계상태법에 의한 내하력으로 환산하는 방법을 모색하고자 하였다. 이 결과는 추후 교량을 관리함에 있어 보강 필요성 판단 및 한계상태법에 의한 내하력 평가에 기초자료로 활용될 수 있을 것으로 기대된다.

사질토를 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(VI) - 지반의 허용압축지지력 산정용 표해 또는 도해 - (A Study(VI) on the Development of Charts and Equations Predicting Bearing Capacity for Prebored PHC Piles Socketed into Weathered Rock through Sandy Soil Layers - Axial Compressive Bearing Capacity Prediction Table Solution or Chart Solution -)

  • 남문석;권오균;박민철;이창욱;최용규
    • 한국지반공학회논문집
    • /
    • 제35권11호
    • /
    • pp.75-95
    • /
    • 2019
  • 본 연구에서는 사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에 대한 수치해석 결과를 분석하여 정리한 도표 또는 도해로부터 매입 PHC말뚝의 동원지지력을 구하는 방법을 제안하였다. 즉, 수치해석 결과인 하중-침하량 곡선에서 5% 직경에 해당하는 침하량에서 발현된 사질토층의 동원주면마찰력, 풍화암층의 동원주면마찰력과 동원선단지지력을 산정할 수 있는 표해 또는 도해를 제안하였다. 이때 허용압축지지력은 동원 지지력에 안전율 3.0을 적용하여 산정하였다. 사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝의 허용압축지지력은 사질토층의 허용주면마찰력과 풍화암층의 허용주면마찰력 및 허용선단지지력을 합산하여 산정하는 것으로 제안하였고, 각 허용압축지지력 성분을 구할 수 있는 절차도 제시되어 있다. 본 연구에서 제안된 동원지지력 산정용 표해(또는 도해)를 사용할 경우, 적정 설계에서 PHC말뚝의 설계효율(DE)은 85%로 나타났으며, 따라서 최적 설계에서는 PHC말뚝의 장기허용압축하중(Pall) 까지도 활용할 수 있는 것으로 나타났다. 그리고 PHC말뚝의 우수한 압축하중 지지 성능을 효과적으로 활용하기 위하여 지반의 허용압축지지력(Qall)이 말뚝의 허용압축하중(Pall) 이상이 될 수 있도록 설계할 것을 권장하였다.

Design loads for floating solar photovoltaic system: Guide to design using DNV and ASCE standards

  • Gihwan Kim;Moonsu Park
    • Structural Engineering and Mechanics
    • /
    • 제89권2호
    • /
    • pp.171-179
    • /
    • 2024
  • The market of the floating solar photovoltaic system is rapidly growing around the world with the rise of renewable energy that can replace fossil energy. While the floating solar photovoltaic system is operating and being installed in several countries, the system is exposed to the risk in terms of structural safety due to the absence of the proper design guideline. In this paper, design loads suitable for the floating solar photovoltaic system are presented. Utilizing the existing reliable design standards such as ASCE 7-16 (ASCE 7-16 2016) and DNV-RP-C205 (DNV-RP-C205 2010), the appropriate design loads for the floating solar photovoltaic system are presented. The proper load combinations are also presented by putting wave load based on DNV standards (DNV-OS-C101 2015 and DNV-OS-C201 2015) into the load combinations in ASCE standards (ASCE 7-16 2016). We present the load combinations for the allowable stress design and load and resistance factor design, respectively.

관입말뚝에 대한 연직재하시험시 항복하중의 판정법 (Evaluation of Yield Load in Pile Load Tests on Driven Piles)

  • 홍원표;심기석
    • 한국지반공학회지:지반
    • /
    • 제5권1호
    • /
    • pp.7-18
    • /
    • 1989
  • 암반에 지지된 선단지지맡뚝에 대한 연직재하시험시, 극한하중에 이르기까지 재하를 실시하는 것은 일반적으로 불가능하다. 이러한 경우 말뚝재하시험결과로부터 설계하중을 결정하기 위하여 봉복 윤중의 개념이 도입되어 오고 있다. 그러나, 이 강복초중을 결정하기가 용이하지 않은 경우가 많다. 본 논문에서는 우리나라 서해안과 남해안 지대 6개 현장에서 실시된 말뚝재하시험결과를 검토분 석하여 항복하중을 쉽게 결정할 수 있는 새로운 방법을 제안하였다. 이 방법에서 강복하대은 말뚝의 침하량을 대수눈금으로, 하중을 정규눈금으로 한 반대수응지상에 정리된 하중과 침하량 체선(P- log영상의 변곡점으로 정의되었다. 이 방법에 의한 강복연동보다 약간 많은 하중까지 재하시험을실 기하므로써, 말뚝재하시험의 비용과 시간을 절약할 수 있을 뿐만 아니라 안전한 작업조건도 마련할 수 있다. 이 강복하중은 하중과 침하량 거동의 탄성한계를 규정짓는 하중이 됨을 알 수 있었다. 25.4 mm침하시의 하중으로 결정되는 식한하동은 이 강복륜중의 1.i배에 해당하였으며 장기 및 단기 허 용하중은 각각 이 항복하중의 50%와 75%에 해당하였다. 또한 정역학적 지지력공식을 사용하여 허 용지지력을 구할 경우 안전율은 2.0~4.0으로 밝혀졌다.

  • PDF

생태축조블록의 국부적 안정성에 관한 실험적 연구 (An Experimental Study on Local Stability of Eco-block)

  • 이승현;이수형
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2866-2871
    • /
    • 2011
  • 본 연구에서는 생태축조블록을 적용한 보강토 옹벽의 국부적 안정성 검토에 필요한 보강재 인장력 계산법을 정립하고 국부적 안정성 검토와 관련한 주요 설계인자인 보강재와 블록 사이의 연결강도와 블록 접촉면 사이의 전단강도를 시험을 통해 규명하였다. 연결강도 시험결과에 따르면 생태축조블록의 내부를 흙으로 속채움하고 D13 이형철근을 사용할 경우 첨두 하중값은 이형철근의 허용인장력 정도임을 알 수 있었으며 D16 이형철근을 사용할 경우 첨두하중값은 허용인장력의 76% 정도였다. 생태축조블록의 내부를 콘크리트로 속채움하는 경우에 있어서 D10, D13 이형철근을 사용하였을 때의 연결강도는 각각의 이형철근의 허용인장력보다 크게 나타났다. 생태축조블록의 접촉면 전단시험결과를 통해 구한 전단저항 매개변수인 ${\alpha}_u$는 1.7kN/m 이었고 ${\lambda}_u$$27.6^{\circ}$ 이었다.

고속철도 레일 표면 결함 관리기준에 관한 연구 (Investigation of the Maintenance Criteria for the Rail Surface Defects in High-Speed Railways)

  • 양신추;장승엽
    • 한국철도학회논문집
    • /
    • 제14권6호
    • /
    • pp.535-544
    • /
    • 2011
  • 레일 표면 결함이 발생할 경우 매우 높은 충격하중이 발생하여 레일 피로 진전 또는 레일 파단에 이를 수 있고 레일이 파단될 경우 열차탈선 등 대형 사고가 발생할 수 있으므로 레일 결함부에 대한 관리기준의 정립이 매우 중요하다. 본 연구에서는 차량-궤도 동적 상호작용 해석 프로그램을 이용하여, 실제 고속철도 자갈궤도에서 결함이 발생한 43개 지점에서 측정된 레일요철을 입력값으로 하여, 요철 깊이에 따른 충격 윤중과 레일 휨응력을 산정하였다. 궤도틀림을 감안하여 윤중 및 레일 휨응력의 한계값을 설정하고, 해석결과로부터 얻은 윤중 및 레일 휨응력 최대값과 결함 깊이 및 폭과의 상관관계를 분석함으로써 레일 표면 결함부에 대한 관리기준을 제시하였다. 분석 결과, 허용할 수 있는 요철 깊이는 충격 윤중에 의하여 발생할 수 있는 레일 두부의 소성 변형을 방지하기 위하여 관리되어야 하며, 엄격한 조건을 평가할 경우 그 값은 0.2mm 정도가 적당함을 알 수 있었다.

Geogrid로 보강된 점토지반에 축조된 대상기초의 반복하중하에서의 침하거동 (Settlement Behavior of Strip Foundation on Geogrid Reinforced Clay under Cyclic Loading)

  • 신은철;다스브라지앰
    • 한국지반공학회지:지반
    • /
    • 제11권3호
    • /
    • pp.27-36
    • /
    • 1995
  • 지오흐리드로 보강된 포화점토상에 축조된 줄기초가 낮은 빈도의 반복하중을 받았을시 발생 되는 열구침하량을 산정하기위한 실내모형 실험을 실시하였다. 실험을 실시하는 과정에서 초기 단계에는 기초에 허용정적 하중을 가하였고 연속적으로 반복하중을 가하였다. 정적하중과 반복 하중강도에 따른 기초의 최대영구침하량에 관하여 기술하였다.

  • PDF

배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출 (The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems)

  • 김미영
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.