• 제목/요약/키워드: Allowable Value

검색결과 307건 처리시간 0.029초

벼의 충격(衝擊) 특성(特性)에 관한 연구(硏究) (Measurements of Mechanical Behavior of Rough Rice under Impact Loading)

  • 차재윤;고학균;노상하;김만수;김용현
    • Journal of Biosystems Engineering
    • /
    • 제14권3호
    • /
    • pp.207-214
    • /
    • 1989
  • In this study, impact force and angular displacement of the pendulum were measured by the load cell and potentiometer. Mechanical behavior of rough rice under impact loading was able to analyze precisely and efficiently, because measured data were accumulated and handled by the automatic data acquisition system making use of microcomputer system. Impact force and angular displacement were measured with a resolutiln of 1/1500 seconds in time. Mechanical behavior such as force and energy at rupture point of Japonica type and Indica type rough rice were measured with this system. After impact loading, the damage of rough rice was examined with the microphotograph and an allowable impact force was measured. The results obtained in this study are summarized as follows. 1. Machanical behavior of rough rice under impact loading was analyzed precisely and efficiently because measured data were accumulated and handled by this data acquisition system. 2. Rupture force and rupture energy of rough rice were appeared to be the lowest value in the range of 16 to 18 % moisture content, and rupture force and rupture energy of Japonica type were higher than those of Indica type in each level of moisture content. 3. From the result of the damage examined after the impact loading, allowable impact force was the lowest in the range of 16 to 18 % moisture content, and the value of the allowable impact force of Japonica type was higher than that of Indica type in each level of moisture content.

  • PDF

부산 통신구굴진 발파작업으로 인한 지상주택 구조물에 미치는 진동폭음영향계측조사보고 (On the study of the measurement of blasting Vibration and Sound influenced to housing structure at Wire-Tunnelling)

  • 허진
    • 화약ㆍ발파
    • /
    • 제8권2호
    • /
    • pp.3-17
    • /
    • 1990
  • The Caustious blasting have often increased Complaints of ground Vibration and Sound when the Wire-Tunnel Constructed in Pusan. In order to prevent the influence to housing structure, it was necessary to predict blasting-Induced Vibration and Sound. The Suveyer determined the Burden and spacing of Drill holes, minimum delay charges within a allowable Vibration and Sound Level. Tunnel drilling and Ignition patterns are made as follows; No. 1 Tunel (Stable rock, hard rock) No.2 Tunnel (Instable plastic rock; wethered rock) and other Tunnels (Instable rock). The result of 1st testing blasting of No. 1 Tunnel was recorded Under allowable Vibration Level but sound was over 75 Db of allowable value. So Tunnel drilling pattern was amended with 52 Non-charg holes to reduce the blast-sound. The other pattern had no need to amend.

  • PDF

허용하중집합 개념을 이용한 기계/구조 시스템의 강건 설계 (Robust Design of Structural and Mechanical Systems using Concept of Allowable Load Set)

  • 곽병만
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.333-338
    • /
    • 2007
  • The concept of "Allowable Load Set (ALS)" introduced by the author allows an easy understanding of load and strength characteristics of a structure in relation to its integrity under uncertainties. Two criteria of safety are introduced: A relative safety index denotes the distance to the boundary of the ALS and a normalized safety index is a distance in terms of functional value. They have been utilized in several examples, including multi-body mechanical systems such as a biomechanical system. Both formulations amount to robust designs in the sense that designs most insensitive to uncertainties are obtained in the context of newly defined safety indices, without using any input probability information.

  • PDF

도심지 소유역에 적용 가능한 우수저류조의 용량 산정에 관한 연구 (A Study on the Calculation of Storage Volume of Storm-Water Detention Basins for Small Urban Catchments)

  • 김대근;고영찬
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.619-624
    • /
    • 2005
  • This work is for examining a simplified equation based on the rational formula, which can easily decide storm-water detention volume in small urban catchments. The storm-water detention volume is determined by the inflow hydrograph flowing to detention basin and the outflow hydrograph discharged from the detention basin. The ratio of average outflow over the period of rainfall duration against allowable discharge was 0.5 in former simplified equation. But this research has found that the average outflow ratio depends on the storage methodology. In the case of the on-line storage method, the average outflow ratio is a function of the time of concentration of the catchments and rainfall duration, which ranged from 0.5~1.0. In the case of the off-line storage method, the average ratio is a function of peak discharge and allowable discharge except above time of concentration and rainfall duration, where its function value ranged from 1.0~2.0. When applying this equation to small catchment in Mokpo city, South Korea, we could easily calculate the relation curve between the storm-water detention volume and allowable discharge.

화력발전용 증기터빈 밸브 케이싱의 수명 설계를 위한 최대허용온도차 계산 (Calculation of Maximum Allowabel Temperature Difference for Life Design of Valve Casings for Steam Turbines of Fossil Power Plants)

  • 하준욱;김태완;이부윤
    • 한국정밀공학회지
    • /
    • 제16권8호
    • /
    • pp.46-52
    • /
    • 1999
  • Large valves for steam turbines of fossil power plants are exposed to a severe mechanical and thermal loading resulting from steam with high pressure and high temperature. Valve casings are designed to withstand such a loading. During the operation of a plant, temperatures at inner and outer surface of the casings are measured and steam flow is controlled so that the measured difference is lower than the maximum allowable value determined in the design stage. In this paper, a method is presented to calculate the maximum allowable temperature difference at the inner and outer surface of valve casings for steam turbines of fossil power plants. The finite element method is used to analyze distribution of temperature and stresses of a casing under the operating condition. Low cycle fatigue and creep rupture are taken into consideration to determine the maximum allowable temperature difference. The method can be usefully applied in the design stage of the large valves for the steam turbines, contributing to safe and reliable operation of the fossil power plants.

  • PDF

H-pile의 지지력 특성 및 동역학적 공식의 신뢰도 평가 (Characteristics of Bearing Capacity and Reliability-based Evaluation of Pile-Driving Formulas for H Pile)

  • 오세욱;이준대
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.81-88
    • /
    • 2003
  • Recently, pile foundations were constructed in rough or soft ground than ground of well condition thus it is important that prediction of ultimate bearing capacity and calculation of proper safety factor applied pile foundation design. This study were performed to dynamic loading tests for the thirty two piles at four different construction sites and selected pile at three site were performed to static loading tests and then compare with measured value and value of static and dynamic loading tests. The load-settlement curve form the dynamic loading tests by CAPWAP was very similar to the results obtained from the static load tests. Based on dynamic and static loading tests, the reliability of pile-driving formula were analyzed and then suggested with proper safety factor for prediction of allowable bearing capacity in this paper.

고속탈출유도로 최소 갯수 및 위치 결정 모형 (A Model for Determining the Minimum Number of High Speed Exits and Their Locations for Airports)

  • 김병종
    • 대한교통학회지
    • /
    • 제13권3호
    • /
    • pp.53-65
    • /
    • 1995
  • Proposed are model and its solution algorithm for determining the minimum number of high speed exits and their locations. While the previous researches on exit location aimed to minimize the average runway occuancy time (ROT) of an aircraft mix, the proposed approach is to find the minimum number of exits required to meet maximum allowable ROT. The rationale behind the approach is that the capacity of a runway increases as the ROT decreases down to some value, but not any more even though the ROT keep decreasing below the value. Hence, a maximum allowable ROT might be set up without declining the capacity. The problem is transformed into a shortest path problem on a specially constructed network and Dijkstra's labeling algorithms is employed to solve the problem A hypothetical example is provided to illustrate how the algorithms solves the problem.

  • PDF

Profibus 성능 모델에서 최대 허용 전송 지연을 만족할 수 있는 타이머 선정에 관한 연구 (Timer Selection for Satisfying the Maximum Allowable Delay using Performance Model of Profibus Token Passing Protocol)

  • 김현희;이경창;이석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2003
  • Recently, the fieldbus becomes an indispensable component for many automated systems. In the fieldbus system, realtime data containing sensor values and control commands has a tendency to rapidly lose its value as time elapses after its creation. In order to deliver these data in time, the fieldbus network should be designed to have short delay compared to the maximum allowable delay. Because the communication delay is affected by performance parameters such as target rotation timer of token passing protocol, it is necessary to select proper parameter settings to satisfy the real-time requirement for communication delay. This paper presents the timer selection method for Profibus token passing networks using genetic algorithm (GA) to meet the delay requirements.

  • PDF

CONSTRAINED DEFUZZIFICATION

  • Yager, Ronald R.;Filev, Dimitar P.
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1993년도 Fifth International Fuzzy Systems Association World Congress 93
    • /
    • pp.1167-1170
    • /
    • 1993
  • We look at the problem of defuzzification in situations in which in addition to the usual fuzzy output of the controller there exists some ancillary restriction on the allowable defuzzified values. We provide two basic approaches to address this problem. In the first approach we enforce the restriction by selecting the defuzzified value through a random experiment in which the values which have nonzero probabilities are in the allowable region, this method is based on the RAGE defuzzification procedure and makes use of a nonmonotonic conjunction operator. The second approach which in the spirit of the commonly used methods, a kind of expected value, converts the problem to a constraint optimization problem.

  • PDF

Study of the Distribution Properties and LRFD Code Conversion in Japanese Larch

  • Park, Chun-Young;Pang, Sung-Jun;Park, Ju-Sang;Kim, Kwang-Mo;Park, Mun-Jae;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권2호
    • /
    • pp.94-100
    • /
    • 2010
  • This study was performed to develop an LRFD (Load Resistance Factored Design) Code for Domestic Larch. To accomplish his, we evaluated bending, compression, tension and shear strength. The results of the strength evaluation were utilized to verify the distribution and code conversion. For bending, tension and compressive strength, the Weibull distribution was well-fitted, but for shear strength we observed a normal distribution. For evaluating the bending and compressive strength, a full-sized specimen was used. A small clear specimen was used to test tension and shear strength. Compressive strength in particular was found to be affected by tight knots, although there was little difference between grades. In the code conversion, the design value of the LRFD was larger than the existing allowable stress value in the Korean Building Code. However, the allowable stress in this study was about two times higher than the value listed in the Korean Building Code. This result induced the difference between the soft and hard conversions. For greater reliability, the accumulation of additional data is necessary and further studies should be performed