• Title/Summary/Keyword: Allowable Risk

Search Result 57, Processing Time 0.024 seconds

Environmental Fatigue Evaluation of Top-Mounted In-Core Instrumentation Nozzle (상부 탑재형 노내계측기 노즐의 환경피로평가)

  • Yoon, Hyo-Sub;Kim, Jong-Min;Maeng, Cheol-Soo;Kim, Gee-Seok;Kim, Hyun-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.245-252
    • /
    • 2016
  • The development of Top-Mounted In-Core Instrumentation(TM-ICI) is an ongoing project to reduce the risk due to severe accidents by inserting the instrumentation into a reactor closure head instead of a reactor bottom head. As part of this project, environmental fatigue analyses for TM-ICI nozzle have been performed using two methods of NUREG/CR-6909 and Code Case N-761. TM-ICI nozzle is subjected to transient loads for level A, level B and test conditions that should be evaluated for a fatigue analysis. It is found that a cumulative usage factor considering reactor coolant environment for TM-ICI nozzle is evaluated as less than 1, which is ASME Code allowable criteria of a fatigue analysis.

Assessment on Navigational Stress and Fairway' Width according to Traffic Flow (교통용량에 따른 운항위험도와 항로폭과의 관계에 관한 연구)

  • Seong, Yu-Chang
    • Journal of Navigation and Port Research
    • /
    • v.38 no.3
    • /
    • pp.253-259
    • /
    • 2014
  • Traffic risks in fairway and harbour area increase lately according to be a sharpe change of ship's size and speed. It becomes hot issue to design a fairway, which's width is important to lower traffic risk and ensure navigational safety. The current design making a fairway and width do not focus on maneuvering motion of a large ship, but traffic risks are clear on reflecting the design of fairway, specially on width. To contact with these problems, this research proposes how to determine fairway' width in consideration of traffic volume. it suggests several situations of marine traffic congestion as like narrow channel and harbour area. here uses 162 simulations in MTS Ver.1 developed. Acquired simulation's results, environmental stress dates, figure in a model that relates with required fairway' width and allowable traffic volume. In added, suggested model compares current design with an width.

A Study on the Lateral Movement of Bridge Abutment Using Centrifuge Test and Numerical Analysis (원심모형시험과 수치해석을 이용한 교대 측방유동에 관한 연구)

  • Yoo, Wan-Kyu;Kim, Ki-Il;Kim, Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1799-1804
    • /
    • 2010
  • In regard to fill loading structures such as bridge abutments and retaining walls on soft ground, the soft ground undergoes excessive deformation, which causes the lateral movement of the ground, resulting in increased risk of much damage. In this study, a centrifuge model test was conducted to check the possibility of lateral movement of a bridge abutment during back filling in a field, and a numerical analysis considering the lateral movement of the bridge abutment under the influence of the counterweight fill method applied during construction was carried out by using MIDAS/GTS as the FEM(Finite Element Method) program. The results of this study showed that the lateral movement of the abutment can exceed the allowable lateral movement value(15mm), and that the counterweight fill method was effective for the stability of the lateral movement.

Application of Bootstrap and Bayesian Methods for Estimating Confidence Intervals on Biological Reference Points in Fisheries Management (부트스트랩과 베이지안 방법으로 추정한 수산자원관리에서의 생물학적 기준점의 신뢰구간)

  • Jung, Suk-Geun;Choi, Il-Su;Chang, Dae-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.2
    • /
    • pp.107-112
    • /
    • 2008
  • To evaluate uncertainty and risk in biological reference points, we applied a bootstrapping method and a Bayesian procedure to estimate the related confidence intervals. Here we provide an example of the maximum sustainable yield (MSY) of turban shell, Batillus cornutus, estimated by the Schaefer and Fox models. Fitting the time series of catch and effort from 1968 to 2006 showed that the Fox model performs better than the Schaefer model. The estimated MSY and its bootstrap percentile confidence interval (CI) at ${\alpha}=0.05$ were 1,680 (1,420-1,950) tons for the Fox model and 2,170 (1,860-2,500) tons for the Schaefer model. The CIs estimated by the Bayesian approach gave similar ranges: 1,710 (1,450-2,000) tons for the Fox model and 2,230 (1,760-2,930) tons for the Schaefer model. Because uncertainty in effort and catch data is believed to be greater for earlier years, we evaluated the influence of sequentially excluding old data points by varying the first year of the time series from 1968 to 1992 to run 'backward' bootstrap resampling. The results showed that the means and upper 2.5% confidence limit (CL) of MSY varied greatly depending on the first year chosen whereas the lower 2.5% CL was robust against the arbitrary selection of data, especially for the Schaefer model. We demonstrated that the bootstrap and Bayesian approach could be useful in precautionary fisheries management, and we advise that the lower 2.5% CL derived by the Fox model is robust and a better biological reference point for the turban shells of Jeju Island.

Retrofitting of vulnerable RC structures by base isolation technique

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Ahmmad, Rasel;Darain, Kh. Mahfuz ud
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.603-623
    • /
    • 2015
  • The scale and nature of the recent earthquakes in the world and the related earthquake disaster index coerce the concerned community to become anxious about it. Therefore, it is crucial that seismic lateral load effect will be appropriately considered in structural design. Application of seismic isolation system stands as a consistent alternative against this hazard. The objective of the study is to evaluate the structural and economic feasibility of reinforced concrete (RC) buildings with base isolation located in medium risk seismic region. Linear and nonlinear dynamic analyses as well as linear static analysis under site-specific bi-directional seismic excitation have been carried out for both fixed based (FB) and base isolated (BI) buildings in the present study. The superstructure and base of buildings are modeled in a 3D finite element model by consistent mass approach having six degrees of freedom at each node. The floor slabs are simulated as rigid diaphragms. Lead rubber bearing (LRB) and High damping rubber bearing (HDRB) are used as isolation device. Change of structural behaviors and savings in construction costing are evaluated. The study shows that for low to medium rise buildings, isolators can reduce muscular amount of base shears, base moments and floor accelerations for building at soft to medium stiff soil. Allowable higher horizontal displacement induces structural flexibility. Though incorporating isolator increases the outlay, overall structural cost may be reduced. The application of base isolation system confirms a potential to be used as a viable solution in economic building design.

Edge Computing-based Differential Positioning Method for BeiDou Navigation Satellite System

  • Wang, Lina;Li, Linlin;Qiu, Rui
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.69-85
    • /
    • 2019
  • BeiDou navigation satellite system (BDS) is one of the four main types of global navigation satellite systems. The current system has been widely used by the military and by the aerospace, transportation, and marine fields, among others. However, challenges still remain in the BeiDou system, which requires rapid responses for delay-sensitive devices. A differential positioning algorithm called the data center-based differential positioning (DCDP) method is widely used to avoid the influence of errors. In this method, the positioning information of multiple base stations is uploaded to the data center, and the positioning errors are calculated uniformly by the data center based on the minimum variance or a weighted average algorithm. However, the DCDP method has high delay and overload risk. To solve these problems, this paper introduces edge computing to relieve pressure on the data center. Instead of transmitting the positioning information to the data center, a novel method called edge computing-based differential positioning (ECDP) chooses the nearest reference station to perform edge computing and transmits the difference value to the mobile receiver directly. Simulation results and experiments demonstrate that the performance of the ECDP outperforms that of the DCDP method. The delay of the ECDP method is about 500ms less than that of the DCDP method. Moreover, in the range of allowable burst error, the median of the positioning accuracy of the ECDP method is 0.7923m while that of the DCDP method is 0.8028m.

A Study on Microbial Contamination of Foods Exposed to Multiple Environments

  • KIM, Dan-Bee;CHA, Seong-Soo
    • The Korean Journal of Food & Health Convergence
    • /
    • v.5 no.3
    • /
    • pp.35-40
    • /
    • 2019
  • In this study, general bacterial counts and coliform counts, which are hygienic indicator microorganisms, were tested for candy, chocolate, and jelly which are easily available and enjoyed around. After dropping each sample on the desk, indoors, and outdoors, it is immediately collected, or washed and collected to confirm the myth of the 3-second rule. Immediately after removing the wrapping paper, each sample was dropped on the desk, indoors, and outdoors, and after 3 seconds from the moment of contact with the surface, and then collected in a sample bag using sterilized sanitary gloves. After the same operation, each sample was rinsed for 5 seconds using sterilized sanitary gloves and sterilized distilled water, and then collected in a sample bag. The number of bacteria detected in non-washing candies was 41 CFU/g at outdoor and the number of bacteria detected in non-washing chocolate was 76 CFU/g at outdoor. The number of bacteria detected in non-washing jellies was 79 CFU/g at outdoor. Coliform group was not detected in all samples. This showed good results at the level of m = 10,000 or less, which is an allowable value suggested in the Food Code. Also, effect of washing on contaminated food was confirmed. This result is remarkably low compared with the microorganism specimens shown in Food Code, and it is confirmed that contamination occurs but not high value. Therefore, the myth of the 3-second rule is true compared to the figures based on Food Code. However, it showed the characteristics of bacteria that could survive and cross-contaminate on dry food surfaces and emphasized the importance of hygiene through food contact to unsanitary surfaces to minimize the risk of food poisoning.

Small UAV Failure Rate Analysis Based on Human Damage on the Ground Considering Flight Over Populated Area (도심 지역 비행을 위한 지상 인명 피해 기반 소형무인기 고장 빈도 분석)

  • Kim, Youn-Sil;Bae, Joong-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.781-789
    • /
    • 2021
  • In this paper, we quantitatively analyzed the required UAV(Unmanned Aerial Vehicle) failure rate of small UAV (≤25kg) based on the harm to human caused by UAV crash to fly over the populated area. We compute the number of harm to human when UAV falls to the ground at certain descent point by using population density, car traffic, building to land ratio, number of floors of building data of urban area and UAV descent trajectory modeling. Based on this, the maximum allowable UAV failure rate is calculated to satisfy the Target Level of Safety(TLS) for each UAV descent point. Then we can generate the failure rate requirement in the form of map. Finally, we divide UAV failure rate into few categories and analyze the possible flight area for each failure rate categories. Considering the Youngwol area, it is analyzed that the UAV failure rate of at least 10-4 (failure/flight hour) is required to access the residential area.

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

A Study on the Fire Risk of High-voltage Cables for Electrical Vehicles (전기차용 고전압 케이블의 화재 위험성에 관한 연구)

  • Sin Dong Kang;Ye Jin Park;Si Hyun Kim;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.8-14
    • /
    • 2023
  • This study presents the characteristics of short circuits (SCs) caused by excessive currents in high-voltage cables used in electric vehicles and emphasizes the need to calculate the cross-sectional areas of these cables according to the SC current. Three direct current power supplies were connected in parallel to test the SC characteristics caused by excessive currents, and a timer and a magnetic contactor were used to deliver the conduction time and SC current. A circular infrared-radiation heater was used to test the temperature-dependent SC characteristics, a thermocouple was used to measure the temperature, and a shunt resistor was used to measure the current. As the SC current increased, the fusing time of the cable decreased. Additionally, a high-voltage cable (with an area of 16 mm2 ) used in electric vehicles fused when a current (approximately equal to 55 times the allowable current) flowed for 0.2 s (operating time of the protective device). When the SC current is 10 kA, the cable may fuse during the operating time of the protective device, thus creating a fire hazard. In electric vehicles, the size of the SC current increases in proportion to the capacity of the battery. Thus, the cross-sectional areas of the cables used should be calculated accordingly, and cable operations should be properly coordinated with the surrounding protective devices.