• 제목/요약/키워드: Allied health science

검색결과 148건 처리시간 0.019초

흉부 X선사진 시스템의 성능평가 (The Evaluation of Chest Radiographic Systems)

  • 강해원;박준철;강홍석;이인자;신화수;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.31-35
    • /
    • 1987
  • Authors have investigated actual conditions of 22 hospitals throughout the Seoul district to evaluate of chest radiographic systems. The results are as followed: 1. Concerning exposure factors, most hospitals have used low tube voltage, merely two hospitals high tube voltage, that is, over 120 kVp. Roughly halves of intensifying screens have been used in hospitals were medium speed screens, and the rests were high speed screens. 2, Surface doses existed within wide range of $10{\sim}63.5mR$, and image quality value were $5.60{\sim}7.49$. 3. The minimum perceptibility of Burger Phantom have been increased with contrast improvement.

  • PDF

Comparative Characterization of Four Calcium-Binding EF Hand Proteins from Opisthorchis viverrini

  • Emmanoch, Palida;Kosa, Nanthawat;Vichasri-Grams, Suksiri;Tesana, Smarn;Grams, Rudi;Geadkaew-Krenc, Amornrat
    • Parasites, Hosts and Diseases
    • /
    • 제56권1호
    • /
    • pp.81-86
    • /
    • 2018
  • Four isoforms of calcium binding proteins containing 2 EF hand motifs and a dynein light chain-like domain in the human liver fluke Opisthorchis viverrini, namely OvCaBP1, 2, 3, and 4, were characterized. They had molecular weights of 22.7, 21.6, 23.7, and 22.5 kDa, respectively and showed 37.2-42.1% sequence identity to CaBP22.8 of O. viverrini. All were detected in 2- and 4-week-old immature and mature parasites. Additionally, OvCaBP4 was found in newly excysted juveniles. Polyclonal antibodies against each isoform were generated to detect the native proteins in parasite extracts by Western blot analysis. All OvCaBPs were detected in soluble and insoluble crude worm extracts and in the excretory-secretory product, at approximate sizes of 21-23 kDa. The ion-binding properties of the proteins were analyzed by mobility shift assays with the divalent cations $Ca^{2+}$, $Mg^{2+}$, $Zn^{2+}$, and $Cu^{2+}$. All OvCaBPs showed mobility shifts with $Ca^{2+}$ and $Zn^{2+}$. OvCaBP1 showed also positive results with $Mg^{2+}$ and $Cu^{2+}$. As tegumental proteins, OvCaBP1, 2, and 3 are interesting drug targets for the treatment of opisthorchiasis.

Determining Potential Link between Environmental and Clinical Isolates of Cryptococcus neoformans/Cryptococcus gattii Species Complexes Using Phenotypic and Genotypic Characterisation

  • Kenosi Kebabonye;Mosimanegape Jongman;Daniel Loeto;Sikhulile Moyo;Wonderful Choga;Ishmael Kasvosve
    • Mycobiology
    • /
    • 제51권6호
    • /
    • pp.452-462
    • /
    • 2023
  • Opportunistic infections due to Cryptococcus neoformans and C. gattii species complexes continue to rise unabated among HIV/AIDS patients, despite improved antifungal therapies. Here, we collected a total of 20 environmental and 25 presumptive clinical cryptococcal isolates from cerebrospinal fluid (CSF) samples of 175 patients enrolled in an ongoing clinical trial Ambition 1 Project (Botswana-Harvard Partnership). Identity confirmation of the isolates was done using MALDI-TOF MS and PCR. We describe the diversity of the isolates by PCR fingerprinting and sequencing (Oxford Nanopore Technology) of the intergenic spacer region. Mating types of the isolates were determined by amplification of the MAT locus. We report an unusual prevalence of 42.1% of C. neoformans × C. deneoformans hybrids Serotype AD (n = 16), followed by 39.5% of C. neoformans Serotype A (n = 15), 5.3% of C. deneoformans, Serotype D (n = 2), 7.9% of C. gattii (n = 3), and 5.3% of C. tetragattii (n = 2) in 38 representative isolates that have been characterized. Mating type-specific PCR performed on 38 representative environmental and clinical isolates revealed that 16 (42.1%) were MATa/MAT𝛼 hybrids, 17 (44.7%) were MAT𝛼, and five (13.2%) possessed MATa mating type. We used conventional and NGS platforms to demonstrate a potential link between environmental and clinical isolates and lay a foundation to further describe mating patterns/history in Botswana.

희토류 증감지를 이용한 여과판의 효과 (A Study on the Effect of Rare Earth Screen Filter)

  • 허준;김창균;이인자;신화수;박준철;강홍석;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권1호
    • /
    • pp.17-23
    • /
    • 1988
  • As the reutilizing method of exhausted screen, authors used it as a filter and compared with the aluminium filtration. The results are as followed; 1. One sheet of gadolinium front screen has the same radiation absorption as $2.8{\sim}3.3\;mm$ Al equivalent and regular tungsten screen $2.3{\sim}2.7mm$ Al. 2. HVL after Gd-screen filtration was less than the values after aluminium and tungsten-screen filtration. And, image definition with Gd-screen filtration was better than other two cases. Ana surface dose to produce a same film density was more than other two cases. It will be very useful to apply, Gd-screen filter in clinics as it has no deficiency of image quality.

  • PDF

편면 증감지 -필름계의 성능실험 (An Experiment on Single Screen-Film System)

  • 강홍석;박준철;신화수;이인자;허준;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.55-59
    • /
    • 1987
  • Single screen-film systems have been used to soft tissue radiography, especially to mammo-graphy, for the Purpose of reducing patient dose, Recently, by the development of rare earth screens, they are being used to general radiography including stomach radiography. Single screen-film systems have lower speeds, but higher resolutions than double screen-film systems. And so, they can produce high image quality in oblique radiography and tomography. Authors have tested basic and physical characteristics of sigle screen-film systems, and applied them in clinical fields. Hereupon, we evaluate the sin91e rare earth screen-film systems very practicable, because they have higher speeds and higher image quality than double screen-film systems.

  • PDF

Correlation Between Functional Movement Screen Scores, Lower Limb Strength, Y-Balance Test, Grip Strength, and Vertical Jump and Incidence of Injury Due to Musculoskeletal Injury Among Abu Dhabi Police Recruits

  • Hamad Alkaabi;Everett Lohman;Mansoor Alameri;Noha Daher;Aleksandar Cvorovic;Hatem Jaber
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권3호
    • /
    • pp.222-228
    • /
    • 2023
  • Objective: Training-related injuries and attrition put an additional burden on police and military institutions. Preventing and minimizing musculoskeletal injuries is the primary concern of the Abu Dhabi Police. Therefore, this study aimed to evaluate the correlation between functional movement screen, lower-limb strength, Y-balance test, grip strength and vertical jump and the incidence of musculoskeletal injuries among Abu Dhabi police recruits. Design: Observational analytical study. Methods: An observational study was conducted on 400 male police recruits of Abu Dhabi Police Academy. Physical performance was assessed before the 16-weeks basic police training. Spearman's correlation evaluated the correlation between the performance parameters and the outcome measures and logistic regression predicted the risk factors associated with musculoskeletal injuries. Results: 149 (34.4%) participants reported at least one injury during the basic police training. Comparison between injured and non-injured participants showed significant difference in mean right Y-balance, back-leg-chest dynamometer, and vertical jump (p=0.02, p=0.02, and p=0.04, respectively). Spearman's correlation showed a significant negative correlation between risk of injury and back-leg-chest dynamometer and right Y balance (ρ= -0.11, p=0.03). Logistic regression showed that back-leg-chest dynamometer and right Y balance were significant predictors of injury (p =.036 and p=0.037; Odds ratio=0.96; 95% CI (0.92, 0.99) and Odds ratio=0.99; 95% CI (0.98,0.99). Conclusions: Our findings suggest functional movement screen and grip strength may not independently predict injury rates, balance and lower-limb strength needs to be considered in injury prevention strategies to reduce musculoskeletal injuries.

Inverter 방식(方式) X선장치(X線裝置)의 임상응용(臨床應用) (Clinical Application of Inverter type X-ray Generator)

  • 이선숙;허준;이재원;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.107-113
    • /
    • 1992
  • Inverter type X-ray apparatus has been introduced and used several hospitals. Principle of inverter type X-ray generators are such as to convert the frequency of commercial power supply to high frequency and to control the high voltages for X-ray tube. Inverter generators are now on the way for futher development to elliminate single phase generators and three phase generators. We compared inverter type X-ray apparatus with conventional single phase 2 peak and three phase 12 peak, apparatus in the following aspects X-ray out put to tube voltage, linearity of X-ray out put to mA, HVL according to mA contrast to kV.

  • PDF