• Title/Summary/Keyword: All-Pass Filter (APF)

Search Result 15, Processing Time 0.024 seconds

Novel Fast Peak Detector for Single- or Three-phase Unsymmetrical Voltage Sags

  • Lee, Sang-Hoey;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.658-665
    • /
    • 2011
  • In the present paper, a novel fast peak detector for single- or three-phase unsymmetrical voltage sags is proposed. The proposed detector is modified from a single-phase digital phase-locked loop based on a d-q transformation using an all-pass filter (APF). APF generates a virtual phase with $90^{\circ}$ phase delay. However, this virtual phase cannot reflect a sudden change of the grid voltage in the moment of voltage sag, which causes a peak value to be significantly distorted and to settle down slowly. Specifically, the settling time of the peak value is too long when voltage sag occurs around a zero crossing, such as phase $0^{\circ}$ and $180^{\circ}$. This paper describes the operating principle of the APF problem and proposes a modified all-pass filter (MAPF) to mitigate the inherent APF problem. In addition, a new fast peak detector using MAPF is proposed. The proposed detector is able to calculate a peak value within 0.5 ms, even when voltage sag occurs around zero crossing. The proposed fast peak detector is compared with the conventional detector using APF. Results show that the proposed detector has faster detection time in the whole phase range. Furthermore, the proposed fast peak detector can be effectively applied to unsymmetrical three-phase voltage sags. Simulation and experimental results verify the advantages of the proposed detector and MAPF.

Instantaneous reactive power and active power measurement techniques using All Pass Filter (All Pass Filter를 이용한 순시 무효전력, 유효전력 측정기법)

  • Jeong, D.W.;Kim, S.P.;Hwang, J.G.;Park, S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.447-448
    • /
    • 2015
  • 지연 등화기(Delay Equalizer) 또는 위상 필터(Phase Filter)라고도 불리는 전역 통과 필터(All Pass Filter)는 주파수의 변화와 관계없이 위상만을 변화 시키는 시간 지연 장치(Time Delay Device)이다. 모든 주파수에서 진폭의 이득이 '0' 또는 일정하지만, 위상의 특성만을 개선하기 위해 사용되는 위상 필터 이다. 본 논문은 이와 같은 전역 통과 필터(APF)의 특성을 이용하여 순시 유효 전력(Active Power) 및 순시 무효 전력(Reactive Power)의 측정 방법에 대하여 연구하였다. 전역 통과 필터(APF)의 좌표변환을 사용하여, 필터에서의 정보를 통한 유효 전력과 무효 전력 측정이 가능하다. 따라서 본 논문에서는 시뮬레이션을 통해 그 타당성을 검증하였다.

  • PDF

The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage (이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.

PLL for Unbalanced Three-Phase Utility Voltage using Positive Sequence Voltage Observer (정상분 전압 관측기를 이용한 불평형 3상 전원의 PLL)

  • Kim, Hyeong-Su;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.145-151
    • /
    • 2008
  • This paper proposes the PLL method using positive sequence voltage which is estimated by full-order state observer to find an accurate phase angle under the condition of unbalanced utility voltage. The proposed method uses the full-order state observer instead of existing method(APF All Pass Filter) to find a positive sequence of a utility voltage and this proposed method improves transient response of an estimated phase angle when a three-phase utility voltage becomes unbalanced. To compare proposed method withexisting method, experiments have been done for a phase angle detection of utility voltage when a three-phase utility voltage becomes unbalanced. Their results show that transient state response of proposed method is improved.

Analysis and Design Algorithm of Time Varying Reverberator for Low Memory Applications (저전력 환경에 적합한 시간변화 잔향기의 분석 및 설계 알고리듬)

  • Choi Tack-Sung;Park Young-Cheol;Youn Dae-Hee
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.5 s.311
    • /
    • pp.62-71
    • /
    • 2006
  • Development of an artificial reverberation algorithm with low memory requirements has been an issue of importance in applications such as mobile multimedia devices. One possible solution to this problem is to embed a time-varying all-pass filter to the feedback loop of the comb filter. In this paper, theoretical and perceptual analyses of reverberators embedding time-varying all-pass filters are presented. The analyses are to iud a perceptually acceptable degree of phase variation by the all-pass filter. Based on the analyses, we propose a new methodology of designing reverberators embedding time-varying all-pass filters. Through the subjective tests, we showed that, even with smaller memory, the proposed method is capable of providing perceptually comparable sound quality to the conventional methods involving time-invariant parameters.

Time-Domain Numerical Investigation of Ring Resonator Optical Delay Devices

  • Chung, Youngchul
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.441-446
    • /
    • 2013
  • A split-step time-domain model for the analysis of pulse delay characteristics through ring resonator all-pass filters (APF's) is developed and its accuracy is checked. The dependence of the delay time and pulse distortion on the coupling ratios is investigated using the model. It is observed that the bandwidth of the APF's needs to be wide enough to minimize the pulse distortion.

Fast Detection Algorithm for Voltage Sags and Swells Based on Delta Square Operation for a Single-Phase Inverter System

  • Lee, Woo-Cheol;Sung, Kook-Nam;Lee, Taeck-Kie
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.157-166
    • /
    • 2016
  • In this paper, a new sag and peak voltage detector is proposed for a single-phase inverter using delta square operation. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on d-q transformations using an all-pass filter (APF). The d-q transformation is typically used in the three-phase coordinate system. The APF generates a virtual q-axis voltage component with a 90° phase delay, but this virtual phase cannot reflect a sudden change in the grid voltage at the instant the voltage sag occurs. As a result, the peak value is drastically distorted, and it settles down slowly. A modified APF generates the virtual q-axis voltage component from the difference between the current and the previous values of the d-axis voltage component in the stationary reference frame. However, the modified APF cannot detect the voltage sag and peak value when the sag occurs around the zero crossing points such as 0° and 180°, because the difference voltage is not sufficient to detect the voltage sag. The proposed algorithm detects the sag voltage through all regions including the zero crossing voltage. Moreover, the exact voltage drop can be acquired by calculating the q-axis component that is proportional to the d-axis component. To verify the feasibility of the proposed system, the conventional and proposed methods are compared using simulations and experimental results.

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

Converter Control for APU of 8200 Series Electric Locomotive using Advanced Single Phase PLL Control Method (진보된 단상 PLL 제어방법을 이용한 8200호대 전기기관차 보조전원장치용 컨버터 제어)

  • Jung, No-Geon;Lee, Eul-Jae;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.211-215
    • /
    • 2017
  • The APF (All Pass Filter) method that utilizes the computational power of the controller is most commonly used. However, since the calculation of the filter coefficient is complicated, the calculation is carried out in advance. It is difficult to apply it to the frequency fluctuation environment because the coefficient value is fixed. In this paper, a new control method of single phase PLL that can be usefully used in PWM converter device for electric railway was explained. Comparison and examination of similarities and differences between the conventional APF method PLL controller method and the newly proposed modified MA filter method PLL technique were performed. The possibility of implementation of the modified MA filter method through computer simulation was analyzed. In conclusion, the method proposed as the conclusion was applied to the APU(Auxiliary Power System) of 8200 Series Electric Locomotive and its usefulness was confirmed.

A Novel Active Damping Control of a Three-phase PWM Inverter with LC Filter

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1589-1596
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of 2nd order low pass filter(2nd LPF) which has a zero damping ratio. A simple method of implementing 2nd LPF with damping ratio is to add resistor to inductor or capacitor of LC filter. In an industrial application, it is not practical to adopt damping resistor because it results in losses being proportional to square of current flowing through resistor. Instead of using damping resistors, the proposed active damping control(ADC) utilizes all pass filter(APF) and considers inherent processing delay of digital controller. The overall transfer function of the proposed method is the same as a 2nd LPF and its damping ratio is also controllable via control variables. Detailed design and implementation of controller is also presented. Experiments are conducted with a 7.5kVA induction motor drive system controlled by PWM converter and inverter. Test waveforms are also presented to verify the proposed LC filter control algorithm.