• Title/Summary/Keyword: All in One PC

Search Result 262, Processing Time 0.027 seconds

Design Alteration of a All in One PC for the Improved Stability (일체형 컴퓨터의 구조 안정화를 위한 설계 개선)

  • Kim, Dong Wook;Ro, Seung Hoon;Kim, Geon Hyeong;Yang, Yong Jun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.6
    • /
    • pp.109-116
    • /
    • 2013
  • Vibrations are generally recognized as the biggest concern in maintaining part' longevity of an All-in-one PC. The vibrations in PCs originate from excitation sources such as the HDD and the cooling fan. In this study, the vibrations from these sources were investigated in order to analyze the individual effects of the parameters on the structural vibrations of the PC; further, we attempted to establish design alterations that could successfully suppress vibrations, in order to achieve improved stability and part' longevity. The results show that relatively simple design alterations can substantially improve the stability of PCs.

Binding energy study from Photocurrent signal in $CdGa_2Se4$ layers

  • Lee, Sang-Youl;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.47-47
    • /
    • 2009
  • The photoconductive $CdGa_2Se4$ layer has been investigated using photocurrent (PC) spectroscopy as a function of temperature. Three peaks corresponding to the band-to-band transitions were observed in the PC spectra for all temperature ranges. Also, contrary to our expectation, the PC intensities decreased with decreasing temperatures. From the relation of log $J_{ph}$ vs 1/T, where $J_{ph}$ is the PC density, two dominant levels by the exponential variation of the PC with varying temperature were observed, one at high temperatures and the other at low temperatures.

  • PDF

The Genetic Diversity of Trans-caucasian Native Sheep Breeds

  • Hirbo, Jibril;Muigai, Anne;Naqvi, A.N.;Rege, E.D.;Hanotte, Olivier
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.7
    • /
    • pp.943-952
    • /
    • 2006
  • The genetic variation in 10 indigenous Caucasian sheep breeds was studied with 14 micro-satellite loci in order to determine the genetic diversity among and between the breeds. Five breeds from Asia, five breeds from Europe and one breed from Africa, were included in order to study any relationships or influences they may have with the Caucasian sheep analyzed. A Karakul population from Uzbekistan was included in the study to see whether there was any Central Asian influence. All the 14 loci were found to be polymorphic in all the breeds, with the exception of ILST0056, which was monomorphic in Imeretian. A total of 231 alleles were generated from all the 688 individuals of the sheep analyzed. The mean number of alleles (MNA) at each locus was 16.5. The total number of alleles detected in all samples ranged from 13 in several loci to 23 in OarJMP029. Out of total 308 Hardy-Weinberg Equilibrium (HWE) tests, 85 gave significant results. After Bonferroni correction for multiple tests, 30 comparisons still remained significant to the experimental levels. The Gala population was the most diverse and Imeretian the least diverse with a MNA of 8.50 and 5.51, respectively. Gene diversity estimates exhibited the same trend and ranged from 0.803 in Gala and 0.623 in Imeretian, but generally there is higher diversity among the Caucasian breeds in comparison to other eference breeds. The closest breeds were Tushin and Bozakh with Da of 0.113 and most distant breeds were $Djallonk{\acute{e}}$ and North Rondalsy with Da of 0.445. Principal Component (PC) analyses were done. PC1 described 14% of the differences. PC2, which described 13% of the differences, further separated the Caucasian breeds from Asian breeds except Karakul and Awasi, and the two British breeds. PC3 described 10% of the differences, allowing better differentiation of the Caucasian breeds. A moderate degree of reliability was observed for individual-breed assignment from the 14 loci using different approaches among which the Bayesian method proved to be the most efficient. About 72% of individuals analyzed were correctly assigned to their respective breeds.

Effects of Dietary Supplementation with Galla Rhois on Growth Performance and Diarrhea Incidence in Postweaning Piglets (이유자돈에 있어서 성장증체 및 설사발생에 미치는 오배자의 급여 효과)

  • Cha, Chun-Nam;Yu, Eun-Ah;Park, Eun-Kee;Kim, Suk;Lee, Hu-Jang
    • Journal of Veterinary Clinics
    • /
    • v.30 no.5
    • /
    • pp.353-358
    • /
    • 2013
  • A study investigated the effects of Galla Rhois (GR) on growth performance and diarrhea incidence of postweaning piglets. One hundred 28-day-old piglets were randomly assigned into five experimental groups, which were a basal diet alone (NC), chlortetracycline 0.3 g/kg feed (PC) and supplemented with GR 1.0 g/kg feed (GR 1), GR 2.0 g/kg feed (GR 2), and GR 4.0 g/kg feed (GR 3). After 28 days of administration, final body weight (BW) and feed conversion ratio of PC, GR 2 and GR 3 was significantly different compared to those of NC (p < 0.05). Additionally, the average daily gain (ADG) and average daily feed intake (ADFI) of PC and all groups treated with GR was significantly different compared to those of NC (p < 0.05). Especially, final BW, ADG, ADFI and feed conversion ratio (FCR) of GR 2 and GR 3 were not significant different compared to those of PC. In fecal scores and duration of diarrhea, PC and all groups treated with GR were significantly different compared to NC (p < 0.05). In hematogolical and serum biochemical analysis, there were no significant differences in any of the hematogolical and serum biochemical parameters examined in either NC or all groups treated with GR. The results of this study indicated that GR could be a potential candidate as feed additives for the improvement of growth performance and incidence of diarrhea in piglets.

Influence of Fatigability on the Timing of Reassessment in the Treatment of Posterior Canal Benign Paroxysmal Positional Vertigo (후반고리관 양성돌발두위현훈의 치료에서 재평가 시기에 대한 피로 현상의 영향)

  • Kim, Chang-Hee;Shin, Jung Eun;Shin, Yong Gook;Song, Mee Hyun;Shim, Dae Bo
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.658-662
    • /
    • 2018
  • Background and Objectives The early assessment of treatment is not done for benign paroxysmal positional vertigo (BPPV) since the well-known phenomenon of fatigability after a repeated positional test can mimic successful treatment. The aim of this study is to evaluate the clinical implication of 'fatigability' after Epley maneuver and to identify the therapeutic efficacy of Epley maneuver in posterior canal BPPV (PC-BPPV). Subjects and Method This study was prospectively conducted by two dizziness clinics on 51 consecutive patients diagnosed with PC-BPPV. All patients included in the study received Epley maneuver treatment. The therapeutic results were reassessed immediately after a single trial of Epley maneuver. After 30 minutes, results were reassessed repeatedly to confirm the fatigability of diagnostic procedure immediately after treatment. If the treatment was not successful after 30 minutes, Epley maneuver was repeatedly performed until complete resolution. Results Immediately after the first maneuver, 45 of 51 (88.2%) patients had neither vertigo nor nystagmus during the positional test. All patients demonstrated complete resolution after receiving one to three Epley maneuvers on the day of diagnosis. 'Fatigability (false negative result)' was confirmed for only one case (1 of 6 patients, 16.7%), in which nystagmus was observed after 30 minutes but not identified immediately after the first Epley maneuver. Conclusion The therapeutic efficacy of Epley maneuver is very high in PC-BPPV. Considering the possibility of fatigability when reassessment is performed immediately after therapeutic maneuver, clinicians should avoid assessing the outcome immediately after treatment in patients with PC-BPPV.

Phenolic Compounds from Antioxidant Plant Materials and their Protective Effect on PC12 cells (항산화 식물의 페놀성화합물에 의한 PC12 세포보호 효과연구)

  • You, SoHyeon;Kim, Gun-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.33 no.1
    • /
    • pp.86-94
    • /
    • 2018
  • This study was designed to evaluate the antioxidant activities and protective effects on PC12 cells of the extract of Epimedium koreanum and its main constituents icariin and icariside I. After screening the seven identified flavonoid glycosides from E. koreanum through DPPH (2,2-diphenyl-1-picryl-hydrazyl-hydrate) assay, E. koreanum, Icariin and Icariside I exhibited significant effect on radical scavenging activity. E. koreanum, icariin and icariside I were examined using DPPH, ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid)) and FRAP (ferric reducing ability power) assay. In all antioxidant assays, E. koreanum, icariin and icariside I showed high radical scavenging activities in a dose-dependent manner. Protective effects against $H_2O_2-induced$ PC12 cells were assessed with MTT assay. The results indicated that cell viability and protection on PC12 cells of icariside I and icariin increased dose dependently. These study results suggest that E. koreanum, icariin and icariside showed high antioxidant capacities and cell protective effects. Icariside I, one of the metabolites of icariin, may be a new and effective flavonoid compound as a functional component.

Size and Crystal Structure Dependence of Photochromism of Nanocrystalline WO3 and MoO3 Prepared by Acid-Precipitation Method

  • Jun Young, Kwak;Young Hee, Jung;Yeong Il, Kim
    • Journal of the Korean Chemical Society
    • /
    • v.67 no.1
    • /
    • pp.33-41
    • /
    • 2023
  • Nanocrystallne WO3 and MoO3 with several different sizes and crystal structures were prepared by simple acid precipitation and subsequent heat treatment. The photochromic (PC) properties of these samples were comparatively investigated in powder state by monitoring diffuse reflectance spectral changes after bandgap irradiation. The PC effect of hexagonal WO3 and monoclinic WO3 strongly depended upon crystallite size rather than crystal structure. The smaller the crystallite size, the better the PC effect. However, orthorhombic WO·H2O and MoO3 having hexagonal and orthorhombic structures did not follow this trend. One consistent result for all WO3 and MoO3 samples is that the heat treatment in air, which changes crystallinity, whether it changes the crystal structure or only the crystallite size, reduces the PC effect. Since the thermal treatment reduces the surface oxygen defect sites, we believe that the PC effect of WO3 and MoO3 depends critically on the surface oxygen defect sites that serve as deep trap sites for photogenerated electrons and oxygen radical holes. We also found that the proton insertion claimed by double charge injection model is not critical for the PC effect.

Acupuncture on PC6 in Anesthesia also Shows Effect for Preventing Post Operative Nausea and Vomiting (마취 중 내관 침 시술이 수술 후 오심구토 예방에 미치는 효과)

  • Choi, Deok-Hwa;Lee, Su-Kyung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.6
    • /
    • pp.1085-1088
    • /
    • 2011
  • This study aims to investigate the effect of acupuncture on PC6 for preventing opioid-induced nausea and vomiting under circumstance whether the participants are conscious or non-conscious. 143 patients receiving intravenous patient controlled analgesia(PCA) with fentanyl were assigned to three groups. Two groups were given acupuncture on PC6 before anesthesia(PreAN) or after anesthesia(PoAN) respectively. One group was control group without acupuncture treatment(NC). Assessment of nausea and vomiting was obtained from all patients for 48hours after surgery. The incidence of nausea and vomiting was significantly lower in the PreAN group and PoAN group than in the NC group. The severity of nausea was the lowest in PreAN group, second to in PoAN group, and the highest in NC group. This results show that acupuncture on PC6 even without patients' consciousness has effect on preventing PONV.

Time-Dependent Degradation Model and Maintenance Cost of Rail line PC Beam Bridge in Project Level (Project level에서의 철도 PC Beam교량의 경년열화모델구성 및 유지관리비용 추정)

  • Kwon, Se-Gon;Park, Mi-Yun;Do, Jeong-Yun;Kim, Do-Kie
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.17-22
    • /
    • 2008
  • Construction project have extremely high risk in the process of construction owing to unexpected event, like as design amendment. As a result, owner have to endure enormous extra-cost to control the risk and continue to the project having more higher uncertainty. Also, if the structure is completed, it is needed that the structure is protected and maintained continuously during life cycle time to satisfying original aim of structure itself. LCC analysis to calculate cost of structure alternatives divides into two stage, one is design_LCC and the other is maintenace_LCC. But two stages all is needed in the transition deterioration model to calculate more reasonable LCC analysis. This paper developed the model using analysis of FMS contents and survey from professional about Prestressed concrete beam girder bridge(PC Beam bridge)in railway. The model is focused in project level of PC beam because any condition state information for element level analysis can not get up. This paper is intended to use the developed model in LCC analysis of PC Beam bridge in railway and constitute the foundation to perform more deep study in the near future.

  • PDF

Realtime Wireless Monitoring of Abnormal ST in ECG Using PC Based System

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun;Inooka, Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.176-180
    • /
    • 2004
  • The ST-segment that the beginning part of T wave is the important diagnostic parameter to finding myocardial ischemia. Abnormal ST appears in two types. One is the level change, and the other is the pattern change. In this paper, we describe the monitoring of abnormal ST using PC based system. Hardware of this system consists of transmitter, receiver and PC. The function of transmitter is measuring ECG in three channels which are selected manually and transmitting the data to receiver by digital radio way. Connection with receiver and PC is by RS232C, and the data received on the PC is analyzed automatically by ECG analysis algorithm and saved to file. In the algorithm part for detecting abnormal ST, ST-segments are approximated by a polynomial. This method can detect all of the deviation and pattern change of ST-segment regardless the change in the heart rate or sampling rate. To gain algorithm reliability, the method rejects distorted polynomial approximation by calculation the difference between the approximated ST-segment and original ST-segment. In pre-signal processing, the wavelet transformation separates high frequency bands including QRS complex from the original ECG. Consequently, the process improves the performance of detecting each feature points.

  • PDF