• Title/Summary/Keyword: All Air

Search Result 3,835, Processing Time 0.03 seconds

A study on the Application of STS wire Mesh air Cleaner for the 2-Wheel Automotive (2륜 자동차 공기청정기의 STS적용에 관한 연구)

  • Yi, C.S.;Lee, Y.H.;Suh, J.S.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.30-35
    • /
    • 2002
  • This study represents the effects of the material of the air cleaner on the performance in a 4-stroke spark-ignition engine for motorcycles. This study is mainly focused on the possibility of the adopting the STS wire mesh air cleaner of a S.I engine. For investigating the possibility of that, the engine power, the fuel consumption and the exhaust gas analysis were carried out for the synthetic fiber air cleaner and the different size of 200 mesh, 250 mesh, 300 mesh of STS wire mash air cleaner. As the results of this study, the performance of STS wire air cleaner was similar to the fiber air cleaner at 9000 rpm but 300 mesh of STS air cleaner had a high engine power and torque at 9500 rpm. In the case of the synthetic fiber air cleaner the concentration of CO was low at 6500 rpm and in the case of the 300 mesh in STS wire mesh air cleaner the concentration of HC was lowest at all experimental regions.

  • PDF

Improvement of PM10 Forecasting Performance using DNN and Secondary Data (DNN과 2차 데이터를 이용한 PM10 예보 성능 개선)

  • Yu, SukHyun;Jeon, YoungTae
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.10
    • /
    • pp.1187-1198
    • /
    • 2019
  • In this study, we propose a new $PM_{10}$ forecasting model for Seoul region using DNN(Deep Neural Network) and secondary data. The previous numerical and Julian forecast model have been developed using primary data such as weather and air quality measurements. These models give excellent results for accuracy and false alarms, but POD is not good for the daily life usage. To solve this problem, we develop four secondary factors composed with primary data, which reflect the correlations between primary factors and high $PM_{10}$ concentrations. The proposed 4 models are A(Anomaly), BT(Back trajectory), CB(Contribution), CS(Cosine similarity), and ALL(model using all 4 secondary data). Among them, model ALL shows the best performance in all indicators, especially the PODs are improved.

Development of Self-propelled Explosive Subsoiler (2) - Construction of Prototype and Performance Evaluation - (자주식 심토환경 개선기 개발(2) - 본체 제작 및 성능 평가 -)

  • Lee, Dong-Hoon;Park, Woo-Pung;Kim, Sang-Cheol;Lee, Kyou-Seung
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.404-410
    • /
    • 2009
  • This study was carried out to develop a self-propelled type explosive subsoiler for improving the root zone soil conditions in orchard and other forest fields. Prototype was designed to be able to inject air and other soil improving material such as lime into soil at the same time, and thus improve the air permeability and drainage of orchard soils to promote the root growth of tree for high quality fruit production. Soil penetration device of explosive subsoiler is composed of air hammer, penetration rob and air injection nozzle. To support the soil penetration device of explosive subsoiler to penetrate vertically, modified Scott-Russel mechanism was used. Timing control device for simultaneous injection of soil improving material with air was attached to the out side wall of air cylinder and as the cylinder move, the soil improving material was injected into soil at the same time. Turning radius of prototype was 2.2-2.3 m with good mobility in sloped land. It took approximately 1 minute for lime injection system to reach the optimum pressure of 9.9 kg/$cm^2$, average 10-20 seconds were required to rupture soil with the depth of 50 cm and 2-3 seconds were required for explosion, so all in all about 1 minute and 20 seconds were required for one cycle of explosion. Maximum soil rupture depth and diameter were 50 cm and 3-4 m respectively depending on the soil type and soil moisture content. For final design of explosive subsoiler inclination angle of lime hopper was increased from 60 degree to 70 degree and the shape of hopper was changed from rectangular cone to circular cone to solve the clogging problem of lime at out let. Agitating system operated by compressed air was attached to the metering device of the prototype, thus more than 90 cc of lime was discharged per cycle from metering device without clogging problems.

Review of Association between Air Pollution and Heart Rate Variability (HRV) (대기오염과 심박변이도(Heart Rate Variability, HRV)의 연관성에 대한 고찰)

  • Guak, Sooyoung;Lim, Chaeyun;Lee, Kiyoung;Park, Ji Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.223-230
    • /
    • 2015
  • Objectives: There is considerable evidence that polluted ambient air contributes to the risk of cardiovascular morbidity and mortality. Heart rate variability (HRV) is defined as the variation in heartbeat intervals and has been reported as a biological marker of cardiovascular disease. This article reviews the existing literature in order to examine the association between air pollution and HRV. Methods: Literature was searched using Web of Science with the key words of "air pollution", "heart rate variability" and other related terms. A total of 156 articles were listed. For review, 21 of those listed publications were chosen after excluding studies regarding chamber studies, occupational environment, secondhand smoke and automobile exhaust. Results: Research methods employed in the publications were classified by type of participants (elderly/adult), air pollution monitoring (ambient/personal) and HRV monitoring (continuous/spot). Among HRV parameters, power in the low frequency range (LF), power in the high frequency range (HF) and standard deviation of all NN intervals (SDNN) were all associated with air pollutants. The chosen studies were mostly based on elderly populations. In studies based on continuous HRV monitoring, LF and SDNN significantly decreased when $PM_{2.5}$ exposure increased. Conclusion: Continuous HRV monitoring combined with personal exposure monitoring has been one of the most common study methods in recent publications. We expect that this review will be useful for the study of the association between air pollution and cardiovascular effects using HRV.

A Study on the Development of the Air Pollution-Health Risk Model : The case of Seoul, Korea. (都市大氣汚染이 市民健康에 미치는 危險性 評價 模型의 開發에 관한 硏究)

  • 김귀곤;김명진;성현찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.30-35
    • /
    • 1989
  • To effectively develop and evaluate air pollution control measures, health risk rates due to air pollution must be identified. This article describes the application of a visual analysis and an air pollution-health risk model for determining the impacts of carbon monoxide (CO) exposure on angina pectoris patients in a metropolitan area. The procedures used for analyzing the relationship between CO exposure and the related increase in angina angina attacks for stable angina pectoris patients are described through a case study in the city of Seoul, Korea and the findings show that air-pollution-health risk model and visual analysis can be effective tools for environmental decision-makers, allowing air pollution control scenarios to be developed and evaluated for environmental protection. One of the features of this study is to provide a methodology for translating clinical findings into estimates of the relative contributions of air pollution to all causes of a particular disease. Therefore, there must be appropriate recognition of the uncertainties involved in the study.

  • PDF

Calculation Method for the Concentration of Persistent Organic Pollutants (POPs) Collected by Passive Air Samplers (수동대기채취기를 이용한 잔류성유기오염물질의 농도산정)

  • Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.217-227
    • /
    • 2013
  • Passive air samplers (PAS) have been developed since the early 2000s and widely used for the atmospheric monitoring of persistent organic pollutants (POPs). PAS are useful especially for the investigation of source-receptor relationship of POPs because they provide higher spatial resolution data. In Korea, however, only a few research groups have conducted POPs monitoring using PAS. One of the reasons for the limited application of PAS might be due to a complicated calculation method for air concentration. In this study, therefore, we introduced the principle of polyurethane foam (PUF)-PAS, which has been most widely used in the world, and provided an example of the calculation of air concentration of polycyclic aromatic hydrocarbons (PAHs). As all data tables and equations for this calculation were provided, this method can be used for the conversion of the amount of POPs (ng) in a PUF disk to air concentration ($ng/m^3$).

Experimental Study on Mass Transfer Rate at the Packed Column of Solar Cooling Liquid Desiccant System Using Counter Flow Configuration

  • Hengki R, R.;Choi, K.H.;Yohana, Eflita;Sukmaji, I.C.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.155-161
    • /
    • 2009
  • Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling the latent load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed column and the heat transfer and mass transfer will occur. This proposal is try study the mass transfer and heat transfer inside the packed column of dehumidifier and regenerator systems. And later on, the rates of dehumidification and regeneration that were affected by desiccant flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems.

  • PDF

A Study on the Performance for Heavy-duty Diesel Engine with Intake Air Filter (대형디젤기관에서 자동차 흡기 에어필터 장착에 따른 성능에 관한 연구)

  • Rha, Wan-Yong;Oh, Sang-Ki
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • Air cleaners in all of the automotive engines have been used for decades. In the early 1920's the oil bath type was the popular shape of air cleaners. The air cleaners of the oil wetted bath type were introduced in 1940's. The shape of the dry pleated paper type media was introduced in the 1950's. This trend still continues with new and innovative media being introduced. Engine air cleaners should have effectively removed and reduced harmful contaminants being ingested into engines. This studies show that both, the ingested contaminant size and concentration need to be controlled. This paper com pare and analyze the characteristics over the economics, engine performances and reduction of noises of power-plus air filters with wet paper which were sticked to heavy duty diesel engine.

The Effects of Parameter Changes on the Properties of an Air Spring (공기스프링의 파라미터 변화가 특성 변화에 미치는 영향)

  • Jang, Ji-Seong
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.77-82
    • /
    • 2014
  • The air spring is widely used in various fields such as a suspension system and an anti-vibration system because the natural frequency is kept constant regardless of the change in the load, spring constant is easy to change, and, vibration and shock isolation performance are excellent. The purpose of this study is to derive a nonlinear governing equation of an air spring, to analyze the effect of the various parameters on the dynamic stiffness of the air spring, and, to suggest a more efficient design method of an air spring system. In order to do so, this study investigates the impact of all the parameters that could affect the dynamic stiffness of the air spring while changing the excitation amplitude and the frequency with a developed governing equation.

Design and Performance Prediction of an Air Chamber for Reduction of Water Hammering (수충격 완화용 공기 챔버의 설계 및 성능 예측에 관한 연구)

  • Kang, S.H.;Ryu, H.S.;Park, M.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.57-64
    • /
    • 1992
  • A computer program was developed for the prediction of transient flow in a water supply system. where an air chamber is installed to reduce the water hammering. The governing equations based on a characteristic method are solved using a finite difference method. A design process of an air chamber is shown in the present paper considering the effects of the initial air volume and the discharge coefficients of the orifice on the total volume and over-all performance of the chamber.

  • PDF