• Title/Summary/Keyword: Aliquat 336

Search Result 46, Processing Time 0.02 seconds

Treatment of Nitrogen Oxides in Ambient Air using a Ion-Selective Electrode (대기중 질산화물의 이온 선택성 전극에 의한 처리)

  • 안형환;우인성;강안수;이영순;김윤선
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.40-49
    • /
    • 1990
  • For the determination of polluant NOx in ambient air, nitrate ion-selective electrode(ISE) was made. To comparison of NOx in each method, the nitrate-ISE, NEBA, Orion electrode were used to determinee NOx in ambient air. In this work, the concentration of NOx in ambient air was average 0.06ppm. The results were good agreement with those obtained by each method within a relative error of 3%, Absorbing efficiency of nitrogen oxides in ambient air was good for Alkali solution. The determination of nitrogen oxides in ambient air using the Aliquat 336N-PVC membrane electrode was one of the useful method. The best characteristics of the Aliquat 336N-PVC me,mbrane electrode were obtained with the ion-exchanger concentration level of 6.5-9.1 percent by weight. The optimal membrane composition, was 9.09wt.% of ion-exchanger, 30.95wt.% of PVC, 60.6wt.% of plasticizer (DBP), and 0.5mm of thickness. Under the above condition, the electrode approached the Nernstian slope most closely, and the linear response ranges produced the best results.

  • PDF

Characterization of polymer inclusion membrane containing Aliquat 336 as a carrier

  • Manzak, Aynur;Yildiz, Yasemin;Tutkun, Osman
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.95-102
    • /
    • 2015
  • The presented research is about characterization of Cellulose Triacetate (CTA) based Polymer Inclusion Membranes (PIMs) which incorporated the commercial extractant Aliquat 336, Tributylphosphate (TBP) as modifier and 2-Nitro Phenyl Pentyl Ether (NPPE) as plasticizer, for the preparation of the membranes. Chemical and physical characteristics of the synthesized membranes especially membrane thickness and side difference effects were investigated. Different surface structures and membrane thickness affect the extraction efficiency of membranes. Membrane extraction experiments were studied where the glass-facing surface of the membranes placed next to feed phase and the air-facing surface to stripping phase. The membrane was characterized by means of AFM, FT-IR and SEM.

Improved Membranes for the Extraction of Heavy Metals

  • Xu, Jianying;Shen, Wei;Paimin, Rohani;Wang, Xungai
    • Fibers and Polymers
    • /
    • v.5 no.1
    • /
    • pp.68-74
    • /
    • 2004
  • This work presents a series of experimental tests on new practical approaches in membrane design to improve extraction capacity and rate. We chose an extraction system involving Aliquat 336 as the extractant and Cd(II) as the metal ion to be extracted to demonstrate these new approaches. The core element in the new membrane assembly was the extractant loaded sintered glass filter. This membrane assembly provided a large interface area between the extractant and the aqueous solution containing metal ions. By recycling the aqueous solution through the membrane assembly, the extraction rate was significantly improved. The membrane assembly also offered good extraction capacity.

Use of High Molecular Alkylamines in the Simultaneous Determination of Copper and Cobalt by Spectrophotometry (구리와 코발트의 분광광도법에 의한 정량에 있어서 고분자량 알킬아민의 이용)

  • Chon Han Kim;Chan Ho Jee;Ki Tae Sung;Chang Ung Joung
    • Journal of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.208-214
    • /
    • 1989
  • A method for the simultaneous determination of copper and cobalt by spectrophotometry has been described. The procedure involves the co-extraction of Cu(Ⅱ) and Co(Ⅱ) from 0.3M HCl into methyl isobutyl ketone as the ion-pairs formed between their thiocyanate complexes and high molecular alkylamines such as Amberlite LA1, Alamine 336, and Aliquat 336. The extract shows the color development to have the maximum absorbances at two different wavelengths i.e., 480 nm for copper and 625 nm for cobalt. Since the spectra of the ion-pairs overlap each other, two simultaneous equations are used to obtain the concentrations from absorbances. Even small amount of Fe(Ⅲ) and Ni(Ⅱ) interferes with the determination of copper. The results of the analysis of samples are in good agreement with the results determined by separate methods within RSD 5.9%.

  • PDF

Solvent Extraction of Co(II) and Cu(II) from Hydrochloric Acid Solution of Spent Lithium-ion Batteries Containing Li(I), Mn(II), and Ni(II) (Li(I), Mn(II) 및 Ni(II)를 함유한 폐리튬 이온 배터리의 염산침출용액에서 Co(II) 및 Cu(II)의 용매 추출)

  • Le, Minh Nhan;Lee, Man Seung
    • Resources Recycling
    • /
    • v.29 no.5
    • /
    • pp.73-80
    • /
    • 2020
  • In order to develop a process for the recovery of valuable metals from spent LiBs, solvent extraction experiments were performed to separate Cu(II) and/or Co(II) from synthetic hydrochloric acid solutions containing Li(I), Mn(II), and Ni(II). Commercial amines (Alamine 336 and Aliquat 336) were employed and the extraction behavior of the metals was investigated as a function of the concentration of HCl and extractants. The results indicate that HCl concentration affected remarkably the extraction efficiency of the metals. Only Cu(II) was selectively at 1 M HCl concentration, while both Co(II) and Cu(II) was extracted by the amines when HCl concentration was higher than 5 M, leaving the other metal ions in the raffinate. Therefore, it was possible to selectively extract either Cu(II) or Co(II)/Cu(II) by adjusting the HCl concentration.

Stability of concentrated Colloidal Liquid Aphrons containing a quaternary ammonium salt in the continuous phase (사차 암모늄 염을 함유하는 농축된 콜로이드 액상 에이프런의 연속상에서의 안정성)

  • Hahm, Hyung Chul;Hong, Won Hi;Lee, Choul Ho
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.291-297
    • /
    • 2001
  • In this study, the stability of concentrated colloidal liquid aphrons (CLAs) containing Aliquat 336 was measured. CLAs in the continuous phase are stabilized by water-soluble surfactant and oil-soluble surfactant. To compare the stability of CLAs, half-life was introduced. According to the change of state of solution, the rate of break-up of concentrated CLAs changed rigorously at critical coagulation concentration. Critical coagulation concentration was measured with changing pH. The effects of ionic strength and concentration of Sodium Dodecyl Benzene Sulfonate (SDBS) on the stability of concentrated CLAs in the continuous phase were also investigated.

  • PDF

Precious Metals Extraction Processing in Chloride Media by Using Ionic Liquids as Novel Extractant Systems

  • Kumar, Jyothi Rajesh;Choi, In-Hyeok;Lee, Jin-Young
    • Korean Chemical Engineering Research
    • /
    • v.55 no.4
    • /
    • pp.503-509
    • /
    • 2017
  • The present experimental study proposed two ionic liquids (ILs) namely [Aliquat 336] [$HSO_4$] (prepared and characterized at our laboratory) and Cyphos 101 IL (supplied by Cytec Company) dissolved in two different diluents such as DCM (di-chloro-methane) and toluene applied for PMs extraction. The first IL [Aliquat 336] [$HSO_4$] prepared and confirmed the formation of final product by using FT-IR and TGA studies. The primary experiment in solvent extraction processing is kinetic effect; 0 to 30 time varied for PMs by using two ILs and confirmed the optimized extraction equilibrium time. This study was conducted for PMs (Pt, Rh and Cu) extraction and separation from each other by using proposed ILs. This is the primary study of the utilizing green solvents such as ILs as an extractant system for Pt, Rh and Cu extraction and possible separation.

Recovery of Pt from the Chloride Leaching Solution of Spent Catalysts by using Column Extractor (폐촉매(廢觸媒) 염산침출액(鹽酸浸出液)에서 컬럼형 추출기(抽出器)에 의한 백금(白金) 회수(回收))

  • Sun, Pan-Pan;Lee, Man-Seung
    • Resources Recycling
    • /
    • v.22 no.6
    • /
    • pp.26-32
    • /
    • 2013
  • In order to recover Pt from the hydrochloric acid leaching solution of spent catalysts, bench scale Karr reciprocating column was employed. At an optimum flow rate and vibration frequency, iron and Pt was completely extracted by using TBP and Aliquat 336. At the same vibration frequency, iron and Pt was completely stripped by HCl and $HClO_4$ after adjusting the flow rate. In the case of extraction of HCl from the raffinate with TEHA, it was difficult to maintain the stability of the column extractor. A comparison of the operation results between column extractor and mixer-settler is reported.

Solvent Extraction of Hydrochloric Acid Using Commercial Extractants and Synthesized Ionic Liquids (상용화 추출제 및 이온성액체에 의한 염산의 용매추출)

  • Nguyen, Viet Nhan Hoa;Lee, Man Seung
    • Resources Recycling
    • /
    • v.29 no.6
    • /
    • pp.79-87
    • /
    • 2020
  • The extraction and stripping of HCl from aqueous solutions by commercial extractants like LIX 63 and its mixture with TEHA/ Cyanex 923/ Aliquat 336 and ionic liquids like ALi-SCN, ALi-PC in kerosene was investigated. Among these extractants, ALi-PC showed the best extraction effectivity (above 80%), but it was difficult to strip HCl from the loaded phase. Although the extraction percentage of HCl by LIX 63 was not high, the stripping performance was above 81%. The addition of octanol to the organic phase led to negative effect on the extraction performance of HCl. The addition of C2H5OH into aqueous solutions significantly increased the extraction and stripping percentage of HCl by LIX 63, ALi-PC and ALi-SCN.