• Title/Summary/Keyword: Alignment Measurement

Search Result 338, Processing Time 0.028 seconds

Measurement Methods of Lower Extremity Alignment in Static Posture (정적 자세에서 하지정렬 측정방법에 관한 고찰)

  • Kong Hee-Kyung;Cho Hyun-Rae;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • We need to study about lower extremity alignment because the structure dictates the function of lower extremity. Through lower extremity alignment assessment in static posture, we recognize abnormal structural conditions which could affect dynamic motion such as gait. To evaluate of lower extremity alignment provide so many useful information, but method of measurement is so limited. Therefore, this review will assist understanding for measurement of lower extremity alignment in static posture. From now on study about the objective measurement method must be achieved much more in physical therapy.

  • PDF

A New Approach for SINS Stationary Self-alignment Based on IMU Measurement

  • Zhou, Jiangbin;Yuan, Jianping;Yue, Xiaokui
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.355-359
    • /
    • 2006
  • For the poor observability of azimuth misalignment angle and east gyro drift rate of the traditional initial alignment, a bran-new SINS stationary fast self-alignment approach is proposed. By means of analyzing the characteristic of the strapdown inertial navigation system (SINS) stationary alignment seriously, the new approach takes full advantage of the specific force and angular velocity information given by inertial measurement unit (IMU) instead of the mechanization of SINS. Firstly, coarse alignment algorithm is presented. Secondly, a new fine alignment model for SINS stationary self-alignment is derived, and the observability of the model is analysed. Then, a modified Sage-Husa adaptive Kalman filter is introduced to estimate the misalignment angles. Finally, some computer simulation results illustrate the efficiency of the new approach and its advantages, such as higher alignment accuracy, shorter alignment time, more self-contained and less calculation.

  • PDF

A Transfer Alignment Considering Measurement Time-Delay and Ship Body Flexure (측정치 시간지연과 선체의 유연성을 고려한 전달정렬 기법)

  • Lim, You-Chol;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.225-233
    • /
    • 2001
  • This paper deals with the transfer alignment problem of SDINS(StrapDown Inertial Navigation System) subjected to roll and pitch motions of the ship. Specifically, to reduce alignment errors induced by measurement time-delay and ship body flexure, an error compensation method is suggested based on delay state augmentation and DCM(Direction Cosine Matrix) partial matching. A linearized error model for the velocity and attitude matching transfer alignment system is first derived by linearizing the nonlinear measurement equation with respect to its time delay and augmenting the delay state into the conventional linear state equations. And then DCM partial matching is properly combined to reduce effects of a ship's Y axis flexure. The simulation results show that the suggested method is effective enough resulting in considerably less azimuth alignment errors.

  • PDF

Measurement Time-Delay Error Compensation For Transfer Alignment

  • Lim, You-Chol;Song, Ki-Won;Joon Lyou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.486-486
    • /
    • 2000
  • This paper is concerned with a transfer alignment method for the SDINS(StrapDown Inertial Navigation System) under ship motions. Major error sources of transfer alignment are data transfer time-delay, lever-arm velocity and ship body flexure. Specifically, to reduce alignment errors induced by measurement time-delay effects, the error compensation method through delay state augmentation is suggested. A linearized error model for the velocity and attitude matching transfer alignment system is first derived by linearizing the nonlinear measurement equation with respect to its time delay and augmenting the delay state into the conventional linear state equations. And then it is shown via observability analysis and computer simulations that the delay state can be estimated and compensated during ship motions resulting in considerably less alignment errors.

  • PDF

Modeling Alignment Experiment Errors for Improved Computer-Aided Alignment

  • Kim, Yunjong;Yang, Ho-Soon;Song, Jae-Bong;Kim, Sug-Whan;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.525-532
    • /
    • 2013
  • Contrary to the academic interests of other existing studies elsewhere, this study deals with how the alignment algorithms such as sensitivity or Differential Wavefront Sampling (DWS) can be better used under effects from field, compensator positioning and environmental errors unavoidable from the shop-floor alignment work. First, the influences of aforementioned errors to the alignment state estimation was investigated with the algorithms. The environmental error was then found to be the dominant factor influencing the alignment state prediction accuracy. Having understood such relationship between the distorted system wavefront caused by the error sources and the alignment state prediction, we used it for simulated and experimental alignment runs for Infrared Optical System (IROS). The difference between trial alignment runs and experiment was quite close, independent of alignment methods; 6 nm rms for sensitivity method and 13 nm rms for DWS. This demonstrates the practical usefulness and importance of the prior error analysis using the alignment algorithms before the actual alignment runs begin. The error analysis methodology, its application to the actual alignment of IROS and their results are described together with their implications.

Self-Alignment/Navigation Performance Analysis in the Accelerometer Resonance State Generated by Dither Motion of Ring Laser Gyroscope in Laser Inertial Navigation System (레이저 관성항법장치에서 링레이저 자이로 디더 운동에 의한 가속도계 공진이 자체 정렬/항법 성능에 미치는 영향 분석)

  • Kim, Cheonjoong;Lim, Kyungah;Kim, Seonah
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.577-590
    • /
    • 2021
  • In this paper, we theoretically analyzed the self-alignment/navigation performance in the accelerometer resonance state generated by dither motion of ring laser gyroscope in LINS and verified it through simulation. As a result of analysis, it is confirmed that the amplitude of the accelerometer measurement amplified in the accelerometer resonance state is decreased in the process of sampling per the navigation calculation period and that frequency is changed by the aliasing effect too. It was also analysed that the attitude error in self-alignment is determined by the amplitude/frequency of the accelerometer measurement, the gain of the self-alignment loop, and the velocity and position error in the navigation is determined by the amplitude/frequency/phase error of the accelerometer measurement. This analysis and simulation results show that the self-alignment and navigation performance is not be degraded only when the amplification factor of the accelerometer measurement in the accelerometer resonance state is 3 or less

Compensation Technique of Measurement Time Delay in Transfer Alignment Using the Double Moving Window Buffer (이중 Moving Window 버퍼 기반 전달정렬 측정치 시간지연 보상기법)

  • Kim, Cheon-Joong;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.684-693
    • /
    • 2011
  • Measurement time delay in the transfer alignment is very important. It has been well known that the time delay degrades the alignment performance and makes some navigation errors on the transfer alignment of slave INS(SINS). Therefore there are many schemes to eliminate that time delay but the compensation technique through the estimation by Kalman filter through modeling the time delay as a random constant is generally used. In the case of change over measurement time delay or the large measurement time delay, estimation performance in the existing compensation technique is degraded because model of time delay is not correct any more. In this paper, we propose the method to keep the time delay almost constant even though in the abnormal communication state and very small through feedback compensation using double buffer. Double buffer consists of two moving window to temporarily store measurements from master INS and slave INS in real time.

Measurement methodology for the alignment accuracy of wafer stepper (웨이퍼 스텝퍼의 정렬정확도 측정에 관한 연구)

  • Lee, Jong-Hyun;Jang, Won-Ick;Lee, Yong-Il;Kim, Doh-Hoon;Choi, Boo-Yeon;Nam, Byung-Ho;Kim, Sang-Cheol;Kim, Jin-Hyuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.1
    • /
    • pp.150-156
    • /
    • 1994
  • To meet the process requirement of semiconductor device manufacturing, it is necessary to improve the alignment accuracy in exposure equipments. We developed the excimer laser stepper and will describe the methodology for alignment measurement and experimental results. Our wafer alignment system consists of off-axis optics, TTL(Through The Lens) optics and high precision stage. Off-axis alignment utilizes the image processing and /or diffraction from thealign marks of off-centered chip area. On the other hand, TTL alignment can be used for the die-by-die alignment using dual beam interferometry. When only off-axis alignment was used, the experimental alignment error(lml+3 .sigma. ) was 0.26-0.29 .mu. m, and will be reduced down to 0.15 .mu. m by adding TTL alignment.

  • PDF

통신방송위성 안테나 얼라인먼트 측정

  • Yoon, Yong-Sik;Park, Hong-Chul;Son, Young-Seon;Lee, Byoung-Gi
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.117-125
    • /
    • 2004
  • The three-dimensional precision measurement technology for industrial product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes a range alignment method of parabolic antenna to RF probe in the near field range by using the theodolite system. The range alignment of the Ku-band and Ka-band antennas has been accomplished within the requirements, ±1 mm and ±$0.05^{circ}$.

  • PDF