• Title/Summary/Keyword: Aligner

Search Result 83, Processing Time 0.027 seconds

A Wafer Alignment Method and Accuracy Evaluation (웨이퍼 정렬법과 정밀도 평가)

  • Park, Hong-Lae;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.9
    • /
    • pp.812-817
    • /
    • 2002
  • This paper presents a development of high accuracy aligner and describes a method to find the orientation of a substantially circular disk shaped wafer with at least one flat region on an edge thereof. In the developed system, the wafer is spun one 360 degree turn on a chuck and the edge position is measured by a linear array to obtain a set of data points at various wafer orientation. The rotation axis may differ from wafer center by an unknown eccentricity. The flat angle is found by fitting a cosine curve to the actual data to obtain a deviation. The maximum deviation is then corrected for errors due to a finite number of data points and wafer eccentricity by calculating an adjustment angle from data points on the wafer fiat. After determining the flat angle the wafer is spun to the desired orientation. The wafer eccentricity can be calculated from four of the data points located away from the flat edge region. and the wafer is then centered.

A digital frame phse aligner in SDH-based transmission system (SDH 동기식 전송시스템의 디지철 프레임 위상 정열기)

  • 이상훈;성영권
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.12
    • /
    • pp.10-18
    • /
    • 1997
  • The parallel trabutary signals in the SDH-based transmission system have the frame phase skew due to uneven transmission delays in the data and the clock path. This phase skew must be eliminated prior to synchronously multiplexing process. A new twenty-four channel, 51.84Mb/s DFPA(Digital Frame Phase Aligner) has been designed and fabricated in 0.8.mu.m CMOS gate array. This unique device phase-aligns the skewed input signals with refernce frame synchronous signal and reference clok for subsequent synchronous multiplexing process. the performance of fabricated device is evaluated by the STM-16 transmission system and DS-3 meansurement set. The frame phase margin of +2/-3 bit periods has been demonstrated.

  • PDF

A Study on the Design and Development of Automatic Optical Fiber Aligner (자동 광섬유 정렬 장치의 설계 및 제작에 관한 연구)

  • Kim, Byung-Hee;Uhm, Chul;Choi, Young-Suk
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.241-249
    • /
    • 2002
  • Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super precision technology in sub-micron units is required for optical axis adjustment. We developed the automatic optical fiber by image processing and automatic loading system. we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10{\mu}m$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up and fiber input array and waveguide chip formed in line by automatic.

  • PDF

Physical properties of thermoplastic material for clear aligners (투명 장치의 열가소성 재료의 올바른 이해)

  • Cha, Jung-Yul
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.542-550
    • /
    • 2016
  • Recent technological advance have greatly expanded the application of invisible orthodontic treatment using clear thermoplastic materials. However, the final outcomes using clear aligner system do not achieve the level of final goal frequently, which results in case refinement, midcourse correction, or fixed orthodontic treatment. Therefore, mechanical properties of thermoplastic materials should be considered to improve the quality of outcomes. The purposes of this special article were to evaluate the force and stress depending on the materials, deflection and thickness of thermoplastic materials and to evaluate the mechanical properties of thermoplastic materials after repeated loading. Thickness and amount of deflection rather than products and materials showed the largest effect on force and stress. In all products, at least 159 gf of force was required for more than 1.0 mm deflection or when materials with 1.0 mm thickness were deflected. Orthodontic forces delivered by thermoplastic materials depend on the materials, thickness, amount of activation, and intra-oral condition. Proper thickness of thermoplastic materials and deflection level of tooth movement should be decided for the efficient and physiologic tooth movement.

  • PDF

Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor

  • Li, Xiaowei;Ren, Chaochao;Wang, Zheyao;Zhao, Pai;Wang, Hongmei;Bai, Yuxing
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.65-72
    • /
    • 2016
  • Objective: The purposes of this study were to measure the orthodontic forces generated by thermoplastic aligners and investigate the possible influences of different activations for lingual bodily movements on orthodontic forces, and their attenuation. Methods: Thermoplastic material of 1.0-mm in thickness was used to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations for lingual bodily movements of the maxillary central incisor. The orthodontic force in the lingual direction delivered by the thermoplastic aligners was measured using a micro-stress sensor system for the invisible orthodontic technique, and was monitored for 2 weeks. Results: Orthodontic force increased with the amount of activation of the aligner in the initial measurements. The attenuation speed in the 0.6 mm group was faster than that of the other groups (p < 0.05). All aligners demonstrated rapid relaxation in the first 8 hours, which then decreased slowly and plateaued on day 4 or 5. Conclusions: The amount of activation had a substantial influence on the orthodontic force imparted by the aligners. The results suggest that the activation of lingual bodily movement of the maxillary central incisor should not exceed 0.5 mm. The initial 4 or 5 days is important with respect to orthodontic treatment incorporating an aligner.

Analysis of Mechanical Properties of Polymer Material for Clear Aligner using Uniaxial Tensile Test (일축인장시험을 통한 투명교정장치용 고분자 소재의 역학적 특성 분석)

  • Jeong, Ji-Young;Je, Tae-Jin;Jeon, Eun-chae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.5
    • /
    • pp.64-69
    • /
    • 2018
  • Clear aligners are popular in the field of dental orthodontic treatment because they offer a discreet alternative to braces due to their use of transparent materials. They are formed from flat transparent polymer materials by hot pressed molding. It is necessary to know the mechanical properties of the polymer materials to be able to form the exact shapes of the clear aligners. However, this information is not publicly available. In this study, we present a method to reliably measure the mechanical properties of clear aligner polymer materials and analyze the factors effecting these mechanical properties. First, we surveyed standards related to the mechanical properties of polymer materials to obtain reliable data. Consequently, ISO 527 was selected for use in this study because of the size and thickness of the flat transparent polymer material. The uniaxial tensile tester was constructed and it was verified whether displacement of a crosshead could be regarded as a displacement of gauge-length by optical analysis. Uniaxial tensile tests of three thicknesses from three different companies were performed and each engineering stress-strain curve was measured. Tensile strengths and elastic moduli were obtained by analysis of the stress-strain curves. The tensile strength and elastic modulus of ISO 527 was found to be approximately 50MPa and 2.3GPa, respectively. Both values showed material and thickness dependency.

Treatment of anterior open bites using non-extraction clear aligner therapy in adult patients

  • Suh, Heeyeon;Garnett, Bella Shen;Mahood, Kimberly;Mahjoub, Noor;Boyd, Robert L.;Oh, Heesoo
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.210-219
    • /
    • 2022
  • Objective: The purpose of this study was to examine the effectiveness and mechanism of clear aligner therapy for the correction of anterior open bite in adult nonextraction cases. Methods: Sixty-nine adult patients with anterior open bite were enrolled and classified into Angle's Class I, II, and III groups. Fifty patients presented with skeletal open bite (mandibular plane angle [MPA] ≥ 38°), whereas 19 presented with dental open bite. Fifteen cephalometric landmarks were identified before (T1) and after (T2) treatment. The magnitudes of planned and actual movements of the incisors and molars were calculated. Results: Positive overbite was achieved in 94% patients, with a mean final overbite of 1.1 ± 0.8 mm. The mean change in overbite was 3.3 ± 1.4 mm. With clear aligners alone, 0.36 ± 0.58 mm of maxillary molar intrusion was achieved. Compared with the Class I group, the Class II group showed greater maxillary molar intrusion and MPA reduction. The Class III group showed greater mandibular incisor extrusion with no significant vertical skeletal changes. Conclusions: Clear aligners can be effective in controlling the vertical dimension and correcting mild to moderate anterior open bite in adult nonextraction cases. The treatment mechanism for Class III patients significantly differed from that for Class I and Class II patients. Maxillary incisor extrusion in patients with dental open bite and MPA reduction with mandibular incisor extrusion in patients with skeletal open bite are the most significant contributing factors for open bite closure.

Use of Head Posture Aligner to improve accuracy of frontal cephalograms generated from cone-beam CT scans (3차원 콘빔CT 영상에서 형성한 2차원 정모두부방사선사진영상의 정확도 증진을 위한 두부자세재현기의 효과)

  • Sun, Min-Kyu;Uhm, Gi-Soo;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.289-299
    • /
    • 2009
  • Objective: The purpose of the present study was to evaluate the effectiveness of the use of Head Posture Aligner (HPA) during cone-beam computed tomography (CBCT) scan in generation of frontal cephalograms using 3D CBCT images. Methods: CBCT scans and frontal cephalograms were made in 30 adult individuals. While a couple of CBCT scan was made for one subject, one was made with conventional method, without use of HPA, the other was acquired with the use of HPA. After creation of virtual frontal cephalogram from each 3D CBCT image, it was traced and compared with the tracing of real frontal cephalogram. Results: In the comparison of the measurements, the virtual cephalograms with the use of HPA did not show statistically significant differences with the real cephalograms whereas the virtual cephalograms without the use of HPA presented significant differences with real cephalograms in many measurements. In the correlation analysis with the measurements of the real cephalograms, the virtual cephalograms with the use of HPA showed higher correlations in all measurements than the virtual cephalograms without the use of HPA. Conclusions: Measurements from CBCT-generated cephalograms become similar to those from real cephalograms with the use of HPA during CBCT scan. Thus, the use of HPA is suggested during the CBCT scan in order to construct accurate virtual frontal cephalograms using 3D CBCT images.

Redetermination of curve number using genetic algorithm and CN aligner equation (유전자 알고리즘과 CN Aligner 공식을 이용한 유출곡선지수 재산정)

  • Park, Dong-Hyeok;Kang, Doo-Sun;Ahn, Jae-Hyun;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.373-380
    • /
    • 2016
  • The NRCS-CN (Natural Resources Conservation Service-Curve Number) method has been practically applied for estimating the effective precipitation. However, there are no criteria which reflect the geographic characteristics of Korea having more than 70% of mountainous and rice paddy areas, leading to significant errors in runoff calculation. Thus, it is required to estimate the runoff curve number considered Korea land use classification, however there are practical difficulties to conduct the accurate research and experimentation. In this study, after selecting target areas (urban, agriculture, forest), we performed the runoff analysis to redetermine CN values for the selected basins. To do this, curve numbers for soil type A were estimated using genetic algorithm, and then curve numbers for soil type (B, C, D) were estimated using CN aligner equation. Comparing the initial curve numbers with the estimated curve numbers, it was observed that the slightly differences at Chunwang(0), Choonyang(-1), Janggi(-3). Through the above process, this study proposed new curve numbers to reflect observed rainfall-runoff.