• Title/Summary/Keyword: Aliasing error

Search Result 26, Processing Time 0.022 seconds

An Improved Design Method of FIR Quadrature Mirror-Image Filter Banks (개선된 FIR QMF 뱅크의 설계 방법)

  • 조병모;김영수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.213-221
    • /
    • 2004
  • A new method for design of two-channel finite-impulse response(FIR) quadrature mirror-image filter(QMF) banks with low reconstruction delay using weighting function is proposed. The weighting function used in this paper is calculated from the previous updated filter coefficients vector which is adjusted from iteration to iteration in the design of QMF banks. In this paper, passband and stopband edge frequency are used in design of QMF banks with low delay characteristic in time domain instead of specific frequency interval where the artifacts occur in conventional design method. The investigation of specific frequency interval where artifacts occur can not be required by using passband and stopband edge frequency. Some comparisons of performance are made with other existing design method to demonstrate the proposed method for QMF bank design. and it was observed that the proposed method using the weighted function and passband and stopband edge frequency improves the peak reconstruction error by 0.001 [dB], the peak-to-peak passband ripple by 0.003[dB], SNR with a white noise by 7[dB] and SNR with a step input by 32[dB], but with a reduction of the computational efficiency because of updating the weighting function over the conventional method in Ref [11].

Projected Image Reconstruction Using Higher Order B-Spline (사영된 영상의 고차원 비-스플라인을 이용한 복원법)

  • Kim Sung-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.6
    • /
    • pp.97-108
    • /
    • 2005
  • In this paper a method of reconstructing a desired image through the geometrical transformation and the interpolation techniques is presented by comparing different interpolation schemes. Several different interpolation schemes are compared with respect to the amount of error that is the difference between the original and the reverse-projective transformed images. Higher ordered B-spline interpolation turned to be superior to other techniques in reconstructing the image which is desired to be close to the unskewed image as much as possible. In the results, this paper demonstrates that the reverse projection using the higher ordered B-spline interpolation is superior to those conventional interpolation methods, linear, cubic spline for reconstructing image. In experiments, the error decreases as the order of B-spline increases. The proposed technique is useful for various practical and theoretical applications in the area of satellite, medical, and commercial image processing.

  • PDF

Subpixel Shift Estimation in Noisy Image Using Iterative Phase Correlation of A Selected Local Region (잡음 영상에서 국부 영역의 반복적인 위상 상관도를 이용한 부화소 이동량 추정방법)

  • Ha, Ho-Gun;Jang, In-Su;Ko, Kyung-Woo;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.103-119
    • /
    • 2010
  • In this paper, we propose a subpixel shift estimation method using phase correlation with a local region for the registration of noisy images. Phase correlation is commonly used to estimate the subpixel shift between images, which is derived from analyzing shifted and downsampled images. However, when the images are affected by additive white Gaussian noise and aliasing artifacts, the estimation error is increased. Thus, instead of using the whole image, the proposed method uses a specific local region that is less affect by noises. In addition, to improve the estimation accuracy, iterative phase correlation is applied between selected local regions rather than using a fitting function. the restricted range is determined by analyzing the maximum peak and the two adjacent values of the inverse Fourier transform of the normalized cross power spectrum. In the experiments, the proposed method shows higher accuracy in registering noisy images than the other methods. Thus, the edge-sharpness and clearness in the super-resolved image is also improved.

Input-Output Gains of Linear Periodic Time-Varying Systems with Applications to Multirate Signal Processing (다중비 신호처리에 적용한 선형 주기적 시변 시스템의 입출력 이득)

  • 이상철;박계원
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.963-969
    • /
    • 2000
  • In this paper, we define two input-output gains of linear periodic time-varying systems. One is the ratio of output with worst-case l2-norm over all inputs with unit 12-norm. It denotes G($\iota_2,\iota_2$.The other is the ratio of output with worst-case RMS value over all inputs with unit RMS value. It denotes G(RMS, RMS) .It is fact that these two gains are equivalent for linear time-invariant system. In this paper, we prove these two gains are also equivalent for linear periodic time-varying system. In addition, the relationship between two method of obtaining the generalized frequency responses for linear periodic time-varying system is derived. Finally, we apply the defined input-output gains to M-channel filter-bank which is multi-rate signal Processing system, used to speech coding. In the filter-bank, generally, aliasing distortion, magnitude distortion, and phase distortion are present. It is shown that these are kept small if the filter-bank is designed by a method that optimizes the gain G($\iota_2,\iota_2$ of an error system.

  • PDF

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

Minimal Sampling Rate for Quasi-Memoryless Power Amplifiers (전력증폭기 모델링을 위한 최소 샘플링 주파수 연구)

  • Park, Young-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.10
    • /
    • pp.185-190
    • /
    • 2007
  • In this paper, minimum sampling rates and method of nonlinear characterization were suggested for low power, quasi-memoryless PAs. So far, the Nyquist rate of the input signal has been used for nonlinear PA modeling, and it is burdening Analog-to-digital converters for wideband signals. This paper shows that the input Nyquist rate sampling is not a necessary condition for successful modeling of quasi-memoryless PAs. Since this sampling requirement relives the bandwidth requirements for Analog-to-digital converters (ADCs) for feedback paths in digital pre-distortion systems, relatively low-cost ADcs can be used to identify nonlinear PAs for wideband signal transmission, even at severe aliasing conditions. Simulation results show that a generic memoryless nonlinear RF power amplifier with AMAM and AMPM distortion can be successfully identified at any sampling rates. Measurement results show the modeling error variation is less than 0.8dB over any sampling rates.