• Title/Summary/Keyword: Alcohol gas sensor

Search Result 41, Processing Time 0.027 seconds

A Step-wise Elimination Method Based on Euclidean Distance for Performance Optimization Regarding to Chemical Sensor Array (유클리디언 거리 기반의 단계적 소거 방법을 통한 화학센서 어레이 성능 최적화)

  • Lim, Hea-Jin;Choi, Jang-Sik;Jeon, Jin-Young;Byu, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.258-263
    • /
    • 2015
  • In order to prevent drink-driving by detecting concentration of alcohol from driver's exhale breath, twenty chemical sensors fabricated. The one of purposes for sensor array which consists of those sensors is to discriminate between target gas(alcohol) and interference gases($CH_3CH_2OH$, CO, NOx, Toluene, and Xylene). Wilks's lambda was presented to achieve above purpose and optimal sensors were selected using the method. In this paper, step-wise sensor elimination based on Euclidean distance was investigated for selecting optimal sensors and compared with a result of Wilks's lambda method. The selectivity and sensitivity of sensor array were used for comparing performance of sensor array as a result of two methods. The data acquired from selected sensor were analyzed by pattern analysis methods, principal component analysis and Sammon's mapping to analyze cluster tendency in the low space (2D). The sensor array by stepwise sensor elimination method had a better sensitivity and selectivity compared to a result of Wilks's lambda method.

The Applications of Sol-Gel Derived Tin Oxide Thin Films

  • Park, Sung-Soon;John D. Mackenzie
    • The Korean Journal of Ceramics
    • /
    • v.2 no.1
    • /
    • pp.1-10
    • /
    • 1996
  • Transparent conducting $SnO_2$-based thin films have been coated on float substrates such as fused quartz, and ceramic fiber cloths such as the Nexel and E-glass cloth from tin alkoxides by the sol-gel technique. Also, thin films of alternating layers of $SnO_2$ and $SiO_2$ have been fabricated by dip coating. The sheet resistance and average visible transmittance of the films were investigated in the aspect of the applications as transparent electrodes such as liquid crystal displays, photo-detectors and solar cells. The Nextel and E-glass cloths coated with antimony-doped tin oxide (ATO) had sheet resistance of as low as $20 \;ohm/{\Box}$ and $120ohm/\;{\Box}$, respectively. The promotion effects of additives as $La_2O_3$ and Pt on the ethanol gas sensing properties of the films were investigated in the aspects of the applications as an alcohol sensor and a breath alcohol checker. Possible evidence of quantum well effects in the oxide multilayers of $SnO_2$ and $SiO_2$ was investigated.

  • PDF

Characteristics of a Metal-loaded SnO2/WO3 Thick Film Gas Sensor for Detecting Acetaldehyde Gas

  • Jun, Jae-Mok;Park, Young-Ho;Lee, Chang-Seop
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1865-1872
    • /
    • 2011
  • This study investigates the sensitivity of a gas sensor to volatile organic compounds (VOCs) at various operating temperatures and catalysts. Nano-sized powdered $WO_3$ prepared by sol-gel and chemical precipitation methods was mixed with various metal oxides. Next, transition metals (Pt, Ru, Pd, and In) were doped on the surface of the mixture. Metal-$WO_3$ thick films were prepared using the screen-printing method. The physical and chemical properties of the films were studied by SEM/EDS, XRD, and BET techniques. The measured sensitivity to VOCs is defined as the ratio ($R_a/R_g$) of resistance ($R_{air}$) of $WO_3$ film in the air to resistance ($R_{gas}$) of $WO_3$ film in a VOCs test gas. The sensitivity and selectivity of the films were tested with various VOCs such as acetaldehyde, formaldehyde, methyl alcohol, and BTEX. The thick $WO_3$ film containing 1 wt % of Ru and 5 wt % of $SnO_2$ showed the best sensitivity and selectivity to acetaldehyde gas at an operating temperature of 300 $^{\circ}C$.

Investigation of Chemical Sensor Array Optimization Methods for DADSS

  • Choi, Jang-Sik;Jeon, Jin-Young;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Nowadays, most major automobile manufacturers are very interested, and actively involved, in developing driver alcohol detection system for safety (DADSS) that serves to prevent driving under the influence. DADSS measures the blood alcohol concentration (BAC) from the driver's breath and limits the ignition of the engine of the vehicle if the BAC exceeds the reference value. In this study, to optimize the sensor array of the DADSS, we selected sensors by using three different methods, configured the sensor arrays, and then compared their performance. The Wilks' lambda, stepwise elimination and filter method (using a principal component) were used as the sensor selection methods [2,3]. We compared the performance of the arrays, by using the selectivity and sensitivity as criteria, and Sammon mapping for the analysis of the cluster type of each gas. The sensor array configured by using the stepwise elimination method exhibited the highest sensitivity and selectivity and yielded the best visual result after Sammon mapping.

Implementation of a Portable Breathalyzer Using MEMS Sensor (MEMS 센서를 활용한 휴대용 음주 측정기 구현)

  • Ju, Yong-Wan;Park, Jang-Sik;Kim, Hyun-Tae;Yu, Yun-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.779-781
    • /
    • 2011
  • Drinking is one of most prominent causes for social problems like domestic violence, drinking and driving, and health problems. If who drunken can check promptly how much blood alcohol content, abstain from drunken driving or successive drinking schedule. In this paper, implementation of digital portable breathalyzer using semiconductor gas sensor based on MEMS were suggested. A small size micro controller with low power and surface mountable, ATMEGA48 can control semiconductor gas sensor digitally and display the value of alcohol concentration on LED.

  • PDF

The effect of binder in SWNT solution to gas selectivity of CNT-based gas sensors (가스센서로써 탄소나노튜브 용액속에 바인더가 가스 선택성에 미치는 효과)

  • Lee, Ho-Jung;Gam, Byung-Min;Choi, Young-Min;Kim, Seong-Jeen
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.404-405
    • /
    • 2008
  • In this work, we investigated the effect of the functionalized SWNT-polymer composites for increasing sensitivity and imparting selectivity to nanotube sensors. To do this, CNT -based gas sensors were fabricated with two types of dispersed SWNT solution involving different polymer resin of TEOS (Tetraethyl orthosilicate) or MTMS (Methyl trimethoxysilane) which is blended to adhere to substrate well. As the surfaces of TEOS and MTMS surrounding SWNTs remain functionalized to -OH and $-CH_3$ groups respectively after hardening, gas adsorption will be affected differently according to the type of gases. In the experiment, we examined the response of electrical conductance for alcohol vapour gas. As the result, the conductance in the sensors using TEOS decreased considerably while that of MTMS was nearly invariable.

  • PDF

C-V Response Properties of Alcohol Vapor Sensors Based on Porous Silicon (다공질 실리콘 알코올 가스 센서의 C-V 응답 특성)

  • Kim, Seong-Jeen;Lee, Sang-Hoon;Choi, Bok-Gil;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.592-597
    • /
    • 2004
  • Porous silicon(PS) has received much attention as a sensitive material of chemical sensors because of its large internal surface area. In this work, we fabricated gas-sensing devices based on the porous silicon layer which could be applicable to the measurement of blood alcohol content(BAC), and estimated their electrical properties. The structure of the sensor is similar to an MIS (metal-insulator-semiconductor) diode and consists of thin Au/oxidized PS/PS/p-Si/Al, where the p-Si substrate is etched anisotropically to reduce the thickness. We measured C-V curves from two types of the samples with the PS layer treated by the different anodization current density of 60 or 100 mA/cm$^2$, in order to compare the sensitivity. As a result, the magnitude and variation of capacitances from the devices with the PS formed under the current density of 100 mA/cm$^2$ were found to be more detectable due to the larger internal surface.

Fabrication and characteristics of alcohol sensor using Fe2O3 (Fe2O3후막을 이용한 alcohol sensor 제작 및 감응특성)

  • Lee, Y.S.;Song, K.D.;Lee, S.M.;Shim, C.H.;Choi, N.J.;Joo, B.S.;Lee, D.D.;Huh, J.S.
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.77-83
    • /
    • 2002
  • In order to get low cost and portability, semiconductor gas sensor need to have low operating temperature and high sensitivity. $Fe_2O_3$ based sensors which were doped with metal oxide catalysts($MoO_3$, $V_2O_5$, $TiO_2$, and CdO) were fabricated by screen printing method. To improve electrical stability of sensors, the $Fe_2O_3$ sensors were annealed in $N_2$ at $700^{\circ}C$ for 2 hours. The $V_2O_5$ doped $Fe_2O_3$ sensor showed about $80{\sim}90%$ sensitivity at alcohol 1,000 ppm and have good selectivity to hydrocarbon gas and tobacco odors. The fabricated sensor and PIC-chip were employed for portable alarm system.

Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde (Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF